The effect of finish line curvature on marginal fit of all-ceramic CAD/CAM crowns and metal-ceramic crowns

被引:0
|
作者
Tao, Jianxiang [1 ]
Han, Dongwei [1 ]
机构
[1] Tongji Univ, Dept Prosthodont, Sch Stomatol, Shanghai 200072, Peoples R China
来源
QUINTESSENCE INTERNATIONAL | 2009年 / 40卷 / 09期
关键词
all-ceramic CAD/CAM crowns; finish line curvature; fit; metal-ceramic crowns; CASTING RING LINERS; IN-CERAM; RESTORATIONS; PORCELAIN; DISTORTION; SYSTEMS;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To investigate the effect of abutment finish line curvature on the fit of all-ceramic CAD/CAM crowns and metal-ceramic crowns. Method and Materials: Three types of finish line curvature abutments (1-, 3-, and 5-mm curvature) were prepared on typodont maxillary central incisors. For each type of abutment, 5 all-ceramic crowns (Cercon system, DeguDent) and 5 metal-ceramic crowns were fabricated. The marginal gaps of copings and veneered crowns were measured on a profile projector. The data were calculated and analyzed with 2-way ANOVA and Tukey HSD test (alpha = .05). Results: The mean labial, lingual, mesial, and distal marginal gaps (SD) of all-ceramic crowns were similar: respectively, 54 (10), 51 (11), 47 (13), and 49 (9) mu m for 1-mm curvature; 49 (12), 53 (11), 54 (10), and 55 (12) mu m for 3-mm curvature; and 57 (12), 54 (11), 53 (10), and 52 (9) mu m for 5-mm curvature. The mean labial, lingual, mesial, and distal marginal gaps (SD) of metal-ceramic crowns were 36 (7), 41 (9), 26 (8), and 28 (10) mu m, respectively, for 1-mm curvature. The mean labial and lingual marginal gaps (SD) of metal-ceramic crowns for 3-mm curvature were 45 (8) and 48 (9) mu m, respectively-significantly larger than mesial (P = .01 and .007) and distal (P = .03 and .02) gaps. The mean labial and lingual marginal gaps (SD) of metal-ceramic crowns for 5-mm curvature were 76 (10) and 74 (15) mu m, respectively-significantly larger than mesial (P = .001 and .001) and distal (P = .001 and .001) gaps. Conclusions: The abutment finish line curvature had no significant effect on the marginal fit of all-ceramic crowns, but had a significant effect on the marginal fit of metal-ceramic crowns. (Quintessence Int 2009; 40: 745-752)
引用
收藏
页码:745 / 752
页数:8
相关论文
共 50 条
  • [41] Predictable aesthetics with metal-ceramic and all-ceramic crowns: the critical importance of soft-tissue management
    Donovan, TE
    Cho, GC
    PERIODONTOLOGY 2000, 2001, 27 : 121 - 130
  • [42] Clinical marginal and internal gaps of zirconia all-ceramic crowns
    Kokubo, Yuji
    Tsumita, Mitsuyoshi
    Kano, Takamitsu
    Sakurai, Satoe
    Fukushima, Shunji
    JOURNAL OF PROSTHODONTIC RESEARCH, 2011, 55 (01) : 40 - 43
  • [43] Long-term performance of implant-supported metal-ceramic and all-ceramic single crowns
    Rammelsberg, Peter
    Bermejo, Justo Lorenzo
    Kappel, Stefanie
    Meyer, Andre
    Zenthoefer, Andreas
    JOURNAL OF PROSTHODONTIC RESEARCH, 2020, 64 (03) : 332 - 339
  • [44] Marginal and internal fit of metal-ceramic crowns fabricated with a new laser melting technology
    Quante, Katrin
    Ludwig, Klaus
    Kern, Matthias
    DENTAL MATERIALS, 2008, 24 (10) : 1311 - 1315
  • [45] Marginal and internal fit of metal-ceramic crowns fabricated with a new laser melting technology
    Private Dental Office, Cologne, Germany
    不详
    Dent. Mater., 10 (1311-1315):
  • [46] Influence of porcelain veneering on the marginal fit of Digident and Lava CAD/CAM zirconia ceramic crowns
    Pak, Hyun-Soon
    Han, Jung-Suk
    Lee, Jai-Bong
    Kim, Sung-Hun
    Yang, Jae-Ho
    JOURNAL OF ADVANCED PROSTHODONTICS, 2010, 2 (02): : 33 - 38
  • [47] The effect of ferrule on the fracture mode of endodontically treated canines restored with fibre posts and metal-ceramic or all-ceramic crowns
    Fragou, Theodora
    Tortopidis, Dimitrios
    Kontonasaki, Eleana
    Evangelinaki, Evangelia
    Ioannidis, Konstantinos
    Petridis, Haralampos
    Koidis, Petros
    JOURNAL OF DENTISTRY, 2012, 40 (04) : 276 - 285
  • [48] Comparison of the Marginal Fit of Cobalt-Chromium Metal-Ceramic Crowns Fabricated by CAD/CAM Techniques and Conventional Methods at Three Production Stages
    Real-Voltas, Francisco
    Romano-Cardozo, Elisabeth
    Figueras-Alvarez, Oscar
    Brufau-de Barbaera, Magi
    Cabratosa-Termes, Josep
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2017, 30 (03) : 304 - 305
  • [49] Comparison of the marginal fit of different all-ceramic and metal-ceramic crown systems: an in vitro study
    Polansky, R.
    Heschl, A.
    Arnetzl, G.
    Haas, M.
    Wegscheider, W.
    INTERNATIONAL JOURNAL OF STOMATOLOGY & OCCLUSION MEDICINE, 2010, 3 (02) : 106 - 110
  • [50] Probability of fracture of all-ceramic crowns
    Chai, J
    Takahashi, Y
    Sulaiman, F
    Chong, KH
    Lautenschlager, EP
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2000, 13 (05) : 420 - 424