共 50 条
Distinct predictive values of current neuroprognostic guidelines in post-cardiac arrest patients
被引:50
|作者:
Zhou, Sonya E.
[1
]
Maciel, Carolina B.
[1
,2
]
Ormseth, Cora H.
[1
]
Beekman, Rachel
[1
]
Gilmore, Emily J.
[1
]
Greer, David M.
[1
,3
]
机构:
[1] Yale Univ, Sch Med, Dept Neurol, New Haven, CT 06510 USA
[2] Univ Florida, Coll Med, Dept Neurol, UF Hlth Shands Hosp, Gainesville, FL 32611 USA
[3] Boston Univ, Sch Med, Dept Neurol, Boston, MA 02118 USA
来源:
基金:
美国国家卫生研究院;
关键词:
Cardiac arrest;
Neuroprognostication;
Self-fulfilling prophecy;
Hypoxic-ischaemic encephalopathy;
Post-cardiac arrest syndrome;
Outcomes assessment;
Heart arrest;
ADULT COMATOSE SURVIVORS;
CARDIOPULMONARY-RESUSCITATION;
NEUROLOGICAL PROGNOSTICATION;
INTERRATER RELIABILITY;
HYPOTHERMIA;
CARE;
PUPILLOMETRY;
ASSOCIATION;
WITHDRAWAL;
OUTCOMES;
D O I:
10.1016/j.resuscitation.2019.03.035
中图分类号:
R4 [临床医学];
学科分类号:
1002 ;
100602 ;
摘要:
Purpose: To assess the performance of neuroprognostic guidelines proposed by the American Academy of Neurology (AAN), European Resuscitation Council/European Society of Intensive Care Medicine (ERC/ESICM), and American Heart Association (AHA) in predicting outcomes of patients who remain unconscious after cardiac arrest. Methods: We retrospectively identified a cohort of unconscious post-cardiac arrest patients at a single tertiary care centre from 2011 to 2017 and reviewed hospital records for clinical, radiographic, electrophysiologic, and biochemical findings. Outcomes at discharge and 6 months post-arrest were abstracted and dichotomized as good (Cerebral Performance Category (CPC) scores of 1-2) versus poor (CPC 3-5). Outcomes predicted by current guidelines were compared to actual outcomes, with false positive rate (FPR) used as a measure of predictive value. Results: Of 226 patients, 36% survived to discharge, including 24 with good outcomes; 52% had withdrawal of life-sustaining therapies (WLST) during hospitalization. The AAN guideline yielded discharge and 6-month FPR of 8% and 15%, respectively. In contrast, the ERC/ESICM had a FPR of 0% at both discharge and 6 months. The AHA predictors had variable specificities, with diffuse hypoxic-ischaemic injury on MRI performing especially poorly (FPR 12%) at both discharge and 6 months. Conclusions: Though each guideline had components that performed well, only the ERC/ESICM guideline yielded a 0% FPR. Amongst the AAN and AHA guidelines, false positives emerged more readily at 6 months, reflective of continuing recovery after discharge, even in a cohort inevitably biased by WLST. Further assessment of predictive modalities is needed to improve neuroprognostic accuracy.
引用
收藏
页码:343 / 350
页数:8
相关论文