Modal analysis for implant stability assessment: Sensitivity of this methodology for different implant designs

被引:35
|
作者
Zanetti, Elisabetta Maria [1 ]
Ciaramella, Stefano [2 ]
Cali, Michele [3 ]
Pascoletti, Giulia [1 ]
Martorelli, Massimo [2 ]
Asero, Riccardo [4 ]
Watts, David C. [5 ,6 ]
机构
[1] Univ Perugia, Dept Engn, Via Duranti 67, I-06125 Perugia, Italy
[2] Univ Naples Federico II, Fraunhofer JL IDEAS, Dept Ind Engn, Ple Tecchio 80, I-80125 Naples, Italy
[3] Univ Catania, Elect Elect & Comp Engn Dept, Vle A Doria 6, I-95125 Catania, Italy
[4] Studio Odontoiatr Asero, Via Gen Cantore 23, I-95123 Catania, Italy
[5] Univ Manchester, Sch Med Sci, Manchester, Lancs, England
[6] Univ Manchester, Photon Sci Inst, Manchester, Lancs, England
关键词
Reverse engineering; CAD; Finite element analysis; Dental materials; Material properties; Implant stability; Bone properties; Endosteal implants; Osseointegration; RESONANCE FREQUENCY-ANALYSIS; CLASS-II RESTORATIONS; MECHANICAL-BEHAVIOR; RESIN-COMPOSITE; NUMERICAL APPROACH; LOADING PROTOCOLS; DENTAL IMPLANTS; CORTICAL BONE; OSSEOINTEGRATION; OVERDENTURES;
D O I
10.1016/j.dental.2018.05.016
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. To investigate the influence of implant design on the change in the natural frequency of bone-implant system during osseointegration by means of a modal 3D finite element analysis. Methods. Six implants were considered. Solid models were obtained by means of reverse engineering techniques. The mandibular bone geometry was built-up from a CT scan dataset through image segmentation. Each implant was virtually implanted in the mandibular bone. Two different models have been considered, differing in the free length of the mandibular branch (gong branch' and 'short branch') in order to simulate the variability of boundary conditions when performing vibro metric analyses. Modal analyses were carried out for each model, and the first three resonance frequencies were assessed with the respective vibration modes. Results. With reference to the 'long branch' model, the first three modes of vibration are whole bone vibration with minimum displacement of the implant relative to bone, with the exception of the initial condition (1% bone maturation) where the implant is not osseointegrated. By contrast, implant displacements become relevant in the 'short branch' model, unless osseointegration level is beyond 20%. The difference between resonance frequency at whole bone maturation and resonance frequency at 1% bone maturation remained lower than 6.5% for all modes, with the exception of the third mode of vibration in the 'D' implant where this difference reached 9.7%. With reference to the 'short branch', considering the first mode of vibration, 61-68% of the frequency increase was achieved at 10% osseointegration; 72-79% was achieved at 20%; 89-93% was achieved at 50% osseointegration. The pattern of the natural frequency versus the osseointegration level is similar among different modes of vibration. Significance. Resonance frequencies and their trends towards osseointegration level may differ between implant designs, and in different boundary conditions that are related to implant position inside the mandible; tapered implants are the most sensitive to bone maturation levels, small implants have very little sensitivity. Resonance frequencies are less sensitive to bone maturation level beyond 50%. (C) 2018 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:1235 / 1245
页数:11
相关论文
共 50 条
  • [21] Influence of different implant placement techniques to improve primary implant stability in low-density bone: A systematic review
    Palaskar, Jayant N.
    Joshi, Nikhil
    Shah, Pooja M.
    Gullapalli, Poorva
    Vinay, Vineel
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2020, 20 (01) : 11 - 16
  • [22] Bone's responses to different designs of implant-supported fixed partial dentures
    Rungsiyakull, Chaiy
    Chen, Junning
    Rungsiyakull, Pimduen
    Li, Wei
    Swain, Michael
    Li, Qing
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2015, 14 (02) : 403 - 411
  • [23] Assessment of Implant Stability of Patients With and Without Radiotherapy Using Resonance Frequency Analysis
    Karayazgan-Saracoglu, Banu
    Atay, Arzu
    Zulfikar, Haluk
    Erpardo, Yuksel
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (01) : 30 - 35
  • [24] Influence of Implant Dimensions and Position on Implant Stability: A Prospective Clinical Study in Maxilla Using Resonance Frequency Analysis
    Nappo, Antonio
    Rengo, Carlo
    Pantaleo, Giuseppe
    Spagnuolo, Gianrico
    Ferrari, Marco
    APPLIED SCIENCES-BASEL, 2019, 9 (05):
  • [25] Evaluation of Biomechanical and Stress Distribution of Different Dental Implant Designs: Primary Stability and Photoelastic Analysis
    Tardelli, J. D. C.
    Macedo, A. P.
    Valente, da Costa
    IRBM, 2022, 43 (02) : 100 - 106
  • [26] Sensitivity of Resonance Frequency Analysis for Detecting Early Implant Failure: A Case-Control Study
    Monje, Alberto
    Ortega-Oller, Inmaculada
    Galindo-Moreno, Pablo
    Catena, Andres
    Monje, Florencio
    O'Valle, Francisco
    Suarez, Fernando
    Wang, Hom-Lay
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (02) : 456 - 461
  • [27] Effect of Locally Applied bFGF on Implant Stability: Biomechanical Evaluation of 2 Different Implant Surfaces in Rabbits
    Kartal, Yasemin
    Ucok, Cahit
    Ozgul, Ozkan
    Kocyigit, Ismail Doruk
    Suer, Berkay Tolga
    IMPLANT DENTISTRY, 2014, 23 (04) : 463 - 470
  • [28] Clinical Assessment of Dental Implant Stability During Follow-Up: What Is Actually Measured, and Perspectives
    Zanetti, Elisabetta M.
    Pascoletti, Giulia
    Cali, Michele
    Bignardi, Cristina
    Franceschini, Giordano
    BIOSENSORS-BASEL, 2018, 8 (03):
  • [29] Effect of Implant Thread Geometry on Secondary Stability, Bone Density, and Bone-to-Implant Contact : A Biomechanical and Histological Analysis
    Trisi, Paolo
    Berardini, Marco
    Falco, Antonello
    Vulpiani, Michele Podaliri
    IMPLANT DENTISTRY, 2015, 24 (04) : 384 - 391
  • [30] Resonance Frequency Analysis to Evaluate the Effect of Different Drilling Techniques on Implant Stability at Different Time Intervals: A Randomized Clinical Trial
    Sunny, Greeshma
    Mishra, Sunil K.
    Chowdhary, Ramesh
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (05) : 1055 - +