Load Sharing and Ligament Strains in Balanced, Overstuffed and Understuffed UKA. A Validated Finite Element Analysis

被引:69
作者
Innocenti, Bernardo [1 ,2 ]
Bilgen, Omer Faruk [3 ]
Labey, Luc [1 ]
van Lenthe, G. Harry [4 ]
Sloten, Jos Vander [4 ]
Catani, Fabio [5 ]
机构
[1] Smith&Nephew, European Ctr Knee Res, Leuven, Belgium
[2] Univ Libre Bruxelles, BEAMS Dept, B-1050 Brussels, Belgium
[3] Uludag Univ, Sch Med, Dept Orthopaedia, Bursa, Turkey
[4] Katholieke Univ Leuven, Biomech Sect, Leuven, Belgium
[5] Modena Policlin, Orthopaed & Traumatol Dept, Modena, Italy
关键词
UKA; overstuffing; understuffing; tibial stress; collateral ligament strain; UNICOMPARTMENTAL KNEE ARTHROPLASTY; FOLLOW-UP; NUMERICAL SENSITIVITY; 3-DIMENSIONAL MODEL; JOINT REPLACEMENT; STRESS-ANALYSIS; TIBIAL PLATEAU; EARLY FAILURE; 10-YEAR; BEHAVIOR;
D O I
10.1016/j.arth.2014.01.020
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The aim of this study was to quantify the effects of understuffing and overstuffing UKA on bone stresses, load distribution and ligament strains. For that purpose, a numerical knee model of a cadaveric knee was developed and was validated against experimental measurements on that same knee. Good agreement was found among the numerical and experimental results. This study showed that, even if a medial UKA is well-aligned with normal soft tissue tension and with correct thickness of the tibia component, it induces a stiffness modification in the joint that alters the load distribution between the medial and lateral compartments, the bone stress and the ligament strain potentially leading to an osteoarthritic progression. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:1491 / 1498
页数:8
相关论文
共 58 条
[1]   Early failure of unicompartmental knee arthroplasty leading to revision [J].
Aleto, Thomas J. ;
Berend, Michael E. ;
Ritter, Merrill A. ;
Faris, Philip M. ;
Meneghini, R. Michael .
JOURNAL OF ARTHROPLASTY, 2008, 23 (02) :159-163
[2]  
Arnout N, 2013, ACTA ORTHOP BELG, V79, P435
[3]   A three-dimensional finite element stress analysis for tunnel placement and buttons in anterior cruciate ligament reconstructions [J].
Au, AG ;
Raso, VJ ;
Liggins, AB ;
Otto, DD ;
Amirfazli, A .
JOURNAL OF BIOMECHANICS, 2005, 38 (04) :827-832
[4]   EPIPHYSEAL-BASED DESIGNS FOR TIBIAL PLATEAU COMPONENTS .2. STRESS-ANALYSIS IN THE SAGITTAL PLANE [J].
BEAUPRE, GS ;
VASU, R ;
CARTER, DR ;
SCHURMAN, DJ .
JOURNAL OF BIOMECHANICS, 1986, 19 (08) :663-673
[5]  
Bendjaballah M., 1995, Knee, V2, P69, DOI [10.1016/0968-0160(95)00018-K, DOI 10.1016/0968-0160(95)00018-K]
[6]  
Berger RA, 1999, CLIN ORTHOP RELAT R, P50
[7]   Results of unicompartmental knee arthroplasty at a minimum of ten years of follow-up [J].
Berger, RA ;
Meneghini, RM ;
Jacobs, JJ ;
Sheinkop, MB ;
Della Valle, CJ ;
Rosenberg, AG ;
Galante, JO .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (05) :999-1006
[8]   LIGAMENT-BONE INTERACTION IN A 3-DIMENSIONAL MODEL OF THE KNEE [J].
BLANKEVOORT, L ;
HUISKES, R .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1991, 113 (03) :263-269
[9]   Unicompartmental knee arthroplasty [J].
Borus, Todd ;
Thornhill, Thomas .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2008, 16 (01) :9-18
[10]   Impact of osteoarthritis on individuals and society: how much disability? Social consequences and health economic implications [J].
Brooks, PM .
CURRENT OPINION IN RHEUMATOLOGY, 2002, 14 (05) :573-577