Imaging of transcatheter aortic valve replacement complications

被引:3
作者
Naik, M. [1 ]
McNamara, C. [1 ]
Jabbour, R. J. [2 ]
Gopalan, D. [1 ]
Mikhail, G. W. [2 ]
Mirsadraee, S. [3 ]
Ariff, B. [1 ]
机构
[1] Hammersmith Hosp, Dept Radiol, Du Cane Rd, London W12 0HS, England
[2] Hammersmith Hosp, Dept Cardiol, Du Cane Rd, London W12 0HS, England
[3] Harefield Hosp, Dept Radiol, Hill End Rd, Uxbridge UB9 6JH, Middx, England
关键词
PARAVALVULAR REGURGITATION; CORONARY OBSTRUCTION; CEREBROVASCULAR EVENTS; PERMANENT PACEMAKER; MAGNETIC-RESONANCE; CLINICAL-OUTCOMES; IMPLANTATION TAVI; ACCESS; CT; STENOSIS;
D O I
10.1016/j.crad.2019.12.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aortic stenosis is increasing in incidence and is now commonly managed with transcatheter aortic valve replacement (TAVR) in intermediate and high-risk patients. Radiologists are likely to encounter patients undergoing this procedure both pre- and postoperatively, and therefore, an understanding of procedural complications is essential. Complications may relate to the access site or approach, or the valve itself. This article will review the most common complications described in literature and focuses on the role of multidetector computed tomography (CT) in their evaluation either exclusively, or complementary to other imaging methods. (C) 2019 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:27 / 37
页数:11
相关论文
共 75 条
[1]   Aortic regurgitation after transcatheter aortic valve implantation: incidence and early outcome. Results from the German transcatheter aortic valve interventions registry [J].
Abdel-Wahab, Mohamed ;
Zahn, Ralf ;
Horack, Martin ;
Gerckens, Ulrich ;
Schuler, Gerhard ;
Sievert, Horst ;
Eggebrecht, Holger ;
Senges, Jochen ;
Richardt, Gert .
HEART, 2011, 97 (11) :899-906
[2]   SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR) [J].
Achenbach, Stephan ;
Delgado, Victoria ;
Hausleiter, Joerg ;
Schoenhagen, Paul ;
Min, James K. ;
Leipsic, Jonathon A. .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (06) :366-380
[3]   Comparison of Two- and Three-Dimensional Transthoracic Echocardiography to Cardiac Magnetic Resonance Imaging for Assessment of Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation [J].
Altiok, Ertunc ;
Frick, Michael ;
Meyer, Christian G. ;
Al Ateah, Ghazi ;
Napp, Andreas ;
Kirschfink, Annemarie ;
Almalla, Mohammad ;
Lotfi, Shahran ;
Becker, Michael ;
Herich, Lena ;
Lehmacher, Walter ;
Hoffmann, Rainer .
AMERICAN JOURNAL OF CARDIOLOGY, 2014, 113 (11) :1859-1866
[4]   Predictors of Early Cerebrovascular Events in Patients With Aortic Stenosis Undergoing Transcatheter Aortic Valve Replacement [J].
Auffret, Vincent ;
Regueiro, Ander ;
Del Trigo, Maria ;
Altisent, Omar Abdul-Jawad ;
Campelo-Parada, Francisco ;
Chiche, Olivier ;
Puri, Rishi ;
Rodes-Cabau, Josep .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (07) :673-684
[5]   Anatomical and Procedural Features Associated With Aortic Root Rupture During Balloon-Expandable Transcatheter Aortic Valve Replacement [J].
Barbanti, Marco ;
Yang, Tae-Hyun ;
Cabau, Josep Rodes ;
Tamburino, Corrado ;
Wood, David A. ;
Jilaihawi, Hasan ;
Blanke, Phillip ;
Makkar, Raj R. ;
Latib, Azeem ;
Colombo, Antonio ;
Tarantini, Giuseppe ;
Raju, Rekha ;
Binder, Ronald K. ;
Nguyen, Giang ;
Freeman, Melanie ;
Ribeiro, Henrique B. ;
Kapadia, Samir ;
Min, James ;
Feuchtner, Gudrun ;
Gurtvich, Ronen ;
Alqoofi, Faisal ;
Pelletier, Marc ;
Ussia, Gian Paolo ;
Napodano, Massimo ;
de Brito, Fabio Sandoli ;
Kodali, Susheel ;
Norgaard, Bjarne L. ;
Hansson, Nicolaj C. ;
Pache, Gregor ;
Canovas, Sergio J. ;
Zhang, Hongbin ;
Leon, Martin B. ;
Webb, John G. ;
Leipsic, Jonathon .
CIRCULATION, 2013, 128 (03) :244-253
[6]   Access Sites for TAVI: Patient Selection Criteria, Technical Aspects, and Outcomes [J].
Biasco, Luigi ;
Ferrari, Enrico ;
Pedrazzini, Giovanni ;
Faletra, Francesco ;
Moccetti, Tiziano ;
Petracca, Francesco ;
Moccetti, Marco .
FRONTIERS IN CARDIOVASCULAR MEDICINE, 2018, 5
[7]   Computed tomography imaging in the context of transcatheter aortic valve implantation (TAVI) / transcatheter aortic valve replacement (TAVR): An expert consensus document of the Society of Cardiovascular Computed Tomography [J].
Blanke, Philipp ;
Weir-McCall, Jonathan R. ;
Achenbach, Stephan ;
Delgado, Victoria ;
Hausleiter, Joerg ;
Jilaihawi, Hasan ;
Marwan, Mohamed ;
Norgaard, Bjarne L. ;
Piazza, Niccolo ;
Schoenhagen, Paul ;
Leipsic, Jonathon A. .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2019, 13 (01) :1-20
[8]   CT in Transcatheter Aortic Valve Replacement [J].
Blanke, Philipp ;
Schoepf, U. Joseph ;
Leipsic, Jonathon A. .
RADIOLOGY, 2013, 269 (03) :650-669
[9]   Prosthesis Oversizing in Balloon-Expandable Transcatheter Aortic Valve Implantation Is Associated With Contained Rupture of the Aortic Root [J].
Blanke, Philipp ;
Reinoehl, Jochen ;
Schlensak, Christian ;
Siepe, Matthias ;
Pache, Gregor ;
Euringer, Wulf ;
Geibel-Zehender, Annette ;
Bode, Christopher ;
Langer, Mathias ;
Beyersdorf, Friedhelm ;
Zehender, Manfred .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (04) :540-548
[10]   A Practical Guide to Multimodality Imaging of Transcatheter Aortic Valve Replacement [J].
Bloomfield, Gerald S. ;
Gillam, Linda D. ;
Hahn, Rebecca T. ;
Kapadia, Samir ;
Leipsic, Jonathon ;
Lerakis, Stamatios ;
Tuzcu, Murat ;
Douglas, Pamela S. .
JACC-CARDIOVASCULAR IMAGING, 2012, 5 (04) :441-455