Accuracy of Mobile Device-Compatible 3D Scanners for Facial Digitization: Systematic Review and Meta-Analysis

被引:34
作者
Mai, Hang-Nga [1 ]
Lee, Du-Hyeong [1 ,2 ]
机构
[1] Kyungpook Natl Univ, Inst Translat Res Dent, Daegu, South Korea
[2] Kyungpook Natl Univ, Sch Dent, Dept Prosthodont, 2175 Dalgubeoldae Ro, Daegu 41940, South Korea
基金
新加坡国家研究基金会;
关键词
accuracy; facial digitization; facial scanners; systematic review; meta-analysis; FACE; REPRODUCIBILITY; VALIDATION; PHOTOGRAMMETRY; RELIABILITY; PROSTHESIS; TOOL;
D O I
10.2196/22228
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: The accurate assessment and acquisition of facial anatomical information significantly contributes to enhancing the reliability of treatments in dental and medical fields, and has applications in fields such as craniomaxillofacial surgery, orthodontics, prosthodontics, orthopedics, and forensic medicine. Mobile device-compatible 3D facial scanners have been reported to be an effective tool for clinical use, but the accuracy of digital facial impressions obtained with the scanners has not been explored. Objective: We aimed to review comparisons of the accuracy of mobile device-compatible face scanners for facial digitization with that of systems for professional 3D facial scanning. Methods: Individual search strategies were employed in PubMed (MEDLINE), Scopus, Science Direct, and Cochrane Library databases to search for articles published up to May 27, 2020. Peer-reviewed journal articles evaluating the accuracy of 3D facial models generated by mobile device-compatible face scanners were included. Cohen d effect size estimates and confidence intervals of standardized mean difference (SMD) data sets were used for meta-analysis. Results: By automatic database searching, 3942 articles were identified, of which 11 articles were considered eligible for narrative review, with 6 studies included in the meta-analysis. Overall, the accuracy of face models obtained using mobile device-compatible face scanners was significantly lower than that of face models obtained using professional 3D facial scanners (SMD 3.96 mm, 95% CI 2.81-5.10 mm; z=6.78; P<.001). The difference between face scanning when performed on inanimate facial models was significantly higher (SMD 10.53 mm, 95% CI 6.29-14.77 mm) than that when performed on living participants (SMD 2.58 mm, 95% CI 1.70-3.47 mm, P<.001, df=12.94). Conclusions: Overall, mobile device-compatible face scanners did not perform as well as professional scanning systems in 3D facial acquisition, but the deviations were within the clinically acceptable range of <1.5 mm. Significant differences between results when 3D facial scans were performed on inanimate facial objects and when performed on the faces of living participants were found; thus, caution should be exercised when interpreting results from studies conducted on inanimate objects.
引用
收藏
页数:13
相关论文
共 58 条
  • [1] Abdul-Wahab A, 2017, CLIN ENDOCRINOL, V86, P17
  • [2] Three-axis measurements with a novel system for 3D plantar foot scanning: iPhone X
    Alfaro-Santafe, Javier
    Gomez-Bernal, Antonio
    Lanuza-Cerzocimo, Carla
    Victor Alfaro-Santafe, Jose
    Perez-Morcillo, Aitor
    Jesus Almenar-Arasanz, Alejandro
    [J]. FOOTWEAR SCIENCE, 2020, 12 (02) : 123 - 131
  • [3] Alsiyabi Abdullah S, 2006, J Prosthodont, V15, P195, DOI 10.1111/j.1532-849X.2006.00100.x
  • [4] The Accuracy of Digital Face Scans Obtained from 3D Scanners: An In Vitro Study
    Amornvit, Pokpong
    Sanohkan, Sasiwimol
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2019, 16 (24)
  • [5] Feasibility and Accuracy of Noncontact Three-Dimensional Digitizers for Geometric Facial Defects: An In Vitro Comparison
    Aswehlee, Amel M.
    Elbashti, Mahmoud E.
    Hattori, Mariko
    Sumita, Yuka I.
    Taniguchi, Hisashi
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2018, 31 (06) : 601 - 606
  • [6] EVALUATION OF THE LASER SCANNER AS A SURFACE MEASURING TOOL AND ITS ACCURACY COMPARED WITH DIRECT FACIAL ANTHROPOMETRIC MEASUREMENTS
    AUNG, SC
    NGIM, RCK
    LEE, ST
    [J]. BRITISH JOURNAL OF PLASTIC SURGERY, 1995, 48 (08): : 551 - 558
  • [7] Comparison of low cost 3D structured light scanners for face modeling
    Bakirman, Tolga
    Gumusay, Mustafa Umit
    Reis, Hatice Catal
    Selbesoglu, Mahmut Oguz
    Yosmaoglu, Serra
    Yaras, Mehmet Cem
    Seker, Dursun Zafer
    Bayram, Bulent
    [J]. APPLIED OPTICS, 2017, 56 (04) : 985 - 992
  • [8] Three-Dimensional Esthetic Analysis in Treatment Planning for Implant-Supported Fixed Prosthesis in the Edentulous Maxilla: Review of the Esthetics Literature
    Bidra, Avinash S.
    [J]. JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2011, 23 (04) : 219 - 236
  • [9] Accuracy of digital technologies for the scanning of facial, skeletal, and intraoral tissues: A systematic review
    Bohner, Lauren
    Gamba, Diego Diaz
    Hanisch, Marcel
    Marcio, Bruno Silva
    Tortamano Neto, Pedro
    Lagana, Dalva Cruz
    Sesma, Newton
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (02) : 246 - 251
  • [10] STEREOPHOTOGRAMMETRY OF FACE - A PRELIMINARY INVESTIGATION INTO ACCURACY OF A SIMPLIFIED SYSTEM EVOLVED FOR CONTOUR MAPPING BY PHOTOGRAPHY
    BURKE, PH
    BEARD, LFH
    [J]. AMERICAN JOURNAL OF ORTHODONTICS, 1967, 53 (10): : 769 - &