An Improved Analytical Tuning Rule of a Robust PID Controller for Integrating Systems with Time Delay Based on the Multiple Dominant Pole-Placement Method

被引:13
作者
Zhang, Wei [1 ]
Cui, Yue [1 ]
Ding, Xiangxin [1 ]
机构
[1] Univ Shanghai Sci & Technol, Sch Opt Elect & Comp Engn, 516 Jun Gong Rd, Shanghai 200093, Peoples R China
来源
SYMMETRY-BASEL | 2020年 / 12卷 / 09期
基金
美国国家科学基金会;
关键词
multiple dominant pole-placement method; integrating systems; direct synthesis method; maximum sensitivity; continuous stirred tank reactor; DESIGN;
D O I
10.3390/sym12091449
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
An improved analytical tuning rule of a Proportional-Integral-Derivative (PID) controller for integrating systems with time delay is proposed using the direct synthesis method and multiple dominant pole-placement approach. Different from the traditional multiple dominant pole-placement method, the desired characteristic equation is obtained by placing the third-order dominant poles at -1/lambda and placing the second-order non-dominant poles at -5/lambda (lambda is the tuning parameter). According to root locus theory, the third-order dominant poles and the second-order non-dominant poles are nearly symmetrically located at the two sides of the fifth-order dominant poles. This makes the third-order dominant poles closer to the imaginary axis than the fifth-order dominant poles, which means that, possibly, better performances can be achieved. Analytical formulas of a PID controller with a lead-lag filter are derived. Simple tuning rules are also given to achieve the desired robustness, which is measured by the maximum sensitivity (Ms) value. The proposed method can achieve better performances and maintain better performances when there exist parameters' perturbation compared with other methods. Simulations for various integrating processes as well as the nonlinear continuous stirred tank reactor (CSTR) model illustrate the applicability and effectiveness of the proposed method.
引用
收藏
页数:24
相关论文
共 37 条
[1]   Direct synthesis based tuning of the parallel control structure for integrating processes [J].
Ajmeri, Moina ;
Ali, Ahmad .
INTERNATIONAL JOURNAL OF SYSTEMS SCIENCE, 2015, 46 (13) :2461-2473
[2]  
Alfaro V.M., 2012, P CONTR AUT BARC SPA
[3]   Robust Tuning and Performance Analysis of 2DoF PI Controllers for Integrating Controlled Processes [J].
Alfaro, Victor M. ;
Vilanova, Ramon .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2012, 51 (40) :13182-13194
[4]   PID controller tuning for integrating processes [J].
Ali, Ahmad ;
Majhi, Somanath .
ISA TRANSACTIONS, 2010, 49 (01) :70-78
[5]   PID control of integrating systems using Multiple Dominant Poleplacement method [J].
Anil, Ch. ;
Sree, R. Padma .
ASIA-PACIFIC JOURNAL OF CHEMICAL ENGINEERING, 2015, 10 (05) :734-742
[6]   Tuning of PID controllers for integrating systems using direct synthesis method [J].
Anil, Ch. ;
Sree, R. Padma .
ISA TRANSACTIONS, 2015, 57 :211-219
[7]  
Bequette B.W., 2003, PROCESS CONTROL MODE
[8]   Novel tuning rules for PIDC and PID load frequency controllers considering robustness and sensitivity to measurement noise [J].
Boskovic, Marko ;
Sekara, Tomislav B. ;
Rapaic, Milan R. .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2020, 114
[9]   Controlling industrial dead-time systems: When to use a PID or an advanced controller [J].
da Silva, Lucian Ribeiro ;
Costa Flesch, Rodolfo Cesar ;
Normey-Rico, Julio Elias .
ISA TRANSACTIONS, 2020, 99 :339-350
[10]   PID Controller Tuning via Dominant Pole Placement in Comparison with Ziegler-Nichols Tuning [J].
Fiser, Jaromir ;
Zitek, Pavel .
IFAC PAPERSONLINE, 2019, 52 (18) :43-48