共 68 条
Mesostructured silica chemically doped with RuII as a superior optical oxygen sensor
被引:205
作者:
Lei, Bingfu
[1
]
Li, Bin
Zhang, Haoran
Lu, Shaozhe
Zheng, Zhuhong
Li, Wenlian
Wang, Yue
机构:
[1] Chinese Acad Sci, Changchun Inst Opt Fine Mech & Phys, Key Lab Excited State Proc, Changchun 130033, Peoples R China
[2] Chinese Acad Sci, Grad Sch, Changchun 130033, Peoples R China
[3] Jilin Univ, Minist Educ, Key Lab Supramol Struct & Mat, Changchun 130012, Peoples R China
关键词:
D O I:
10.1002/adfm.200500737
中图分类号:
O6 [化学];
学科分类号:
0703 ;
摘要:
Novel oxygen sensors consisting of a [Ru(bpy)(2)phen](2+) (bpy: 2,2'-bipyridyl, phen: phenathroline) portion covalently grafted to a mesostructured silica-based network are prepared in situ via a sol-gel approach with the help of cetyltrimethylammonium-bromide (CTAB) surfactant. 1,10-Phenanthroline covalently grafted to 3-(triethoxysilyl)propyl isocyanate is used as not only the sol-gel precursor but also as the second ligand of the Ru(bpy)(2)Cl-2 center dot 2H(2)O complex to prepare the sol-gel-derived mesostructured silicates for an oxygen sensor. For comparison purposes, the oxygen sensors in which [Ru(bpy)(2)phen]Cl-2 is conventionally physically incorporated into the matrix are also prepared. Elemental analysis, NMR, Fourier transform IR, UV-vis electronic absorption, luminescence-intensity quenching Stern-Volmer plots, and excited-state decay analysis are used to characterize the obtained oxygen sensors. These obtained bulk xerogels and spin-coated thin films show that the homogeneity and the sensitivity of the covalently grafted samples are superior to those of the physically incorporated ones, and the highest sensitivity is obtained in the mesostructured bulk xerogel. This improvement in oxygen sensitivity is attributed to the increased diffusivity of oxygen in the uniform and nearly parallel porous structure of the Mobil Catalytic Material 41 mesostructured matrix, the enhanced homogeneity results from the covalently grafted propyl group in -Si-(CH2)(3)- that acts as the fundamental spacer which prevents interaction between the attached Run complex and the silica matrix, and optimal dispersion in the mesopores during the sol-gel polycondensation. Furthermore, the greatly minimized leaching effect of the sensing molecules could be observed in the covalently grafted system. The covalent grafting strategy presented in this paper provides superior optical oxygen sensors with homogeneous distribution, improved sensitivity, and simplified calibration plots.
引用
收藏
页码:1883 / 1891
页数:9
相关论文