Endovascular repair of thoracoabdominal aortic aneurysms with a novel multibranch stent-graft design: preliminary experience

被引:0
|
作者
Kinstner, C. [1 ]
Teufelsbauer, H. [2 ]
Neumayer, C. [2 ]
Domenig, C. [2 ]
Wressnegger, A. [1 ]
Wolf, F. [1 ]
Funovics, M. [1 ]
机构
[1] Med Univ Vienna, Dept Biomed Imaging & Nucl Med, A-1090 Vienna, Austria
[2] Med Univ Vienna, Dept Vasc Surg, A-1090 Vienna, Austria
关键词
Aortic aneurysm; thoracic; Endovascular procedures; Spinal cord ischemia; FENESTRATED ENDOGRAFTS; COMPLICATIONS; MULTICENTER;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim. The aim of this paper was to report our preliminary experience in outcome, safety and mid-term results in the treatment of thoracoabdominal aortic aneurysms (TAAA) with a novel multibranchstentgraft (E-xtra DESIGN ENGINEERING, JOTEC, Germany). Methods. Eight patients (mean age 66 years, 2 female) with TAAA (Crawford type I: 2 cases, type III: 3 cases, type IV: 3 cases), mean aneurysm diameter 61 mm, growth over 5 nun per year were treated. Implantation was performed under general anesthesia and surgical exposition of the common femoral artery. Brachial access was percutaneous in 5/8 patients. Balloon-expandable (Advanta V12) bridging stent-grafts were employed and lined with self-expanding nitinol stents. All patients except type IV TAAA received a spinal drainage catheter. Results. The device was successfully deployed in 8/8 patients. 29/32 visceral branches were engaged. One stenosed celiac trunk was left untreated without further consequences, two renal arteries which could not be cannulated were revascularized with iliorenal bypass. One patient needed surgical revision of groin hematoma, one patient suffered from permanent protopathic sensory deficit. No renal complications occurred. Since the primary implantation was deliberately kept short and amount of contrast agent was minimised, four patients needed a secondary percutaneous procedure (Palmaz stent implantation for type I endoleak, re-PTA or additional bridging stent-graft implantation for type III endoleak). The assisted primary success rate was 8/8. Mean follow-up was 18 months. Success was stable in 7/8 patients, one patient shows type V endoleak with 5mrn sac expansion. No mortality or complication occurred during follow-up. Conclusion. The JOTEC E-xtra DESIGN ENGINEERING multibranch stent-graft is a promising new candidate for endovascular TAAA treatment with sufficient safety and efficacy. Its short delivery time suggests its use in patients with rapid aneurysm growth or high anxiety.
引用
收藏
页码:543 / 550
页数:8
相关论文
共 50 条
  • [1] Combined endovascular stent-graft repair and adjunctive visceral vessel reconstruction for complex thoracoabdominal aortic aneurysms
    Donas, K. P.
    Schulte, S.
    Krause, E.
    Horsch, S.
    INTERNATIONAL ANGIOLOGY, 2007, 26 (03) : 213 - 218
  • [2] Aortic aneurysms' treatment with endovascular stent-graft
    Rahman, Ali
    Colak, Mehmet Cengiz
    Ozdemir, Huseyin
    Ozguler, Murat
    Cil, Barbaros E.
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 17 (03): : 167 - 172
  • [3] A Modified Proximal Stent-Graft for Spinal Cord Preconditioning During Staged Endovascular Repair of Thoracoabdominal Aortic Aneurysms
    Rinaldi, Enrico
    Carta, Niccolo
    Melissano, Germano
    Chiesa, Roberto
    Bertoglio, Luca
    JOURNAL OF ENDOVASCULAR THERAPY, 2020, 27 (05) : 764 - 768
  • [4] Endovascular repair of ruptured abdominal aortic aneurysms with the endurant stent-graft: a combined experience from three centers
    Papazoglou, Konstantinos
    Mallios, Alexandros
    Buster, Bryan
    Antoniadis, Pavlos
    Karkos, Christos
    Staramos, Dimitris
    Dervisis, Konstantinos
    Messiner, Ryan
    Blebea, John
    JOURNAL OF CARDIOVASCULAR SURGERY, 2017, 58 (05) : 643 - 649
  • [5] Stent-Graft Repair of Thoracic Aortic Aneurysms
    Rousseau, H.
    Bolduc, J. P.
    Dambrin, C.
    Marcheix, B.
    Canevet, G.
    Otal, P.
    TECHNIQUES IN VASCULAR AND INTERVENTIONAL RADIOLOGY, 2005, 8 (01) : 61 - 72
  • [6] Stent graft types for endovascular repair of thoracic aortic aneurysms
    Rolph, Rachel
    Duffy, James M. N.
    Waltham, Matthew
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2015, (09):
  • [7] Endovascular Repair of Thoracoabdominal Aortic Aneurysms
    Siegenthaler, Michael P.
    Beyersdorf, Friedhelm
    TEXAS HEART INSTITUTE JOURNAL, 2009, 36 (05) : 446 - 448
  • [8] Early experience with the talent™ stent-graft system for endoluminal repair of abdominal aortic aneurysms
    Criado, FJ
    Wilson, EP
    Wellons, E
    Abul-Khoudoud, O
    Gnanasekeram, H
    TEXAS HEART INSTITUTE JOURNAL, 2000, 27 (02) : 128 - 135
  • [9] Repair of abdominal aortic aneurysms with the Excluder® bifurcated stent-graft
    Pfammatter, T
    Mayer, D
    Pfiffner, R
    Koehler, C
    Hechelhammer, L
    Lachat, ML
    JOURNAL OF CARDIOVASCULAR SURGERY, 2003, 44 (04) : 549 - 552
  • [10] The choice of stent-graft for endovascular repair of abdominal aortic aneurysm
    Chuter, TAM
    JOURNAL OF CARDIOVASCULAR SURGERY, 2003, 44 (04) : 519 - 525