Model-free estimation of available power using deep learning

被引:10
作者
Gocmen, Tuhfe [1 ]
Urban, Albert Meseguer [1 ]
Liew, Jaime [1 ]
Lio, Alan Wai Hou [1 ]
机构
[1] Tech Univ Denmark, Dept Wind Energy, DTU, Frederiksborgvej 399, DK-4000 Roskilde, Denmark
关键词
WIND-SPEED ESTIMATOR; UNCERTAINTY; PREDICTION; GENERATION; TURBINES; SUPPORT; PLANTS; LOAD;
D O I
10.5194/wes-6-111-2021
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In order to assess the level of power reserves during down-regulation, the available power of a wind turbine needs to be estimated. The current practice in available power estimation is heavily dependent on the pre-defined performance parameters of the turbine and the curtailment strategy followed. This paper proposes a single-input model-free approach dynamic estimation of the available power using recurrent neural networks. Accordingly, it combines wind turbine control considerations and modern forecasting methodologies for a model-free, single-input estimation of available power. It enables a robust real-time implementation of dynamic delta control, as well as higher-accuracy provision of the reserves to the system operators. The model-free approach requires only 1 Hz wind speed measurements as input and estimates 1 Hz available power as output. The neural network is trained, tested and validated using the DTU 10 MW reference wind turbine HAWC2 model under realistic atmospheric conditions. The unsteady patterns in the turbulent flow are represented via long short-term memory (LSTM) neurons which are trained during a period of normal operation. The adaptability of the network to changing inflow conditions is ensured via transfer learning, where the last LSTM layer is updated using new measurements. It is seen that the sensitivity of the networks to changing wind speed is much higher than that of turbulence, and the updates are to be implemented solely based on the altering inflow velocity. The validation of the trained LSTM networks on time series with 7, 9 and 11 m s(-1) mean wind speeds demonstrates high accuracy (less than 1 % bias) and capability of transfer-learning online. Including highly turbulent inflow cases, the networks have shown to comply with the most recent grid codes, which require the quality of the available power estimations to be evaluated with high accuracy (less than 3.3 % standard deviation of the error around zero bias) at 1 min intervals.
引用
收藏
页码:111 / 129
页数:19
相关论文
共 57 条
[1]  
Abadi M, 2016, PROCEEDINGS OF OSDI'16: 12TH USENIX SYMPOSIUM ON OPERATING SYSTEMS DESIGN AND IMPLEMENTATION, P265
[2]   Sparse-Sensor Placement for Wind Farm Control [J].
Annoni, J. ;
Taylor, T. ;
Bay, C. ;
Johnson, K. ;
Pao, L. ;
Fleming, P. ;
Dykes, K. .
SCIENCE OF MAKING TORQUE FROM WIND (TORQUE 2018), 2018, 1037
[3]  
[Anonymous], 2017, ARXIV170708110
[4]  
[Anonymous], 2006, THESIS
[5]   A review on frequency support provision by wind power plants: Current and future challenges [J].
Attya, A. B. ;
Dominguez-Garcia, J. L. ;
Anaya-Lara, O. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2018, 81 :2071-2087
[6]  
Bak C., 2012, EUR WIND EN C EXH 20
[7]  
Bak Christian., 2013, DESCRIPTION DTU 10 M, DOI DOI 10.1017/CBO9781107415324.004
[8]  
Bali V, 2019, INT C CONFL CLOUD CO, DOI [10.1109/ CONFLUENCE.2019.8776923, DOI 10.1109/CONFLUENCE.2019.8776923]
[9]   Variability of the Wind Turbine Power Curve [J].
Bandi, Mahesh M. ;
Apt, Jay .
APPLIED SCIENCES-BASEL, 2016, 6 (09)
[10]  
Bhowmik S, 1998, IEEE IND APPLIC SOC, P2387, DOI 10.1109/IAS.1998.730149