Differences in the time course of proximal and distal airway response to inhaled histamine studied by synchrotron radiation CT

被引:23
作者
Bayat, S
Porra, L
Suhonen, H
Nemoz, C
Suortti, P
Sovijärvi, ARA
机构
[1] Ctr Hosp St Laurent Du Pont, F-38380 Saint Laurent Du Pont, France
[2] European Synchrotron Radiat Facil, Med Beamline ID17, Grenoble, France
[3] Univ Helsinki, Dept Phys Sci, Helsinki, Finland
[4] Univ Helsinki, Cent Hosp, Dept Clin Physiol & Nucl Med, Helsinki, Finland
关键词
bronchoconstriction; xenon; computed tomography; X-ray; rabbit;
D O I
10.1152/japplphysiol.00594.2005
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
We studied the kinetics of proximal and distal bronchial response to histamine aerosol in healthy anesthetized and mechanically ventilated rabbits up to 60 min after histamine administration using a novel xenon-enhanced synchrotron radiation computed tomography imaging technique. Individual proximal airway constriction was assessed by measuring the luminal cross-sectional area. Distal airway obstruction was estimated by measuring the ventilated alveolar area after inhaled xenon administration. Respiratory system conductance was assessed continuously. Proximal airway cross-sectional area decreased by 57% of the baseline value by 20 min and recovered gradually but incompletely within 60 min. The ventilated alveolar area decreased immediately after histamine inhalation by 55% of baseline value and recovered rapidly thereafter. The results indicate that the airway reaction to inhaled histamine and the subsequent recovery are significantly slower in proximal than in distal bronchi in healthy rabbit. The findings suggest that physiological reaction mechanisms to inhaled histamine in the airway walls of large and small bronchi are not similar.
引用
收藏
页码:1964 / 1973
页数:10
相关论文
共 46 条
[1]   ASSESSMENT OF METHACHOLINE-INDUCED AIRWAY CONSTRICTION BY ULTRAFAST HIGH-RESOLUTION COMPUTED-TOMOGRAPHY [J].
AMIRAV, I ;
KRAMER, SS ;
GRUNSTEIN, MM ;
HOFFMAN, EA .
JOURNAL OF APPLIED PHYSIOLOGY, 1993, 75 (05) :2239-2250
[2]   Increased airway resistance during xenon anaesthesia in pigs is attributed to physical properties of the gas [J].
Baumert, JH ;
Reyle-Hahn, M ;
Hecker, K ;
Tenbrinck, R ;
Kuhlen, R ;
Rossaint, R .
BRITISH JOURNAL OF ANAESTHESIA, 2002, 88 (04) :540-545
[3]   Quantitative functional lung imaging with synchrotron radiation using inhaled xenon as contrast agent [J].
Bayat, S ;
Le Duc, G ;
Porra, L ;
Berruyer, G ;
Nemoz, C ;
Monfraix, S ;
Fiedler, S ;
Thomlinson, W ;
Suortti, P ;
Standertskjöld-Nordenstam, CG ;
Sovijärvi, ARA .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (12) :3287-3299
[4]   EFFECTS OF INCREASED BRONCHIAL BLOOD-FLOW ON AIRWAY MORPHOMETRY, RESISTANCE, AND REACTIVITY [J].
BLOSSER, S ;
MITZNER, W ;
WAGNER, EM .
JOURNAL OF APPLIED PHYSIOLOGY, 1994, 76 (04) :1624-1629
[5]   The myth of maximal airway responsiveness in vivo [J].
Brown, RH ;
Mitzner, W .
JOURNAL OF APPLIED PHYSIOLOGY, 1998, 85 (06) :2012-2017
[6]   INDIVIDUAL AIRWAY CONSTRICTOR RESPONSE HETEROGENEITY TO HISTAMINE ASSESSED BY HIGH-RESOLUTION COMPUTED-TOMOGRAPHY [J].
BROWN, RH ;
HEROLD, CJ ;
HIRSHMAN, CA ;
ZERHOUNI, EA ;
MITZNER, W .
JOURNAL OF APPLIED PHYSIOLOGY, 1993, 74 (06) :2615-2620
[7]   AIRWAY EDEMA POTENTIATES AIRWAY REACTIVITY [J].
BROWN, RH ;
ZERHOUNI, EA ;
MITZNER, W .
JOURNAL OF APPLIED PHYSIOLOGY, 1995, 79 (04) :1242-1248
[8]   Individual canine airways responsiveness to aerosol histamine and methacholine in vivo [J].
Brown, RH ;
Georgakopoulos, J ;
Mitzner, W .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1998, 157 (02) :491-497
[9]   RELEVANCE OF CLASSIFICATION BY SIZE TO TOPOGRAPHICAL DIFFERENCES IN BRONCHIAL SMOOTH-MUSCLE RESPONSE [J].
CHITANO, P ;
SIGURDSSON, SB ;
HALAYKO, AJ ;
STEPHENS, NL .
JOURNAL OF APPLIED PHYSIOLOGY, 1993, 75 (05) :2013-2021
[10]   CHANGES IN TRACHEAL MUCOSAL THICKNESS AND BLOOD-FLOW IN SHEEP [J].
CORFIELD, DR ;
HANAFI, Z ;
WEBBER, SE ;
WIDDICOMBE, JG .
JOURNAL OF APPLIED PHYSIOLOGY, 1991, 71 (04) :1282-1288