Multidetector Computed Tomography Chest Examinations With Low-Kilovoltage Protocols in Adults: Effect on Image Quality and Radiation Dose

被引:44
|
作者
Kim, Mi Jung [1 ]
Park, Chul Hi [1 ]
Choi, Soo Jin [1 ]
Hwang, Kyung Hoon [2 ]
Kim, Hyung Sik [1 ]
机构
[1] Gachon Univ, Gil Med Ctr, Dept Radiol, Inchon 450760, South Korea
[2] Gachon Univ, Gil Med Ctr, Dept Nucl Med, Inchon 450760, South Korea
关键词
computed tomography (CT); multidetector row; thorax; low kilovoltage; image quality; radiation exposure; CT; THORAX;
D O I
10.1097/RCT.0b013e318181fab5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The purpose of our study was to assess the effect on image quality and radiation dose of chest multidetector computed tomography (CT) examinations with low-kilovoltage protocols for adults. Methods: This study was approved by the institutional review board of our medical center. Two hundred ten patients (83 women, 127 men; mean age, 56.1 years) requiring contrast-enhanced chest CT examination were randomly assigned to I of 3 protocol groups: (1) protocol A, the standard protocol, with 120 kilovolt (peak) (kV[p]) and 100 effective milliampere-second (eff mA s); (2) protocol B, with 100 kV(p) and 140 eff mA s; and (3) protocol C, with 80 kV(p) and 180 eff mA s. Each group included 70 patients. Contrast material injection protocols were standardized for all groups. Three radiologists blinded to the CT parameters used assessed images in random order for 20 items from 4 anatomical regions. They ranked the subjective image quality using a 4-point scale. The volume computed tomography dose index (CTDIvol) and dose length product (DLP) were displayed by the CT unit after the automatic exposure control-driven acquisition was recorded for each group; the differences were analyzed for statistical significance. Results: When the overall agreement was pooled from the 3 observers, the qualitative score analysis revealed no significant difference between the 100-kV(p) and the standard protocols (P > 0.05). However, when the scores were compared between the 80-kV(p) and the standard protocols, a marginal significance (P = 0.054) was observed. When the patients in the group with an 80-kV(p) protocol were subcategorized according to body mass index (BMI), the image quality scores of all BMI subgroups, of the 80-kV(p) protocol, were not significantly different from those of the standard protocol. However, an increase in the BMI tended to be associated with a decrease in the subjective image quality. The mean values of CTDIvol for 120-, 100-, and 80-kV(p) protocols were 5.042, 4.507, and 2.883, respectively. The mean values of DLP for each protocol were 187.5, 158.7, and 105.8, respectively. The CTDIvol and DLP of the low-kilovoltage protocols were significantly lower than those of the standard protocol (P < 0.01). The DLP of the 100- and 80-kV(p) protocols were reduced radiation exposure doses in 15.36% and 43.57%, respectively, as compared with the standard protocol. Conclusions: The use of low-kilovoltage protocol resulted in a significant reduction in the radiation exposure at chest CT, with image qualities comparable with those of the standard protocols.
引用
收藏
页码:416 / 421
页数:6
相关论文
共 50 条
  • [1] Low-kilovoltage multi-detector row chest CT in adults: Feasibility and effect on image quality and iodine dose
    Sigal-Cinqualbre, AB
    Hennequin, R
    Abada, HT
    Chen, X
    Paul, JF
    RADIOLOGY, 2004, 231 (01) : 169 - 174
  • [2] Radiation dose reduction from low-kilovoltage liver computed tomography using multidetector row computed tomography
    Cho, Pyong-Kon
    RADIATION PROTECTION DOSIMETRY, 2013, 154 (01) : 76 - 80
  • [3] Automated Low-Kilovoltage Selection in Pediatric Computed Tomography Angiography Phantom Study Evaluating Effects on Radiation Dose and Image Quality
    Siegel, Marilyn Joy
    Ramirez-Giraldo, Juan Carlos
    Hildebolt, Charles
    Bradley, David
    Schmidt, Bernhard
    INVESTIGATIVE RADIOLOGY, 2013, 48 (08) : 584 - 589
  • [4] Patient dose and image quality from the low kilovoltage dynamic liver computed tomography examinations
    Cho, Pyong-Kon
    Lee, Sung-Hyun
    Lee, Mi-Hwa
    Cho, Young-Kwon
    Chon, Kwon-Soo
    Kim, Yong-Min
    ASIAN BIOMEDICINE, 2013, 7 (01) : 119 - 124
  • [5] Low-Kilovoltage, High-Tube-Current MDCT of Liver in Thin Adults: Pilot Study Evaluating Radiation Dose, Image Quality, and Display Settings
    Nakaura, Takeshi
    Awai, Kazuo
    Oda, Seitaro
    Funama, Yoshinori
    Harada, Kazunori
    Uemura, Shouzaburou
    Yamashita, Yasuyuki
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (06) : 1332 - 1338
  • [6] High-Pitch Spiral Computed Tomography Effect on Image Quality and Radiation Dose in Pediatric Chest Computed Tomography
    Lell, Michael M.
    May, Matthias
    Deak, Paul
    Alibek, Sedat
    Kuefner, Michael
    Kuettner, Axel
    Koehler, Henrik
    Achenbach, Stephan
    Uder, Michael
    Radkow, Tanja
    INVESTIGATIVE RADIOLOGY, 2011, 46 (02) : 116 - 123
  • [7] Usefulness of Ag Additional Filter on Image Quality and Radiation Dose for Low-Dose Chest Computed Tomography
    Kawamoto, Keishin
    Sato, Hideyuki
    Kogure, Yosuke
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2024, 48 (02) : 236 - 243
  • [8] Comparison of the Radiation Dose from Cone Beam Computed Tomography and Multidetector Computed Tomography in Examinations of the Hand
    Neubauer, J.
    Neubauer, C.
    Gerstmair, A.
    Krauss, T.
    Reising, K.
    Zajonc, H.
    Kotter, E.
    Langer, M.
    Fiebich, M.
    Voigt, J.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2016, 188 (05): : 488 - 493
  • [9] A multi-institutional assessment of low-dose protocols in chest computed tomography: Dose and image quality
    Tonkopi, Elena
    Tetteh, Mercy Afadzi
    Gunn, Catherine
    Ashraf, Haseem
    Rusten, Sigrid Lia
    Safi, Perkhah
    Tinsoe, Nora Suu
    Colford, Kylie
    Ouellet, Olivia
    Naimi, Salma
    Johansen, Safora
    ACTA RADIOLOGICA OPEN, 2024, 13 (01)
  • [10] Regional survey of image quality and radiation dose in computed tomography examinations in Saudi Arabia
    M. K. Saeed
    A. S. Alzoubi
    J. M. Al-Qahtani
    Australasian Physical & Engineering Sciences in Medicine, 2014, 37 : 279 - 283