Simulation of coupled heat and moisture transfer in air-conditioned buildings

被引:46
|
作者
Qin, Menghao [1 ,2 ]
Belarbi, Rafik [3 ]
Ait-Mokhtar, Abdelkarim [3 ]
Allard, Francis [3 ]
机构
[1] Nanjing Univ, Sch Architecture, Nanjing, Peoples R China
[2] NIST, Gaithersburg, MD 20899 USA
[3] La Rochelle Univ, LEPTAB, La Rochelle, France
关键词
Modeling; Heat and moisture transfer; Simulation; Building energy;
D O I
10.1016/j.autcon.2008.12.006
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The simultaneous heat and moisture transfer in the building envelope has an important influence on the indoor environment and the overall performance of buildings. In this paper, a model for predicting whole building heat and moisture transfer was presented. Both heat and moisture transfer in the building envelope and indoor air were simultaneously considered; their interactions were modeled. The coupled model takes into account most of the main hygrothermal effects in buildings. The coupled system model was implemented in MATLAB-Simulink, and validated by using a series of published testing tools. The new program was applied to investigate the moisture transfer effect on indoor air humidity and building energy consumption under different climates. The results show that the use of more detailed simulation routines can result in improvements to the building's design for energy optimisation through the choice of proper hygroscopic materials, which would not be indicated by simpler calculation techniques. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:624 / 631
页数:8
相关论文
共 50 条
  • [21] Efficient use of waste heat in air-conditioned and process air
    Amberg, Jens
    Euroheat and Power/Fernwarme International, 2020, 49 (03): : 70 - 71
  • [22] Recurrent exposure to Histoplasma capsulatum in modern air-conditioned buildings
    Luby, JP
    Southern, PM
    Haley, CE
    Vahle, KL
    Munford, RS
    Haley, RW
    CLINICAL INFECTIOUS DISEASES, 2005, 41 (02) : 170 - 176
  • [23] Implication of global warming on air-conditioned office buildings in Australia
    Guan, Lisa
    BUILDING RESEARCH AND INFORMATION, 2009, 37 (01): : 43 - 54
  • [24] Ten Tips for Energy-Efficient Air-Conditioned Buildings
    Khalil, Essam E.
    PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, DETC 2010, VOL 3, A AND B, 2010, : 733 - 739
  • [25] An analysis of coupled heat and moisture transfer in buildings considering the influence of radiant heat transfer
    Matsumoto, M
    Hokoi, S
    Ka, E
    ASHRAE TRANSACTIONS 1997, VOL 103, PT I, 1997, 103 : 573 - 583
  • [26] Dynamic evaluation of thermal comfort environment of air-conditioned buildings
    Wang Hanqing
    Huang Chunhua
    Liu Zhiqiang
    Tang Guangfa
    Liu Yingyun
    Wang Zhiyong
    BUILDING AND ENVIRONMENT, 2006, 41 (11) : 1522 - 1529
  • [27] Performance of noise indices in air-conditioned landscaped office buildings
    Tang, SK
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1997, 102 (03): : 1657 - 1663
  • [28] An efficient numerical model for the simulation of coupled heat, air, and moisture transfer in porous media
    Berger, Julien
    Dutykh, Denys
    Mendes, Nathan
    Gosse, Laurent
    ENGINEERING REPORTS, 2020, 2 (02)
  • [29] Coupled heat air and moisture transfer in building structures
    Haupl, P
    Grunewald, J
    Fechner, H
    Stopp, H
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1997, 40 (07) : 1633 - 1642
  • [30] Indoor air quality and energy performance of air-conditioned office buildings in Singapore
    Sekhar, SC
    Tham, KW
    Cheong, KW
    INDOOR AIR, 2003, 13 (04) : 315 - 331