Vascular Response to Drug-Eluting Stent With Biodegradable vs. Durable Polymer - Optical Coherence Tomography Substudy of the NEXT

被引:38
作者
Kubo, Takashi [1 ]
Akasaka, Takashi [1 ]
Kozuma, Ken [2 ]
Kimura, Kazuo [3 ]
Fusazaki, Tetsuya [4 ]
Okura, Hiroyuki [5 ]
Shinke, Toshiro [6 ]
Ino, Yasushi [1 ]
Hasegawa, Takao [7 ]
Takashima, Hiroaki [8 ]
Takamisawa, Itaru [9 ]
Yamaguchi, Hiroshi [10 ]
Igarashi, Keiichi [11 ]
Kadota, Kazushige [12 ]
Tanabe, Kengo [13 ]
Nakagawa, Yoshihisa [14 ]
Muramatsu, Toshiya [15 ]
Morino, Yoshihiro [4 ]
Kimura, Takeshi [16 ]
机构
[1] Wakayama Med Univ, Dept Cardiovasc Med, Wakayama 6418510, Japan
[2] Teikyo Univ Hosp, Div Cardiol, Tokyo, Japan
[3] Yokohama City Univ, Div Cardiol, Med Ctr, Yokohama, Kanagawa 232, Japan
[4] Iwate Med Univ, Div Cardiol, Morioka, Iwate 020, Japan
[5] Kawasaki Med Sch, Div Cardiol, Kurashiki, Okayama, Japan
[6] Kobe Univ, Grad Sch Med, Div Cardiovasc Med, Kobe, Hyogo 657, Japan
[7] Osaka City Univ Hosp, Div Cardiovasc Med, Osaka, Japan
[8] Aichi Med Univ Hosp, Dept Cardiol, Nagakute, Aichi, Japan
[9] Sakakibara Mem Hosp, Div Cardiol, Tokyo, Japan
[10] Tenyoukai Cent Hosp, Div Cardiol, Kagoshima, Japan
[11] Hokkaido Social Insurance Hosp, Div Cardiol, Sapporo, Hokkaido, Japan
[12] Kurashiki Cent Hosp, Div Cardiol, Kurashiki, Okayama, Japan
[13] Mitsui Mem Hosp, Div Cardiol, Tokyo 101, Japan
[14] Tenri Hosp, Div Cardiol, Tenri, Nara 632, Japan
[15] Saiseikai Yokohamashi Tobu Hosp, Div Cardiol, Yokohama, Kanagawa, Japan
[16] Kyoto Univ, Grad Sch Med, Dept Cardiovasc Med, Kyoto, Japan
关键词
Drug-eluting stent; Optical coherence tomography; Percutaneous coronary intervention; CORONARY-ARTERY; FOLLOW-UP; EVEROLIMUS; THROMBOSIS; OUTCOMES; LEADERS;
D O I
10.1253/circj.CJ-14-0337
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The aim of the present study was to compare vascular healing response between everolimus-eluting stent (EES) and biolimus-eluting stent (BES) using optical coherence tomography (OCT). Methods and Results: In the NOBORI Biolimus-Eluting Versus XIENCE V/PROMUS Everolimus-Eluting Stent Trial (NEXT), a formal OCT substudy investigated 91 patients (55 EES-treated lesions in 48 patients and 51 BES-treated lesions in 43 patients) with 8-12 months follow-up imaging at 18 centers. A total of 980 frames with 8,996 struts in EES and 907 frames with 8,745 struts in BES were analyzed. Mean neointima thickness in EES and BES was 105 +/- 82 mu m and 91 +/- 80 mu m, respectively (P<0.001). With regard to stent-treated lesions, the percentage of struts not covered by neointima (3 +/- 7% vs. 9 +/- 10%, P<0.001) and the frequency of stent-treated lesions with any uncovered struts (n=28, 51% vs. n=42, 82%; P<0.001) were significantly lower in EES compared with BES. In addition, the percentage of malapposed struts (0.2 +/- 0.8% vs. 1.3 +/- 2.8%, P=0.006) and the frequency of stent-treated lesions with any malapposed struts (n=6, 11% vs. n=14, 27%; P=0.028) were significantly lower in EES compared with BES. Conclusions: Incomplete vascular healing characterized by the presence of struts not covered by neointima and malapposed struts was less common in EES compared with BES.
引用
收藏
页码:2408 / 2414
页数:7
相关论文
共 20 条
[1]   An optical coherence tomography study of a biodegradable vs. durable polymer-coated limus-eluting stent: a LEADERS trial sub-study [J].
Barlis, Peter ;
Regar, Evelyn ;
Serruys, Patrick W. ;
Dimopoulos, Konstantinos ;
van der Giessen, Willem J. ;
van Geuns, Robert-Jan M. ;
Ferrante, Giuseppe ;
Wandel, Simon ;
Windecker, Stephan ;
van Es, Gerrit-Anne ;
Eerdmans, Pedro ;
Jueni, Peter ;
di Mario, Carlo .
EUROPEAN HEART JOURNAL, 2010, 31 (02) :165-176
[2]   Biodegradable Polymer Versus Permanent Polymer Drug-Eluting Stents and Everolimus- Versus Sirolimus-Eluting Stents in Patients With Coronary Artery Disease 3-Year Outcomes From a Randomized Clinical Trial [J].
Byrne, Robert A. ;
Kastrati, Adnan ;
Massberg, Steffen ;
Wieczorek, Anna ;
Laugwitz, Karl-Ludwig ;
Hadamitzky, Martin ;
Schulz, Stefanie ;
Pache, Juergen ;
Fusaro, Massimiliano ;
Hausleiter, Joerg ;
Schoemig, Albert ;
Mehilli, Julinda .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (13) :1325-1331
[3]   Favorable neointimal coverage in everolimus-eluting stent at 9 months after stent implantation: comparison with sirolimus-eluting stent using optical coherence tomography [J].
Choi, Hyun Hee ;
Kim, Jung-Sun ;
Yoon, Duck Hyoung ;
Hong, Kyung-Soon ;
Kim, Tae Hoon ;
Kim, Byeong Keuk ;
Ko, Young-Guk ;
Choi, Donghoon ;
Jang, Yangsoo ;
Hong, Myeong-Ki .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (03) :491-497
[4]   Pathological correlates of late drug-eluting stent thrombosis - Strut coverage as a marker of endothelialization [J].
Finn, Aloke V. ;
Joner, Michael ;
Nakazawa, Gaku ;
Kolodgie, Frank ;
Newell, John ;
John, Mike C. ;
Gold, Herman K. ;
Virmani, Renu .
CIRCULATION, 2007, 115 (18) :2435-2441
[5]   Examination of the In Vivo Mechanisms of Late Drug-Eluting Stent Thrombosis Findings From Optical Coherence Tomography and Intravascular Ultrasound Imaging [J].
Guagliumi, Giulio ;
Sirbu, Vasile ;
Musumeci, Giuseppe ;
Gerber, Robert ;
Biondi-Zoccai, Giuseppe ;
Ikejima, Hideyuki ;
Ladich, Elena ;
Lortkipanidze, Nikoloz ;
Matiashvili, Aleksandre ;
Valsecchi, Orazio ;
Virmani, Renu ;
Stone, Gregg W. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (01) :12-20
[6]   Endothelial cell recovery between comparator polymer-based drug-eluting stents [J].
Joner, Michael ;
Nakazawa, Gaku ;
Finn, Aloke V. ;
Quee, Shawn Chin ;
Coleman, Leslie ;
Acampado, Eduardo ;
Wilson, Patricia S. ;
Skorija, Kristi ;
Cheng, Qi ;
Xu, Xin ;
Gold, Herman K. ;
Kolodgie, Frank D. ;
Virmani, Renu .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (05) :333-342
[7]   Comparison of Everolimus-Eluting and Sirolimus-Eluting Coronary Stents 1-Year Outcomes from the Randomized Evaluation of Sirolimus-Eluting Versus Everolimus-Eluting Stent Trial (RESET) [J].
Kimura, Takeshi ;
Morimoto, Takeshi ;
Natsuaki, Masahiro ;
Shiomi, Hiroki ;
Igarashi, Keiichi ;
Kadota, Kazushige ;
Tanabe, Kengo ;
Morino, Yoshihiro ;
Akasaka, Takashi ;
Takatsu, Yoshiki ;
Nishikawa, Hideo ;
Yamamoto, Yoshito ;
Nakagawa, Yoshihisa ;
Hayashi, Yasuhiko ;
Iwabuchi, Masashi ;
Umeda, Hisashi ;
Kawai, Kazuya ;
Okada, Hisayuki ;
Kimura, Kazuo ;
Simonton, Charles A. ;
Kozuma, Ken .
CIRCULATION, 2012, 126 (10) :1225-+
[8]   Effect of strut thickness on neointimal atherosclerotic change over an extended follow-up period (≥4 years) after bare-metal stent implantation: Intracoronary optical coherence tomography examination [J].
Kitabata, Hironori ;
Kubo, Takashi ;
Komukai, Kenichi ;
Ishibashi, Kohei ;
Tanimoto, Takashi ;
Ino, Yasushi ;
Takarada, Shigeho ;
Ozaki, Yuichi ;
Kashiwagi, Manabu ;
Orii, Makoto ;
Shiono, Masatsugu ;
Shimamura, Kunihiro ;
Hirata, Kumiko ;
Tanaka, Atsushi ;
Kimura, Keizo ;
Mizukoshi, Masato ;
Imanishi, Toshio ;
Akasaka, Takashi .
AMERICAN HEART JOURNAL, 2012, 163 (04) :608-616
[9]   OCT Compared With IVUS in a Coronary Lesion Assessment The OPUS-CLASS Study [J].
Kubo, Takashi ;
Akasaka, Takashi ;
Shite, Junya ;
Suzuki, Takahiko ;
Uemura, Shiro ;
Yu, Bo ;
Kozuma, Ken ;
Kitabata, Hironori ;
Shinke, Toshiro ;
Habara, Maoto ;
Saito, Yoshihiko ;
Hou, Jingbo ;
Suzuki, Nobuaki ;
Zhang, Shaosong .
JACC-CARDIOVASCULAR IMAGING, 2013, 6 (10) :1095-1104
[10]   Application of Optical Coherence Tomography in Percutaneous Coronary Intervention [J].
Kubo, Takashi ;
Tanaka, Atsushi ;
Kitabata, Hironori ;
Ino, Yasushi ;
Tanimoto, Takashi ;
Akasaka, Takashi .
CIRCULATION JOURNAL, 2012, 76 (09) :2076-2083