Modal analysis for implant stability assessment: Sensitivity of this methodology for different implant designs

被引:35
|
作者
Zanetti, Elisabetta Maria [1 ]
Ciaramella, Stefano [2 ]
Cali, Michele [3 ]
Pascoletti, Giulia [1 ]
Martorelli, Massimo [2 ]
Asero, Riccardo [4 ]
Watts, David C. [5 ,6 ]
机构
[1] Univ Perugia, Dept Engn, Via Duranti 67, I-06125 Perugia, Italy
[2] Univ Naples Federico II, Fraunhofer JL IDEAS, Dept Ind Engn, Ple Tecchio 80, I-80125 Naples, Italy
[3] Univ Catania, Elect Elect & Comp Engn Dept, Vle A Doria 6, I-95125 Catania, Italy
[4] Studio Odontoiatr Asero, Via Gen Cantore 23, I-95123 Catania, Italy
[5] Univ Manchester, Sch Med Sci, Manchester, Lancs, England
[6] Univ Manchester, Photon Sci Inst, Manchester, Lancs, England
关键词
Reverse engineering; CAD; Finite element analysis; Dental materials; Material properties; Implant stability; Bone properties; Endosteal implants; Osseointegration; RESONANCE FREQUENCY-ANALYSIS; CLASS-II RESTORATIONS; MECHANICAL-BEHAVIOR; RESIN-COMPOSITE; NUMERICAL APPROACH; LOADING PROTOCOLS; DENTAL IMPLANTS; CORTICAL BONE; OSSEOINTEGRATION; OVERDENTURES;
D O I
10.1016/j.dental.2018.05.016
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. To investigate the influence of implant design on the change in the natural frequency of bone-implant system during osseointegration by means of a modal 3D finite element analysis. Methods. Six implants were considered. Solid models were obtained by means of reverse engineering techniques. The mandibular bone geometry was built-up from a CT scan dataset through image segmentation. Each implant was virtually implanted in the mandibular bone. Two different models have been considered, differing in the free length of the mandibular branch (gong branch' and 'short branch') in order to simulate the variability of boundary conditions when performing vibro metric analyses. Modal analyses were carried out for each model, and the first three resonance frequencies were assessed with the respective vibration modes. Results. With reference to the 'long branch' model, the first three modes of vibration are whole bone vibration with minimum displacement of the implant relative to bone, with the exception of the initial condition (1% bone maturation) where the implant is not osseointegrated. By contrast, implant displacements become relevant in the 'short branch' model, unless osseointegration level is beyond 20%. The difference between resonance frequency at whole bone maturation and resonance frequency at 1% bone maturation remained lower than 6.5% for all modes, with the exception of the third mode of vibration in the 'D' implant where this difference reached 9.7%. With reference to the 'short branch', considering the first mode of vibration, 61-68% of the frequency increase was achieved at 10% osseointegration; 72-79% was achieved at 20%; 89-93% was achieved at 50% osseointegration. The pattern of the natural frequency versus the osseointegration level is similar among different modes of vibration. Significance. Resonance frequencies and their trends towards osseointegration level may differ between implant designs, and in different boundary conditions that are related to implant position inside the mandible; tapered implants are the most sensitive to bone maturation levels, small implants have very little sensitivity. Resonance frequencies are less sensitive to bone maturation level beyond 50%. (C) 2018 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:1235 / 1245
页数:11
相关论文
共 50 条
  • [1] Primary implant stability of two implant macro-designs in different alveolar ridge morphologies: an in vitro study
    Jenner, Anna
    Sabatini, Gabriela P.
    Abou-Ayash, Samir
    Couso-Queiruga, Emilio
    Chappuis, Vivianne
    Raabe, Clemens
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2025, 11 (01)
  • [2] Primary Implant Stability Analysis of Different Dental Implant Connections and Designs-An In Vitro Comparative Study
    Raz, Perry
    Meir, Haya
    Levartovsky, Shifra
    Sebaoun, Alon
    Beitlitum, Ilan
    MATERIALS, 2022, 15 (09)
  • [3] Torsional resonance frequency analysis: a novel method for assessment of dental implant stability
    Tang, Yu-Long
    Li, Bing
    Jin, Wei
    Li, De-Hua
    CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (06) : 615 - 622
  • [4] Assessment of implant stability by resonant frequency analysis
    Konstantinovic, Vitomir S.
    Ivanjac, Filip
    Lazic, Vojkan
    Djordjevic, Igor
    VOJNOSANITETSKI PREGLED, 2015, 72 (02) : 169 - 174
  • [5] Influence of Implant Macro-Design, -Length, and -Diameter on Primary Implant Stability Depending on Different Bone Qualities Using Standard Drilling Protocols-An In Vitro Analysis
    Stoilov, Milan
    Shafaghi, Ramin
    Stark, Helmut
    Marder, Michael
    Kraus, Dominik
    Enkling, Norbert
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2023, 14 (09)
  • [6] Assessment of dental implant stability using resonance frequency analysis and quantitative ultrasound methods
    Heriveaux, Yoann
    Vayron, Romain
    Fraulob, Manon
    Lomami, Hugues Albini
    Lenormand, Camille
    Haiat, Guillaume
    JOURNAL OF PROSTHODONTIC RESEARCH, 2021, 65 (03) : 421 - 427
  • [7] Comparison of histomorphometry and microradiography of different implant designs to assess primary implant stability
    Romanos, Georgios
    Damouras, Michael
    Veis, Alexander A.
    Hess, Pablo
    Schwarz, Frank
    Brandt, Silvia
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2020, 22 (03) : 373 - 379
  • [8] In Vitro Assessment of Primary Stability of Straumann® Implant Designs
    Romanos, Georgios E.
    Ciornei, Gabriela
    Jucan, Adina
    Malmstrom, Hans
    Gupta, Bhumija
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2014, 16 (01) : 89 - 95
  • [9] Relationship between cortical bone thickness and implant stability at the time of surgery and secondary stability after osseointegration measured using resonance frequency analysis
    Tanaka, Kenko
    Sailer, Irena
    Iwama, Ryosuke
    Yamauchi, Kensuke
    Nogami, Shinnosuke
    Yoda, Nobuhiro
    Takahashi, Tetsu
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2018, 48 (06) : 360 - 372
  • [10] Fractal Dimension as a Tool for Assessment of Dental Implant Stability-A Scoping Review
    Mishra, Sukanya
    Kumar, Manoj
    Mishra, Lora
    Mohanty, Rinkee
    Nayak, Rashmita
    Das, Abhaya Chandra
    Mishra, Sambhab
    Panda, Saurav
    Lapinska, Barbara
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (14)