A flow system with in-line blank correction applied to the spectrophotometric determination of total iron and chromium (VI) in wastewaters

被引:6
|
作者
Morais, IPA
Souto, MRS
Rangel, AOSS
机构
[1] Univ Catolica Portuguesa, Escuela Super Biotecnol, P-4200072 Porto, Portugal
[2] Univ Fernando Pessoa, P-4249004 Porto, Portugal
关键词
flow system; total iron; chromium (VI); blank correction; wastewaters;
D O I
10.1007/s00216-002-1291-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A flow system using the sample as the carrier with a propulsion device located after the detector is presented. This approach allows the correction of the intrinsic color of the sample, as it provides baseline adjustment for each sample. A confluence situated just after the selection valve allows the sample composition to be adjusted for the colorimetric measurement. The developed methodology was applied to the colorimetric determination of total Fe and Cr (VI) in wastewaters at 0.1-6.0 mg L-1 and 0.03-1.0 mg L-1, respectively. RSDs lower than 3% and a sampling rate of approximately 40 h(-1) were obtained.
引用
收藏
页码:119 / 122
页数:4
相关论文
共 17 条
  • [1] Rapid determination of chromium(VI) in electroplating waste water by use of a spectrophotometric flow injection system
    Yuan, Dong
    Fu, Dayou
    Wang, Rong
    Yuan, Jigang
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2008, 71 (01) : 276 - 279
  • [2] Automated Spectrophotometric Multi-Pumping Flow System for the Determination of Total Iron in Wine
    Andreu, Cristina
    Danchana, Kaewta
    Cerda, Victor
    ANALYTICAL LETTERS, 2020, 53 (17) : 2775 - 2783
  • [3] FLOW-INJECTION DETERMINATION OF CHROMIUM(VI) BASED ON REDOX REACTIONS OF CHROMIUM(VI) WITH IRON(II) AND COPPER(II) WITH IRON(II) IN THE PRESENCE OF DIPHOSPHATE AND NEOCUPROINE
    ITABASHI, H
    TESHIMA, N
    KAWASHIMA, T
    ANALYTICAL SCIENCES, 1995, 11 (04) : 693 - 694
  • [4] On-line spectrophotometric determination of ferrous and total iron in monominerals by flow injection combined with a Schlenk line-based digestion apparatus to exclude oxygen
    Xue, Ding-Shuai
    Chen, Guo-Ju
    Su, Ben-Xun
    Liu, Yan-Hong
    Zhang, Dan-Ping
    Guo, Qian
    Guo, Ju-Jie
    Sun, Jie-Fang
    MICROCHEMICAL JOURNAL, 2020, 155
  • [5] Spectrophotometric determination of total proteins by derivatization with p-benzoquinone in a flow system
    Lichtig, J
    Guarilha, O
    Oliveira, RMS
    Masini, JC
    Trujillo, LM
    ANALYTICAL LETTERS, 2001, 34 (02) : 193 - 200
  • [6] Multi-syringe flow injection system with in-line microwave digestion for the determination of phosphorus
    Almeida, MIGS
    Segundo, MA
    Lima, JLFC
    Rangel, AOSS
    TALANTA, 2004, 64 (05) : 1283 - 1289
  • [7] Determination of chromium (III) and chromium (VI) in water using flow injection on-line preconcentration and separation with flame absorption spectrometric detection
    Kang, WJ
    Liang, SX
    Ha, J
    Shen, SG
    Sun, HW
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2003, 23 (03) : 572 - 575
  • [8] On-line microwave slurry sample digestion using flow systems for the spectrophotometric determination of iron in seafood
    Pereira, ER
    Rohwedder, JJR
    Arruda, MAZ
    ANALYST, 1998, 123 (05) : 1023 - 1028
  • [9] Application of portable electrokinetic flow analysis system for determination of chromium(VI) and cadmium (II) in mineral water
    Yang, L
    He, YZ
    Gan, W
    Deng, N
    Li, M
    Lin, XQ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 29 (05) : 555 - 557
  • [10] Sensitive determination of chromium (VI) in paint samples using a membrane optode coupled to a multisyringe flow injection system
    Castilleja-Rivera, W. L.
    Hinojosa-Reyes, L.
    Guzman-Mar, J. L.
    Hernandez-Ramirez, A.
    Ruiz-Ruiz, E.
    Cerda, V.
    TALANTA, 2012, 99 : 730 - 736