Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications

被引:1227
作者
McCollough, Cynthia H. [1 ]
Leng, Shuai [1 ]
Yu, Lifeng [1 ]
Fletcher, Joel G. [1 ]
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
基金
美国国家卫生研究院;
关键词
ENERGY-COMPUTED-TOMOGRAPHY; VIRTUAL NONENHANCED IMAGES; ACID RENAL STONES; X-RAY-DETECTORS; LUNG PERFUSION; URIC-ACID; BONE REMOVAL; MULTIDETECTOR CT; NOISE-REDUCTION; AUTOMATIC BONE;
D O I
10.1148/radiol.2015142631
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In x-ray computed tomography (CT), materials having different elemental compositions can be represented by identical pixel values on a CT image (ie, CT numbers), depending on the mass density of the material. Thus, the differentiation and classification of different tissue types and contrast agents can be extremely challenging. In dual-energy CT, an additional attenuation measurement is obtained with a second x-ray spectrum (ie, a second "energy"), allowing the differentiation of multiple materials. Alternatively, this allows quantification of the mass density of two or three materials in a mixture with known elemental composition. Recent advances in the use of energy-resolving, photon-counting detectors for CT imaging suggest the ability to acquire data in multiple energy bins, which is expected to further improve the signal-to-noise ratio for material-specific imaging. In this review, the underlying motivation and physical principles of dualor multi-energy CT are reviewed and each of the current technical approaches is described. In addition, current and evolving clinical applications are introduced. (C)RSNA, 2015
引用
收藏
页码:637 / 653
页数:17
相关论文
共 99 条
[1]   ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY [J].
ALVAREZ, RE ;
MACOVSKI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :733-744
[2]   Stone-Targeted Dual-Energy CT: A New Diagnostic Approach to Urinary Calculosis [J].
Ascenti, Giorgio ;
Siragusa, Carmelo ;
Racchiusa, Sergio ;
Ielo, Isidora ;
Privitera, Giambattista ;
Midili, Federica ;
Mazziotti, Silvio .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (04) :953-958
[3]   The Medipix3RX: a high resolution, zero dead-time pixel detector readout chip allowing spectroscopic imaging [J].
Ballabriga, R. ;
Alozy, J. ;
Blaj, G. ;
Campbell, M. ;
Fiederle, M. ;
Frojdh, E. ;
Heijne, E. H. M. ;
Llopart, X. ;
Pichotka, M. ;
Procz, S. ;
Tlustos, L. ;
Wong, W. .
JOURNAL OF INSTRUMENTATION, 2013, 8
[4]   Renal Stone Assessment with Dual-Energy Multidetector CT and Advanced Postprocessing Techniques: Improved Characterization of Renal Stone Composition-Pilot Study [J].
Boll, Daniel T. ;
Patil, Neil A. ;
Paulson, Erik K. ;
Merkle, Elmar M. ;
Simmons, W. Neal ;
Pierre, Sean A. ;
Preminger, Glenn M. .
RADIOLOGY, 2009, 250 (03) :813-820
[5]   Dual-Energy CTA with Bone Removal for Transcranial Arteries: Intraindividual Comparison with Standard CTA without Bone Removal and TOF-MRA [J].
Buerke, Boris ;
Wittkamp, Gunnar ;
Med, Cand ;
Seifarth, Harald ;
Heindel, Walter ;
Kloska, Stephan P. .
ACADEMIC RADIOLOGY, 2009, 16 (11) :1348-1355
[6]   LEAST-SQUARES APPROACH IN MEASUREMENT-DEPENDENT FILTERING FOR SELECTIVE MEDICAL IMAGES [J].
CAO, QZ ;
BROSNAN, T ;
MACOVSKI, A ;
NISHIMURA, D .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1988, 7 (02) :154-160
[7]  
Carmi R, 2005, IEEE NUCL SCI CONF R, P1876
[8]   Prior image constrained compressed sensing (PICCS): A method to accurately reconstruct dynamic CT images from highly undersampled projection data sets [J].
Chen, Guang-Hong ;
Tang, Jie ;
Leng, Shuai .
MEDICAL PHYSICS, 2008, 35 (02) :660-663
[9]   Atherosclerotic Plaque Composition: Analysis with Multicolor CT and Targeted Gold Nanoparticles [J].
Cormode, David P. ;
Roessl, Ewald ;
Thran, Axel ;
Skajaa, Torjus ;
Gordon, Ronald E. ;
Schlomka, Jens-Peter ;
Fuster, Valentin ;
Fisher, Edward A. ;
Mulder, Willem J. M. ;
Proksa, Roland ;
Fayad, Zahi A. .
RADIOLOGY, 2010, 256 (03) :774-782
[10]   SINGLE-EXPOSURE DUAL-ENERGY COMPUTED RADIOGRAPHY - IMPROVED DETECTION AND PROCESSING [J].
ERGUN, DL ;
MISTRETTA, CA ;
BROWN, DE ;
BYSTRIANYK, RT ;
SZE, WK ;
KELCZ, F ;
NAIDICH, DP .
RADIOLOGY, 1990, 174 (01) :243-249