Aim. The aim of this paper was to report our preliminary experience in outcome, safety and mid-term results in the treatment of thoracoabdominal aortic aneurysms (TAAA) with a novel multibranchstentgraft (E-xtra DESIGN ENGINEERING, JOTEC, Germany). Methods. Eight patients (mean age 66 years, 2 female) with TAAA (Crawford type I: 2 cases, type III: 3 cases, type IV: 3 cases), mean aneurysm diameter 61 mm, growth over 5 nun per year were treated. Implantation was performed under general anesthesia and surgical exposition of the common femoral artery. Brachial access was percutaneous in 5/8 patients. Balloon-expandable (Advanta V12) bridging stent-grafts were employed and lined with self-expanding nitinol stents. All patients except type IV TAAA received a spinal drainage catheter. Results. The device was successfully deployed in 8/8 patients. 29/32 visceral branches were engaged. One stenosed celiac trunk was left untreated without further consequences, two renal arteries which could not be cannulated were revascularized with iliorenal bypass. One patient needed surgical revision of groin hematoma, one patient suffered from permanent protopathic sensory deficit. No renal complications occurred. Since the primary implantation was deliberately kept short and amount of contrast agent was minimised, four patients needed a secondary percutaneous procedure (Palmaz stent implantation for type I endoleak, re-PTA or additional bridging stent-graft implantation for type III endoleak). The assisted primary success rate was 8/8. Mean follow-up was 18 months. Success was stable in 7/8 patients, one patient shows type V endoleak with 5mrn sac expansion. No mortality or complication occurred during follow-up. Conclusion. The JOTEC E-xtra DESIGN ENGINEERING multibranch stent-graft is a promising new candidate for endovascular TAAA treatment with sufficient safety and efficacy. Its short delivery time suggests its use in patients with rapid aneurysm growth or high anxiety.
引用
收藏
页码:543 / 550
页数:8
相关论文
共 50 条
  • [11] Six-year experience with talent stent-graft repair of abdominal aortic aneurysms
    Espinosa, G
    Ribeiro, M
    Riguetti, C
    Caramalho, MF
    Mendes, WDS
    Santos, SR
    JOURNAL OF ENDOVASCULAR THERAPY, 2005, 12 (01) : 35 - 45
  • [12] Current results of total endovascular repair of thoracoabdominal aortic aneurysms
    Verzini, F.
    Loschi, D.
    De Rango, P.
    Ferrer, C.
    Simonte, G.
    Coscarella, C.
    Pogany, G.
    Cao, P.
    JOURNAL OF CARDIOVASCULAR SURGERY, 2014, 55 (01) : 9 - 19
  • [13] Stent graft types for endovascular repair of abdominal aortic aneurysms
    Duffy, James M. N.
    Rolph, Rachel
    Waltham, Matthew
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2015, (09):
  • [14] Early Results of Elective Endovascular Repair of Infrarenal Abdominal Aortic Aneurysms With the Minos™Stent-Graft System
    Pitoulias, Georgios A.
    Pitoulias, Apostolos G.
    Chatzelas, Dimitrios A.
    Zampaka, Theodosia
    Loutradis, Charalampos
    Potouridis, Anastasios
    Tachtsi, Maria D.
    JOURNAL OF ENDOVASCULAR THERAPY, 2025, 32 (01) : 225 - 232
  • [15] Juxtarenal aortic aneurysms: preliminary experience with fenestrated E-vita abdominal stent-graft
    Ricci, C.
    Ceccherini, C.
    Cini, M.
    Vigni, F.
    Leonini, S.
    Puliti, A.
    Benvenuti, A.
    Tucci, E.
    Tommasino, G.
    Muzzi, L.
    Neri, E.
    JOURNAL OF CARDIOVASCULAR SURGERY, 2013, 54 (04) : 491 - 497
  • [16] Total Endovascular Repair of Thoracoabdominal Aortic Aneurysms
    Clough, R. E.
    Modarai, B.
    Bell, R. E.
    Salter, R.
    Sabharwal, T.
    Taylor, P. R.
    Carrell, T. W.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2012, 43 (03) : 262 - 267
  • [17] Novel conformable stent-graft repair of abdominal aortic aneurysms with hostile neck anatomy: A single-centre experience
    Lee, Seong Hoon
    Melvin, Ross
    Kerr, Stacey
    Barakova, Lucie
    Wilson, Alasdair
    Renwick, Bryce
    VASCULAR, 2024, 32 (01) : 19 - 24
  • [18] Endovascular Repair Using a 7-Branch Stent-Graft for a Thoracoabdominal Aortic Aneurysm With Variant Renovisceral Artery Anatomy
    Eleshra, Ahmed
    Spanos, Konstantinos
    Panuccio, Giuseppe
    Gronert, Catharina
    Rohlffs, Fiona
    Koelbel, Tilo
    JOURNAL OF ENDOVASCULAR THERAPY, 2020, 27 (02) : 231 - 236
  • [19] Endovascular repair of abdominal aortic aneurysms in patients with severe angulation of the proximal neck using a flexible stent-graft: European Multicenter Experience
    Albertini, J. N.
    Perdikides, T.
    Soong, C. V.
    Hinchliffe, R. J.
    Trojanowksa, M.
    Yusuf, S. W.
    Clement, C.
    Hopkinson, B. R.
    JOURNAL OF CARDIOVASCULAR SURGERY, 2006, 47 (03) : 245 - 250
  • [20] Safety and Feasibility Study of a Novel Stent-Graft for Thoracic Endovascular Aortic Repair: a Canine Model Experiment
    Yang, Fan
    Qiu, Jiehua
    Fu, Zeliang
    Qiu, Yuchen
    Luo, Junrong
    Xiao, Qingyang
    Cao, Huabin
    BRAZILIAN JOURNAL OF CARDIOVASCULAR SURGERY, 2017, 32 (05) : 401 - 407