Comparison of Hemodynamics After Aortic Root Replacement Using Valve-Sparing or Bioprosthetic Valved Conduit

被引:35
|
作者
Collins, Jeremy D.
Semaan, Edouard
Barker, Alex
McCarthy, Patrick M.
Carr, James C.
Markl, Michael
Malaisrie, S. Chris
机构
[1] Northwestern Univ, Dept Radiol, Feinberg Sch Med, Chicago, IL 60611 USA
[2] Northwestern Univ, Div Cardiac Surg, Feinberg Sch Med, Chicago, IL 60611 USA
[3] Northwestern Univ, McCormick Sch Engn, Dept Biomed Engn, Chicago, IL 60611 USA
关键词
PHASE-CONTRAST MRI; MAGNETIC-RESONANCE; FLOW PATTERNS; ASCENDING AORTA; MARFAN-SYNDROME; BLOOD-FLOW; SURGERY; GRAFT; ANEURYSM; ENERGY;
D O I
10.1016/j.athoracsur.2015.04.109
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The purpose of this study is to compare aortic hemodynamics and blood flow patterns using in-vivo four-dimensional (4D) flow magnetic resonance imaging (MRI) in patients after valve-sparing aortic root replacement (VSARR) and aortic root replacement with bioprosthetic valves (BIO-ARR). Methods. In-vivo 4D flow MRI was performed in 11 patients after VSARR (47 +/- 18 years, 6 bicuspid aortic valves, 5 trileaflet aortic valves), 16 patients after BIO-ARR (52 +/- 14 years), and 10 healthy controls (47 +/- 16 years). Analysis included three-dimensional blood flow visualization and grading of helix flow in the ascending aorta (AAo) and arch. Peak systolic velocity was quantified in 9 analysis planes in the AAo, aortic arch, and descending aorta. Flow profile uniformity was evaluated in the aortic root and ascending aorta. Results. Peak systolic velocity (2.0 to 2.5m/second) in the aortic root and AAo in both VSARR and BIO-ARR were elevated compared with controls (1.1 to 1.3m/second, p < 0.005). Flow asymmetry in BIO-ARR was increased compared with VSARR, evidenced by more AAo outflow jets (9 of 16 BIO-ARR, 0 of 11 in VSARR). The BIO- ARR exhibited significantly (p < 0.001) increased helix flow in the AAo as a measure of increased flow derangement. Finally, peak systolic velocities were elevated at the aortic root for BIO-ARR (2.5 vs 2.0m/second, p < 0.05) but lower in the distal AAo when compared with VSARR. Conclusions. The VSARR results in improved hemodynamic outcomes when compared with BIO- ARR, as indicated by reduced peak velocities in the aortic root and less helix flow in the AAo by 4D flow MRI. Longitudinal research assessing the clinical impact of these differences in hemodynamic outcomes is warranted. (C) 2015 by The Society of Thoracic Surgeons
引用
收藏
页码:1556 / 1562
页数:7
相关论文
共 50 条
  • [1] Biological solutions to aortic root replacement: valve-sparing versus bioprosthetic conduit
    Gaudino, Mario
    Di Franco, Antonino
    Ohmes, Lucas B.
    Weltert, Luca
    Lau, Christopher
    Gambardella, Ivancarmine
    Salica, Andrea
    Munjal, Monica
    Elsayed, Mohamed
    Girardi, Leonard N.
    De Paulis, Ruggero
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2017, 24 (06) : 855 - 861
  • [2] Comparison of David V valve-sparing root replacement and bioprosthetic valve conduit for aortic root aneurysm
    DeNino, Walter F.
    Toole, John Matthew
    Rowley, Christopher
    Stroud, Martha R.
    Ikonomidis, John S.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 148 (06) : 2883 - 2887
  • [3] Valve-sparing Aortic Root Replacement
    Shimizu, Hideyuki
    Yozu, Ryohei
    ANNALS OF THORACIC AND CARDIOVASCULAR SURGERY, 2011, 17 (04) : 330 - 336
  • [4] Aortic valve-sparing root replacement or Bentall?
    Iannacone, Erin M.
    Lau, Christopher
    Soletti, Giovanni, Jr.
    Olaria, Roberto Perezgrovas
    Harik, Lamia
    Dimagli, Arnaldo
    Girardi, Leonard N.
    ANNALS OF CARDIOTHORACIC SURGERY, 2023, 12 (03) : 168 - 178
  • [5] Valve-sparing aortic root replacement
    Koolbergen, David R.
    Manshanden, Johan S. J.
    Bouma, Berto J.
    Blom, Nico A.
    Mulder, Barbara J. M.
    de Mol, Bas A. J. M.
    Hazekamp, Mark G.
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2015, 47 (02) : 348 - 354
  • [6] Clinical Outcomes of the David V Valve-Sparing Root Replacement Compared With Bioprosthetic Valve-Conduits for Aortic Root Aneurysms
    Esaki, Jiro
    Leshnower, Bradley G.
    Binongo, Jose N.
    Lasanajak, Yi
    McPherson, LaRonica
    Halkos, Michael E.
    Guyton, Robert A.
    Chen, Edward P.
    ANNALS OF THORACIC SURGERY, 2017, 103 (06) : 1824 - 1832
  • [7] Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
    Tavakoli, Reza
    Lebreton, Guillaume
    Gassmann, Max
    Jamshidi, Peiman
    Leprince, Pascal
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2017, (130):
  • [8] Valve-Sparing Aortic Root Replacement for Patients with a Fontan Circulation
    Erez, Eldad
    Tam, Vincent K. H.
    Galliani, Carlos
    Lashus, Andrew
    Doublin, Nancy A.
    Peretti, Jana
    JOURNAL OF HEART VALVE DISEASE, 2012, 21 (02) : 175 - 180
  • [9] Proposed Modification for Valve-Sparing Aortic Root Replacement
    Mahesh, Balakrishnan
    Deville, Claude
    Nashef, Samer
    ANNALS OF THORACIC SURGERY, 2014, 97 (05) : 1811 - 1813
  • [10] The 10 Commandments for Valve-Sparing Aortic Root Replacement
    Samman, Bana
    Mazine, Amine
    Ouzounian, Maral
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2024,