Modal analysis for implant stability assessment: Sensitivity of this methodology for different implant designs

被引:35
作者
Zanetti, Elisabetta Maria [1 ]
Ciaramella, Stefano [2 ]
Cali, Michele [3 ]
Pascoletti, Giulia [1 ]
Martorelli, Massimo [2 ]
Asero, Riccardo [4 ]
Watts, David C. [5 ,6 ]
机构
[1] Univ Perugia, Dept Engn, Via Duranti 67, I-06125 Perugia, Italy
[2] Univ Naples Federico II, Fraunhofer JL IDEAS, Dept Ind Engn, Ple Tecchio 80, I-80125 Naples, Italy
[3] Univ Catania, Elect Elect & Comp Engn Dept, Vle A Doria 6, I-95125 Catania, Italy
[4] Studio Odontoiatr Asero, Via Gen Cantore 23, I-95123 Catania, Italy
[5] Univ Manchester, Sch Med Sci, Manchester, Lancs, England
[6] Univ Manchester, Photon Sci Inst, Manchester, Lancs, England
关键词
Reverse engineering; CAD; Finite element analysis; Dental materials; Material properties; Implant stability; Bone properties; Endosteal implants; Osseointegration; RESONANCE FREQUENCY-ANALYSIS; CLASS-II RESTORATIONS; MECHANICAL-BEHAVIOR; RESIN-COMPOSITE; NUMERICAL APPROACH; LOADING PROTOCOLS; DENTAL IMPLANTS; CORTICAL BONE; OSSEOINTEGRATION; OVERDENTURES;
D O I
10.1016/j.dental.2018.05.016
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. To investigate the influence of implant design on the change in the natural frequency of bone-implant system during osseointegration by means of a modal 3D finite element analysis. Methods. Six implants were considered. Solid models were obtained by means of reverse engineering techniques. The mandibular bone geometry was built-up from a CT scan dataset through image segmentation. Each implant was virtually implanted in the mandibular bone. Two different models have been considered, differing in the free length of the mandibular branch (gong branch' and 'short branch') in order to simulate the variability of boundary conditions when performing vibro metric analyses. Modal analyses were carried out for each model, and the first three resonance frequencies were assessed with the respective vibration modes. Results. With reference to the 'long branch' model, the first three modes of vibration are whole bone vibration with minimum displacement of the implant relative to bone, with the exception of the initial condition (1% bone maturation) where the implant is not osseointegrated. By contrast, implant displacements become relevant in the 'short branch' model, unless osseointegration level is beyond 20%. The difference between resonance frequency at whole bone maturation and resonance frequency at 1% bone maturation remained lower than 6.5% for all modes, with the exception of the third mode of vibration in the 'D' implant where this difference reached 9.7%. With reference to the 'short branch', considering the first mode of vibration, 61-68% of the frequency increase was achieved at 10% osseointegration; 72-79% was achieved at 20%; 89-93% was achieved at 50% osseointegration. The pattern of the natural frequency versus the osseointegration level is similar among different modes of vibration. Significance. Resonance frequencies and their trends towards osseointegration level may differ between implant designs, and in different boundary conditions that are related to implant position inside the mandible; tapered implants are the most sensitive to bone maturation levels, small implants have very little sensitivity. Resonance frequencies are less sensitive to bone maturation level beyond 50%. (C) 2018 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:1235 / 1245
页数:11
相关论文
共 50 条
  • [31] Implant stability and bone density: assessment of correlation in fresh cadavers using conventional and osteotome implant sockets
    Cehreli, Murat Cavit
    Kokat, Ali Murat
    Comert, Ayhan
    Akkocaoglu, Murat
    Tekdemir, Ibrahim
    Akca, Kwanc
    CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (10) : 1163 - 1169
  • [32] Finite Element Analysis of the Stress Distribution Associated With Different Implant Designs for Different Bone Densities
    Kurtulus, Ikbal Leblebicioglu
    Kilic, Kerem
    Bal, Burak
    Kilavuz, Ahmet
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (07): : 614 - 622
  • [33] A biomechanical assessment of the relation between the oral implant stability at insertion and subjective bone quality assessment
    Alsaadi, Ghada
    Quirynen, Marc
    Michiels, Katleen
    Jacobs, Reinhilde
    van Steenberghe, Daniel
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2007, 34 (04) : 359 - 366
  • [34] Comparison of the Primary Stability of Two Implant Designs in Two Different Bone Types: An In Vitro Study
    Bilhan, Hakan
    Bilmenoglu, Caglar
    Urgun, Aliye Ceren
    Ates, Gokcen
    Bural, Canan
    Cilingir, Altug
    Geckili, Onur
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2015, 30 (05) : 1036 - 1040
  • [35] Analysis of implant stability changes in immediate loading using a laser displacement sensor in vivo and comparison of its sensitivity with that of resonance frequency analysis
    Murakami, Kazuhiro
    Yamamoto, Kazuhiko
    Ishida, Junichi
    Tsutsumi, Sadami
    Kirita, Tadaaki
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (11) : 1341 - 1356
  • [36] Measurement of dental implant stability by resonance frequency analysis: A review of the literature
    Pilar Quesada-Garcia, Ma
    Prados-Sanchez, Estrella
    Victoria Olmedo-Gaya, Ma
    Munoz-Soto, Esther
    Paloma Gonzalez-Rodriguez, Ma
    Vallecillo-Capilla, Manuel
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2009, 14 (10): : E538 - E546
  • [37] Assessment of Implant Stability Following Sinus Lift Procedures with Different Grafting Materials
    Jelusic, Damir
    Puhar, Ivan
    Plancak, Darije
    ACTA STOMATOLOGICA CROATICA, 2014, 48 (01) : 25 - 32
  • [38] Experimental Investigation of Vibration Analysis on Implant Stability for a Novel Implant Design
    Lu, Shouxun
    Vien, Benjamin Steven
    Russ, Matthias
    Fitzgerald, Mark
    Chiu, Wing Kong
    SENSORS, 2022, 22 (04)
  • [39] BIOMECHANICAL ANALYSIS OF FULL-ARCH IMPLANT-SUPPORTED REHABILITATIONS WITH DIFFERENT DESIGNS
    Barahona, Maria Ines
    Campos, Jose Reis
    Ramos, Nuno Viriato
    Vaz, Mario
    Figueiral, Maria Helena
    Correia, Andre
    M2D2015: PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON MECHANICS AND MATERIALS IN DESIGN, 2015, : 1475 - 1480
  • [40] Assessment of Implant Stability in Immediate Implant Placement using Different Bone Grafting materials: A Clinical Study
    Jalaluddin, Mohammad
    Sathe, Saurabh
    Thomas, Joyce
    Haleem, Shaista
    Naik, Sachin
    Shivanna, Madhuniranjanswamy Mahalakshmamma
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2021, 13 (05): : 612 - 615