Estimation of k-Space Trajectories in Spiral MRI

被引:74
作者
Tan, Hao
Meyer, Craig H. [1 ,2 ]
机构
[1] Univ Virginia, Dept Radiol, Charlottesville, VA 22908 USA
[2] Univ Virginia, Dept Biomed Engn, Charlottesville, VA 22908 USA
基金
美国国家卫生研究院;
关键词
MRI; spiral imaging; eddy currents; k-space trajectory; PULSES; ERRORS;
D O I
10.1002/mrm.21813
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
For non-Cartesian data acquisition in MRI, k-space trajectory infidelity due to eddy current effects and other hardware imperfections will blur and distort the reconstructed images. Even with the shielded gradients and eddy current compensation techniques of current scanners, the deviation between the actual k-space trajectory and the requested trajectory remains a major reason for image artifacts in non-Cartesian MRI. It Is often not practical to measure the k-space trajectory for each imaging slice. It has been reported that better image quality is achieved in radial scanning by correcting anisotropic delays on different physical gradient axes. In this article the delay model is applied in spiral k-space trajectory estimation to reduce image artifacts. Then a novel estimation method combining the anisotropic delay model and a simple convolution eddy current model further reduces the artifact level in spiral image reconstruction. The root mean square error and peak error in both phantom and in vivo images reconstructed using the estimated trajectories are reduced substantially compared to the results achieved by only tuning delays. After a one-time calibration, it is thus possible to get an accurate estimate of the spiral trajectory and a high-quality image reconstruction for an arbitrary scan plane. Magn Reson Med 61:1396-1404, 2009. (C) 2009 Wiley-Liss, Inc.
引用
收藏
页码:1396 / 1404
页数:9
相关论文
共 21 条
[1]   Effects of gradient anisotropy in MRI [J].
Aldefeld, B ;
Börnert, P .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (04) :606-614
[2]   Gradient characterization using a Fourier-transform technique [J].
Alley, MT ;
Glover, GH ;
Pelc, NJ .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (04) :581-587
[3]  
Barmet C., 2005, Proceedings of the International Society for Magnetic Resonance in Medicine, P681
[4]   Improved k-space trajectory measurement with signal shifting [J].
Beaumont, Marine ;
Lamalle, Laurent ;
Segebarth, Christoph ;
Barbier, Emmanuel L. .
MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (01) :200-205
[5]  
Bernstein M.A., 2004, HDB MRI PULSE SEQUEN, P319
[6]  
Börnert P, 1999, MAGN RESON MATER PHY, V9, P29
[7]   Calibration of gradient propagation delays for accurate two-dimensional radiofrequency pulses [J].
Davies, NP ;
Jezzard, P .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (01) :231-236
[8]  
De Zanche N., 2006, P 14 ANN M ISMRM, P781
[9]   Improvement of spiral MRI with the measured k-space trajectory [J].
Ding, XP ;
Tkach, J ;
Ruggieri, P ;
Perl, J ;
Masaryk, T .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (05) :938-940
[10]   Simple correction method for k-space trajectory deviations in MRI [J].
Duyn, JH ;
Yang, YH ;
Frank, JA ;
van der Veen, JW .
JOURNAL OF MAGNETIC RESONANCE, 1998, 132 (01) :150-153