Terahertz-dependent evaluation of water content in high-water-cut crude oil using additive-manufactured samplers

被引:8
作者
Guan, LiMei [1 ]
Zhan, HongLei [1 ]
Miao, XinYang [1 ]
Zhu, Jing [1 ]
Zhao, Kun [1 ]
机构
[1] China Univ Petr, Beijing Key Lab Opt Detect Technol Oil & Gas, Beijing 102249, Peoples R China
关键词
water content; crude oil; additive manufacturing; terahertz spectroscopy; TIME-DOMAIN SPECTROSCOPY; NUMERICAL-SIMULATION; DYNAMICS; PAPER; ROCK;
D O I
10.1007/s11433-016-0491-3
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The evaluation of water content in crude oil is of significance to petroleum exploration and transportation. Terahertz ( THz) waves are sensitive to fluctuations in the dipole moment of water. However, due to the strong absorption of water in the THz range, it is difficult for the THz spectrum to determine high water content with the common sampler. In this research, micron- grade samplers for THz detection were designed and manufactured using additive manufacturing ( AM) technology. Oil- water mixtures with water content from 1.8% to 90.6% were measured with the THz- TDS system using sample cells. In addition, a detailed analysis was performed of the relationships among THz parameters such as signal peak, time delay, and refractive index as well as absorption coefficient and high water content (> 60%). Results suggest that the combination of THz spectroscopy and AM technique is effective for water content evaluation in crude oil and can be further applied in the petroleum industry.
引用
收藏
页数:5
相关论文
共 34 条
[21]  
Onses MS, 2013, NAT NANOTECHNOL, V8, P667, DOI [10.1038/nnano.2013.160, 10.1038/NNANO.2013.160]
[22]   Nanoscale Three-Dimensional Patterning of Molecular Resists by Scanning Probes [J].
Pires, David ;
Hedrick, James L. ;
De Silva, Anuja ;
Frommer, Jane ;
Gotsmann, Bernd ;
Wolf, Heiko ;
Despont, Michel ;
Duerig, Urs ;
Knoll, Armin W. .
SCIENCE, 2010, 328 (5979) :732-735
[23]  
Shangguan Y. N., 2015, Petroleum, V1, P300, DOI [10.1016/j.petlm.2015.10.010, DOI 10.1016/J.PETLM.2015.10.010]
[24]   THz ATR Spectroscopy for Inline Monitoring of Highly Absorbing Liquids [J].
Soltani, Amin ;
Busch, Stefan F. ;
Plew, Patrick ;
Balzer, Jan C. ;
Koch, Martin .
JOURNAL OF INFRARED MILLIMETER AND TERAHERTZ WAVES, 2016, 37 (10) :1001-1006
[25]   Simultaneous Characterization of Water Content and Distribution in High-Water-Cut Crude Oil [J].
Song, Yan ;
Zhan, Hong L. ;
Zhao, Kun ;
Miao, Xin Y. ;
Lu, Zhi Q. ;
Bao, Ri M. ;
Zhu, Jing ;
Xiao, Li Z. .
ENERGY & FUELS, 2016, 30 (05) :3929-3933
[26]   3D Printing of Interdigitated Li-Ion Microbattery Architectures [J].
Sun, Ke ;
Wei, Teng-Sing ;
Ahn, Bok Yeop ;
Seo, Jung Yoon ;
Dillon, Shen J. ;
Lewis, Jennifer A. .
ADVANCED MATERIALS, 2013, 25 (33) :4539-4543
[27]   Do Hydration Dynamics Follow the Structural Perturbation during Thermal Denaturation of a Protein: A Terahertz Absorption Study [J].
Trung Quan Luong ;
Verma, Pramod Kumar ;
Mitra, Rajib Kumar ;
Havenith, Martina .
BIOPHYSICAL JOURNAL, 2011, 101 (04) :925-933
[28]   A mm-Wave Sensor for Remote Measurement of Moisture in Thin Paper Layers [J].
Vassilev, Vessen ;
Stoew, Borys ;
Blomgren, Jakob ;
Andersson, Gert .
IEEE TRANSACTIONS ON TERAHERTZ SCIENCE AND TECHNOLOGY, 2015, 5 (05) :770-778
[29]   Ultrabroadband THz Time-Domain Spectroscopy of a Free-Flowing Water Film [J].
Wang, Tianwu ;
Klarskov, Pernille ;
Jepsen, Peter Uhd .
IEEE TRANSACTIONS ON TERAHERTZ SCIENCE AND TECHNOLOGY, 2014, 4 (04) :425-431
[30]   Application of laser measuring, numerical simulation and rapid prototyping to titanium dental castings [J].
Wu, M ;
Tinschert, J ;
Augthun, M ;
Wagner, I ;
Schädlich-Stubenrauch, J ;
Sahm, PR ;
Spiekelmann, H .