In silico modeling of bone adaptation to rest-inserted loading: Strain energy density versus fluid flow as stimulus

被引:16
作者
Tiwari, Abhishek Kumar [1 ]
Kumar, Rakesh [1 ]
Tripathi, Dharmendra [1 ]
Badhyal, Subham [2 ]
机构
[1] Manipal Univ Jaipur, Dept Mech Engn, Room 12,Fac Block 1,Near GVK Toll Plaza, Jaipur 303007, Rajasthan, India
[2] Indian Inst Technol Ropar, Dept Mech Engn, Roopnagar 140001, Punjab, India
关键词
Bone adaptation; Strain energy density; Canalicular fluid flow; Osteogenesis; Aging; LACUNAR-CANALICULAR SYSTEM; MECHANICALLY LOADED BONE; FINITE-ELEMENT-ANALYSIS; CORTICAL BONE; OSTEOGENIC RESPONSE; SOLUTE TRANSPORT; LOW-MAGNITUDE; LONG-BONE; VIVO; AGE;
D O I
10.1016/j.jtbi.2018.03.009
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
In vivo studies suggest that cyclic and low-magnitude loading can be useful over pharmaceutical drugs in normalizing bone loss as it encourages osteogenesis (i.e. new bone formation) at the sites of elevated strain magnitude. In silico models assumed normal strain or strain energy density (SED) as the stimulus to predict loading-induced osteogenesis, however, these models may have limited success in fitting the in vivo new bone formation at several instances. For example, rest-inserted cyclic loading amplifies the new bone formation as compared to continuous-cyclic loading even though similar strain magnitude were induced in both the cases. It is also believed that loading-induced interstitial fluid flow can also be a potential stimulus of osteogenesis. The present study hypothesizes that fluid motion as osteogenic stimulus may explain the afore-mentioned anomalies. Accordingly, this work studies osteogenesis as functions of SED and canalicular fluid motion using an in silico model. Therefore, the new bone formation is considered roughly proportional to stimuli above their osteogenic thresholds. This model attempts to simulate in vivo new bone formation noticed in rest-inserted cantilever loading studies. The model's prediction of site-specific new bone formation improves when fluid flow is considered as the stimulus. It is also noticed that fluid motion as the stimulus closely fits the new bone formation for another in vivo study where the effects of aging on osteogenesis were examined. These attempts to establish fluid flow as a potential osteogenic stimulus can be useful in the prediction of site-specific new bone formation. The findings will ultimately be useful in designing biomechanical interventions such as prophylactic exercises to cure bone loss. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:110 / 127
页数:18
相关论文
共 73 条
  • [1] Nitric oxide production by bone cells is fluid shear stress rate dependent
    Bacabac, RG
    Smit, TH
    Mullender, MG
    Dijcks, SJ
    Van Loon, JJWA
    Klein-Nulend, J
    [J]. BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2004, 315 (04) : 823 - 829
  • [2] AN APPROACH FOR TIME-DEPENDENT BONE MODELING AND REMODELING - APPLICATION - A PRELIMINARY REMODELING SIMULATION
    BEAUPRE, GS
    ORR, TE
    CARTER, DR
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1990, 8 (05) : 662 - 670
  • [3] Bergh MS, 2004, VET SURG, V33, P238, DOI 10.1111/j.1532-950X.2004.04035.x
  • [4] THEORY OF ELASTICITY AND CONSOLIDATION FOR A POROUS ANISOTROPIC SOLID
    BIOT, MA
    [J]. JOURNAL OF APPLIED PHYSICS, 1955, 26 (02) : 182 - 185
  • [5] General theory of three-dimensional consolidation
    Biot, MA
    [J]. JOURNAL OF APPLIED PHYSICS, 1941, 12 (02) : 155 - 164
  • [6] The Periosteal Bone Surface is Less Mechano-Responsive than the Endocortical
    Birkhold, Annette I.
    Razi, Hajar
    Duda, Georg N.
    Weinkamer, Richard
    Checa, Sara
    Willie, Bettina M.
    [J]. SCIENTIFIC REPORTS, 2016, 6
  • [7] Mineralizing surface is the main target of mechanical stimulation independent of age: 3D dynamic in vivo morphometry
    Birkhold, Annette I.
    Razi, Hajar
    Duda, Georg N.
    Weinkamer, Richard
    Checa, Sara
    Willie, Bettina M.
    [J]. BONE, 2014, 66 : 15 - 25
  • [8] Burger E.H., 1998, ADV ORG BIO A-C, V5, P123
  • [9] Bone poroelasticity
    Cowin, SC
    [J]. JOURNAL OF BIOMECHANICS, 1999, 32 (03) : 217 - 238
  • [10] FUNCTIONAL ADAPTATION IN LONG BONES - ESTABLISHING INVIVO VALUES FOR SURFACE REMODELING RATE COEFFICIENTS
    COWIN, SC
    HART, RT
    BALSER, JR
    KOHN, DH
    [J]. JOURNAL OF BIOMECHANICS, 1985, 18 (09) : 665 - +