Production of Annealed Cold-Sprayed 316L Stainless Steel Coatings for Biomedical Applications and Their in-vitro Corrosion Response

被引:33
作者
Dikici, Burak [1 ]
Topuz, Mehmet [2 ]
机构
[1] Ataturk Univ, Dept Met & Mat Engn, TR-25240 Erzurum, Turkey
[2] Yuzuncu Yil Univ, Dept Mech Engn, TR-65080 Van, Turkey
关键词
biomaterials; cold spray; 316L; corrosion; heat treatment; MECHANICAL-PROPERTIES; HEAT-TREATMENT; MICROSTRUCTURE; TITANIUM; BEHAVIOR; ALLOY;
D O I
10.1134/S2070205118020168
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
316L powders were successfully deposited onto Al5052 aluminium substrates by cold spray method. Annealing was treated on the coated samples at 250-1000A degrees C temperatures under Ar atmosphere. The in vitro performances of the coatings have been compared with using electrochemical corrosion test technique in the simulated body fluid (SBF) at body temperature (37A degrees C). A scanning electron microscope (SEM-EDS) and X-ray diffraction (XRD) have been used for microstructural characterization and phases identifications of the coatings, respectively. The results were shown that there are high adhesions at particle and substrate interfaces and between the particles deposited as well. Also, the increasing annealing temperature increases corrosion resistance of the cold sprayed 316L stainless steel coatings. The corrosion susceptibility of the coating annealed at 1000A degrees C was similar that of standard 316L stainless steel implant material in Ringer's solution. The microstructural observations revealed that corrosion starts between the inter-splat powders and continues throughout the surface not in-depth.
引用
收藏
页码:333 / 339
页数:7
相关论文
共 23 条
[1]   Reconstructing the human body using biomaterials [J].
Agrawal, CM .
JOM-JOURNAL OF THE MINERALS METALS & MATERIALS SOCIETY, 1998, 50 (01) :31-35
[2]   The Effect of Coating Thickness on Corrosion Resistance of Hydroxyapatite Coated Ti6Al4V and 316L SS Implants [J].
Aksakal, B. ;
Gavgali, M. ;
Dikici, B. .
JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2010, 19 (06) :894-899
[3]   Fatigue behavior of annealed cold-sprayed 316L stainless steel coating for biomedical applications [J].
AL-Mangour, B. ;
Dallala, R. ;
Zhim, F. ;
Mongrain, R. ;
Yue, S. .
MATERIALS LETTERS, 2013, 91 :352-355
[4]   Improving the strength and corrosion resistance of 316L stainless steel for biomedical applications using cold spray [J].
AL-Mangour, Bandar ;
Mongrain, Rosaire ;
Irissou, Eric ;
Yue, Stephen .
SURFACE & COATINGS TECHNOLOGY, 2013, 216 :297-307
[5]   The Effect of Post-Heat Treatment on Microstructure of 316L Cold-Sprayed Coatings and Their Corrosion Performance [J].
Dikici, B. ;
Yilmazer, H. ;
Ozdemir, I. ;
Isik, M. .
JOURNAL OF THERMAL SPRAY TECHNOLOGY, 2016, 25 (04) :704-714
[6]  
Dikici B, 2015, SPRING SER BIOMAT S, V3, P275, DOI 10.1007/978-3-662-46836-4_12
[7]  
Karlsson M, 2004, THESIS
[8]   Improvement of hydroxyapatite sol-gel coating on titanium with ammonium hydroxide addition [J].
Kim, HW ;
Kim, HE ;
Kim, HW ;
Knowles, JC .
JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 2005, 88 (01) :154-159
[9]   Characterization and corrosion behavior of hydroxyapatite coatings on Ti6Al4V fabricated by electrophoretic deposition [J].
Kwok, C. T. ;
Wong, P. K. ;
Cheng, F. T. ;
Man, H. C. .
APPLIED SURFACE SCIENCE, 2009, 255 (13-14) :6736-6744
[10]   Studies on calcium phosphate coatings [J].
Lee, IS ;
Kim, HE ;
Kim, SY .
SURFACE & COATINGS TECHNOLOGY, 2000, 131 (1-3) :181-186