Study of the double-pulse setup with an orthogonal beam geometry for laser-induced breakdown spectroscopy

被引:89
|
作者
Gautier, C
Fichet, P
Menut, D
Lacour, JL
L'Hermite, D
Dubessy, J
机构
[1] CEA Saclay, Nucl Energy Div, LRSI, F-91191 Gif Sur Yvette, France
[2] Univ Nancy 1, CREGU G2R, UMR 7566, F-54501 Vandoeuvre Les Nancy, France
关键词
laser-induced breakdown spectroscopy (LIBS); double-pulse; aluminum; Echelle spectrometer;
D O I
10.1016/j.sab.2004.05.002
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
single- and double-pulse laser-induced breakdown spectroscopy (LIBS) was applied on aluminum samples at atmospheric pressure in air. In the case of the double-pulse scheme, experiments were carried out with an ablation laser emitting at 532 nm and a reheating laser emitting at 1064 nm in an orthogonal beam geometry. With the use of a 1-m focal length monochromator and an echelle spectrometer both equipped with an intensified charge coupled device (ICCD), the studies on the effect of the delay between the two laser pulses displayed optimum enhancements of line emissions only at 200 ns in the reheating scheme developed here. The experimental parameters, like the signal acquisition delay, were largely studied. The line intensity enhancements were also investigated in dependence on physical parameters, such as the excitation energy levels of the lines observed. Moreover, the relative importance of ionic and neutral lines in the emission spectra was precisely characterized. From the different investigations, the behaviors of the line emissions towards the double-pulse technique were related to their excitation energy levels. A correlation between the increases in intensity and the excitation energy levels of the line emissions was highlighted. As a result, the reheating scheme showed improvements of sensitivity for elements emitting ionic lines compared with the corresponding single-pulse experiments. (C) 2004 Elsevier B.V All rights reserved.
引用
收藏
页码:975 / 986
页数:12
相关论文
共 50 条
  • [21] Depth profiles of ceramic tiles by using orthogonal double-pulse laser induced breakdown spectrometry
    Ctvrtnickova, T.
    Fortes, F. J.
    Cabalin, L. M.
    Kanicky, V.
    Laserna, J. J.
    SURFACE AND INTERFACE ANALYSIS, 2009, 41 (09) : 714 - 719
  • [22] In situ analysis of magnesium alloy using a standoff and double-pulse laser-induced breakdown spectroscopy system
    Xin, Yong
    Sun, Lan-Xiang
    Yang, Zhi-Jia
    Zeng, Peng
    Cong, Zhi-Bo
    Qi, Li-Feng
    FRONTIERS OF PHYSICS, 2016, 11 (05)
  • [23] Influence of ambient gas pressure on laser-induced breakdown spectroscopy technique in the parallel double-pulse configuration
    Cristoforetti, G
    Legnaioli, S
    Palleschi, V
    Salvetti, A
    Tognoni, E
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (12) : 1907 - 1917
  • [24] In situ analysis of magnesium alloy using a standoff and double-pulse laser-induced breakdown spectroscopy system
    Yong Xin
    Lan-Xiang Sun
    Zhi-Jia Yang
    Peng Zeng
    Zhi-Bo Cong
    Li-Feng Qi
    Frontiers of Physics, 2016, 11
  • [25] Quantitative Analysis of Nutrient Elements in Soil Using Single and Double-Pulse Laser-Induced Breakdown Spectroscopy
    He, Yong
    Liu, Xiaodan
    Lv, Yangyang
    Liu, Fei
    Peng, Jiyu
    Shen, Tingling
    Zhao, Yun
    Tang, Yu
    Luo, Shaoming
    SENSORS, 2018, 18 (05)
  • [26] Quantitative analysis of Pb in soil by femtosecond-nanosecond double-pulse laser-induced breakdown spectroscopy
    Zhao, Shangyong
    Song, Chao
    Gao, Xun
    Lin, Jingquan
    RESULTS IN PHYSICS, 2019, 15
  • [27] Concentric multipass cell enhanced double-pulse laser-induced breakdown spectroscopy for sensitive elemental analysis
    Bai, Yu
    Zhang, Lei
    Hou, Jiajia
    Zhao, Yang
    Ma, Weiguang
    Dong, Lei
    Yin, Wangbao
    Xiao, Liantuan
    Jia, Suotang
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2020, 168
  • [28] Double pulse laser-induced breakdown spectroscopy with femtosecond laser pulses
    Pinon, V.
    Fotakis, C.
    Nicolas, G.
    Anglos, D.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2008, 63 (10) : 1006 - 1010
  • [29] Measurement of chlorine concentration on steel surfaces via fiber-optic laser-induced breakdown spectroscopy in double-pulse configuration
    Xiao, X.
    Le Berre, S.
    Fobar, D. G.
    Burger, M.
    Skrodzki, P. J.
    Hartig, K. C.
    Motta, A. T.
    Jovanovic, I.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2018, 141 : 44 - 52
  • [30] Comparison of detection limits, for two metallic matrices, of laser-induced breakdown spectroscopy in the single and double-pulse configurations
    Marwa A. Ismail
    Gabriele Cristoforetti
    Stefano Legnaioli
    Lorenzo Pardini
    Vincenzo Palleschi
    Azenio Salvetti
    Elisabetta Tognoni
    Mohamed A. Harith
    Analytical and Bioanalytical Chemistry, 2006, 385 : 316 - 325