Enhancing Adherence to Positive Airway Pressure Therapy for Sleep Disordered Breathing

被引:23
作者
Russell, Tonya [1 ]
机构
[1] Washington Univ, Sch Med, Div Pulm & Crit Care Med, St Louis, MO 63110 USA
关键词
positive airway pressure therapy; adherence; compliance; obstructive sleep apnea; sleep disordered breathing; QUALITY-OF-LIFE; RANDOMIZED CONTROLLED-TRIAL; CORONARY-ARTERY-DISEASE; RESTLESS LEGS SYNDROME; LONG-TERM COMPLIANCE; APNEA SYNDROME; CPAP TITRATION; NASAL CPAP; FOLLOW-UP; APNEA/HYPOPNEA SYNDROME;
D O I
10.1055/s-0034-1390070
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Sleep disordered breathing is made up of a group of conditions that include obstructive sleep apnea, central sleep apnea, complex sleep apnea, and sleep-related hypoventilation. Continuous positive airway pressure (CPAP) is the first-line therapy for obstructive sleep apnea. The other forms of sleep disordered breathing require different types of positive airway pressure (PAP). Adherence to PAP can be challenging and affected by multiple factors. Educating the patient regarding the consequences of untreated sleep disordered breathing and the benefits of PAP is the first step in improving adherence. Attention to social, psychological, and demographic factors that may contribute to difficulty complying is important. Addressing side effects such as nasal symptoms and equipment usability issues is also beneficial. Compliance can be monitored by the data download cards present in PAP machines, but clinicians must be aware of the limitations of the data obtained. The challenges of improving adherence occur along with the increasing need to demonstrate to payers a patient's adherence to and benefit from PAP therapy.
引用
收藏
页码:604 / 612
页数:9
相关论文
共 97 条
[1]   Utilization of healthcare resources in obstructive sleep apnea syndrome: a 5-year follow-up study in men using CPAP [J].
Albarrak, M ;
Banno, K ;
Sabbagh, AA ;
Delaive, K ;
Walld, R ;
Manfreda, J ;
Kryger, MH .
SLEEP, 2005, 28 (10) :1306-1311
[2]  
Aloia MS, 2005, J CLIN SLEEP MED, V1, P346
[3]   Treatment adherence and outcomes in flexible vs standard continuous positive airway pressure therapy [J].
Aloia, MS ;
Stanchina, M ;
Arnedt, JT ;
Malhotra, A ;
Millman, RP .
CHEST, 2005, 127 (06) :2085-2093
[4]   Auto-titrating versus standard continuous positive airway pressure for the treatment of obstructive sleep apnea: Results of a meta-analysis [J].
Ayas, NT ;
Patel, SR ;
Malhotra, A ;
Schulzer, M ;
Malhotra, M ;
Jung, D ;
Fleetham, J ;
White, DP .
SLEEP, 2004, 27 (02) :249-253
[5]   Randomized Controlled Trial Comparing Flexible and Continuous Positive Airway Pressure Delivery: Effects on Compliance, Objective and Subjective Sleepiness and Vigilance [J].
Bakker, Jessie ;
Campbell, Angela ;
Neill, Alister .
SLEEP, 2010, 33 (04) :523-529
[6]   Nasal versus oronasal continuous positive airway pressure masks for obstructive sleep apnea: a pilot investigation of pressure requirement, residual disease, and leak [J].
Bakker, Jessie P. ;
Neill, Alister M. ;
Campbell, Angela J. .
SLEEP AND BREATHING, 2012, 16 (03) :709-716
[7]   A Brief Survey of Patients' First Impression after CPAP Titration Predicts Future CPAP Adherence: A Pilot Study [J].
Balachandran, Jay S. ;
Yu, Xiaohong ;
Wroblewski, Kristen ;
Mokhlesi, Babak .
JOURNAL OF CLINICAL SLEEP MEDICINE, 2013, 9 (03) :199-205
[8]  
Ballard RD, 2007, J CLIN SLEEP MED, V3, P706
[9]   Effect of continuous positive airway pressure on the risk of road accidents in sleep apnea patients [J].
Barbe, Ferran ;
Sunyer, Jordi ;
de la Pena, Andres ;
Pericas, Jordi ;
Mayoralas, Lola R. ;
Maria Anto, Josep ;
Agusti, Alvar G. N. .
RESPIRATION, 2007, 74 (01) :44-49
[10]   Effect of nasal continuous positive airway pressure treatment on blood pressure in patients with obstructive sleep apnea [J].
Becker, HF ;
Jerrentrup, A ;
Ploch, T ;
Grote, L ;
Penzel, T ;
Sullivan, CE ;
Peter, JH .
CIRCULATION, 2003, 107 (01) :68-73