"Torsional tapping" atomic force microscopy using T-shaped cantilevers

被引:13
作者
Mullin, Nic [1 ]
Vasilev, Cvetelin [2 ]
Tucker, Jaimey D. [2 ]
Hunter, C. Neil [2 ]
Weber, Christa H. M. [3 ]
Hobbs, Jamie K. [1 ,3 ]
机构
[1] Univ Sheffield, Dept Phys & Astron, Sheffield S3 7RH, S Yorkshire, England
[2] Univ Sheffield, Dept Mol Biol & Biotechnol, Sheffield S10 2TN, S Yorkshire, England
[3] Univ Sheffield, Dept Chem, Sheffield S3 7HF, S Yorkshire, England
关键词
atomic force microscopy; cantilevers; Q-factor; SPEED; AFM;
D O I
10.1063/1.3126047
中图分类号
O59 [应用物理学];
学科分类号
摘要
Torsional oscillation of atomic force microscope cantilevers has been shown to offer increased optical lever sensitivity, quality factor, resonant frequency, and stiffness as compared to flexural oscillation. In this letter, T-shaped cantilevers are oscillated torsionally to give a tapping motion at the tip. This gives many of the advantages of small cantilevers, without the requirement for specialized detection optics. In order to demonstrate the capability of this technique, high resolution images of LH2 membrane protein crystal structures are presented. Reduced settle time and tip-sample force under error signal are also demonstrated.
引用
收藏
页数:3
相关论文
共 50 条
  • [21] Fourier transformed atomic force microscopy: tapping mode atomic force microscopy beyond the Hookian approximation
    Stark, RW
    Heckl, WM
    SURFACE SCIENCE, 2000, 457 (1-2) : 219 - 228
  • [22] Thermally actuated tapping mode atomic force microscopy with polymer microcantilevers
    Mitra, Bhaskar
    Gaitas, Angelo
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2009, 80 (02)
  • [23] Robustness of attractors in tapping mode atomic force microscopy
    Chandrashekar, Abhilash
    Belardinelli, Pierpaolo
    Staufer, Urs
    Alijani, Farbod
    NONLINEAR DYNAMICS, 2019, 97 (02) : 1137 - 1158
  • [24] Enhancing tapping mode atomic force microscopy using AutoResonance control and a hybrid dynamic model
    Baruch, Eyal
    Bucher, Izhak
    MEASUREMENT, 2025, 242
  • [25] Robustness of attractors in tapping mode atomic force microscopy
    Abhilash Chandrashekar
    Pierpaolo Belardinelli
    Urs Staufer
    Farbod Alijani
    Nonlinear Dynamics, 2019, 97 : 1137 - 1158
  • [26] Tapping atomic force microscopy imaging at phase resonance
    Sun, Baishun
    Xie, Chenchen
    Qu, Kaige
    Cao, Liang
    Yan, Jin
    Wang, Ying
    Tian, Liguo
    Zhang, Wenxiao
    Wang, Zuobin
    2021 IEEE INTERNATIONAL CONFERENCE ON MANIPULATION, MANUFACTURING AND MEASUREMENT ON THE NANOSCALE (3M-NANO), 2021, : 47 - 50
  • [27] Double-hole cantilevers for harmonic atomic force microscopy
    Zhang, Weijie
    Chen, Yuhang
    Chu, Jiaru
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (10)
  • [28] Tip Pressure on Semicircular Specimens in Tapping Mode Atomic Force Microscopy in Viscous Fluid Environments
    Shih, Hua-Ju
    Dai, Ching-Liang
    Shih, Po-Jen
    SENSORS, 2017, 17 (10)
  • [29] Near-zero contact force atomic force microscopy investigations using active electromagnetic cantilevers
    Swiadkowski, B.
    Majstrzyk, W.
    Kunicki, P.
    Sierakowski, A.
    Gotszalk, T.
    NANOTECHNOLOGY, 2020, 31 (42)
  • [30] The effect of set point ratio and surface Young's modulus on maximum tapping forces in fluid tapping mode atomic force microscopy
    Kumar, Bharath
    Pifer, Phillip M.
    Giovengo, Anthony
    Legleiter, Justin
    JOURNAL OF APPLIED PHYSICS, 2010, 107 (04)