Performance of Direct Estradiol Immunoassays with Human Male Serum Samples

被引:65
作者
Handelsman, David J. [1 ]
Newman, Julie D. [2 ]
Jimenez, Mark [1 ]
McLachlan, Robert [3 ]
Sartorius, Gideon [1 ]
Jones, Graham R. D. [4 ]
机构
[1] Univ Sydney, Concord Hosp, ANZAC Res Inst, Sydney, NSW 2006, Australia
[2] Southern Cross Pathol Australia, Clayton, Vic, Australia
[3] Monash Med Ctr, Prince Henrys Inst Med Res, Clayton, Vic 3168, Australia
[4] St Vincents Hosp, Dept Chem Pathol, SydPath, Darlinghurst, NSW 2010, Australia
基金
澳大利亚国家健康与医学研究理事会;
关键词
TANDEM MASS-SPECTROMETRY; SOCIETY POSITION STATEMENT; POSTMENOPAUSAL WOMEN; BREAST-CANCER; DIRECT RADIOIMMUNOASSAYS; TESTOSTERONE; ASSAYS; MEN; LIMITATIONS; ANDROGENS;
D O I
10.1373/clinchem.2013.213363
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
BACKGROUND: Steroid immunoassays originally required solvent extraction, chromatography, and structurally authentic tracers to avoid interference from steroid cross-reactivity and matrix effects. The demand for steroid assays has driven assay simplification, bypassing this triplet of validity criteria to allow use of unextracted serum, which has introduced bias and nonspecificity at low steroid concentrations. We aimed to evaluate the performance of commercial direct estradiol (E-2) immunoassays relative to the reference method of LC-MS and compared serum E-2 measurements from each assay with biomarkers of estrogen action. METHODS: We measured serum E-2 in duplicate using 5 commercial direct immunoassays and LC-MS in a nested cohort of 101 healthy, asymptomatic men > 40 years old from the Healthy Man Study. For each immunoassay, we evaluated the detectability and distribution of serum E-2 measurements, CV, and bias (relative to LC-MS) by Passing-Bablok regression and deviance plots. RESULTS: Three assays detected E2 in all samples, whereas E-2 was detected in only 53% and 72% of samples by 2 other assays. All 5 assays had positive biases, ranging from 6% to 74%, throughout their ranges. CVs were lower with 4 immunoassays than with LC-MS. LC-MS, but none of the direct immunoassays, correlated with serum testosterone and sex steroid-binding globulin. CONCLUSIONS: The positive bias of direct E2 immunoassays throughout their working range reflects the nonspecific effects of steroid cross-reactivity and/or matrix interference arising from the violation of the triplet validity criteria for steroid immunoassay. (C) 2013 American Association for Clinical Chemistry
引用
收藏
页码:510 / 517
页数:8
相关论文
共 40 条
[31]   Limitations of direct estradiol and testosterone immunoassay kits [J].
Stanczyk, FZ ;
Cho, MM ;
Endres, DB ;
Morrison, JL ;
Patel, S ;
Paulson, RJ .
STEROIDS, 2003, 68 (14) :1173-1178
[32]   Stable isotopically labeled internal standards in quantitative bioanalysis using liquid chromatography/mass spectrometry: necessity or not? [J].
Stokvis, E ;
Rosing, H ;
Beijnen, JH .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (03) :401-407
[33]   Development and evaluation of a reference measurement procedure for the determination of estradiol-17β in human serum using isotope-dilution liquid chromatography-tandem mass spectrometry [J].
Tai, SSC ;
Welsh, MJ .
ANALYTICAL CHEMISTRY, 2005, 77 (19) :6359-6363
[34]   Testosterone measured by 10 immunoassays and by isotope-dilution gas chromatography-mass spectrometry in sera from 116 men, women, and children [J].
Taieb, J ;
Mathian, B ;
Millot, F ;
Patricot, MC ;
Mathieu, E ;
Queyrel, N ;
Lacroix, I ;
Somma-Delpero, C ;
Boudou, P .
CLINICAL CHEMISTRY, 2003, 49 (08) :1381-1395
[35]  
Taieb J, 2002, CLIN CHEM, V48, P583
[36]  
THOMAS CMG, 1987, CLIN CHEM, V33, P1946
[37]   Androgens and bone [J].
Vanderschueren, D ;
Vandenput, L ;
Boonen, S ;
Lindberg, MK ;
Bouillon, R ;
Ohlsson, C .
ENDOCRINE REVIEWS, 2004, 25 (03) :389-425
[38]   Standardization of testosterone measurements in humans [J].
Vesper, Hubert W. ;
Botelho, Julianne Cook .
JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 2010, 121 (3-5) :513-519
[39]   Measurement of total serum testosterone in adult men:: Comparison of current laboratory methods versus liquid chromatography-tandem mass spectrometry [J].
Wang, C ;
Catlin, DH ;
Demers, LM ;
Starcevic, B ;
Swerdloff, RS .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2004, 89 (02) :534-543
[40]   Performance characteristics of eight estradiol immunoassays [J].
Yang, DT ;
Owen, WE ;
Ramsay, CS ;
Xie, H ;
Roberts, WL .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2004, 122 (03) :332-337