Effect of octopus tissue stabilizer on cardiac output during off-pump coronary artery bypass graft surgery

被引:2
作者
Ammannaya, Ganesh Kumar K. [1 ]
Basantwani, Shakuntala [1 ]
Mishra, Prashant [1 ]
Khandekar, Jayant, V [1 ]
机构
[1] Lokmanya Tilak Municipal Med Coll & Gen Hosp, Dept Cardiovasc & Thorac Surg, Mumbai, Maharashtra, India
关键词
tissue stabilizer; cardiac output; off-pump coronary artery bypass graft surgery; ON-PUMP; CARDIOPULMONARY BYPASS; HEMODYNAMIC-CHANGES; OUTCOMES;
D O I
10.5114/kitp.2019.86358
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction: Significant hemodynamic derangements can occur during off-pump coronary artery bypass graft (OPCAB) surgery resulting from the displacement of the beating heart, which may necessitate conversion to on-pump surgery. Aim: We proposed to evaluate the alterations in hemodynamic parameters in patients during the course of anastomosis in OPCAB surgery using the Octopus tissue stabilizer. Material and methods: In 100 consecutive patients undergoing OPCAB surgery, hemodynamic variables including cardiac output (CO), heart rate (HR), mean arterial pressure (MAP) and central venous pressure (CVP) were recorded at baseline, during each coronary artery anastomosis at 2 min, 10 min and after release of the Octopus tissue stabilizer. Results: CO decreased significantly after target stabilization and during all coronary anastomoses (5.42 +/- 1.1 l/min at baseline, 4.26 +/- 1.02 1/min at 2 min and 3.92 +/- 0.98 l/min at 10 min; p < 0.001), with the greatest decrease noted during obtuse marginal (OM) branch of left circumflex artery anastomosis (3.67 +/- 0.86 l/min at 2 min and 3.38 +/- 0.78 l/min at 10 min). Inotropic drugs were required to maintain mean arterial pressure (MAP) > 60 mm Hg in 43 patients, which was most frequently noted during OM anastomosis (p < 0.001). The incidence of bradycardia requiring inotropcs was noted to be the highest during left anterior descending (LAD) artery anastomosis (p = 0.002). Conclusions: During OPCAB surgery using the Octopus for coronary target stabilization, CO decreased the most during OM anastomosis requiring inotropes, while bradycardia was most frequent during LAD anastomosis. Careful monitoring and management of hemodynamic variables are therefore of utmost importance to avoid conversion to on-pump surgery.
引用
收藏
页码:69 / 73
页数:5
相关论文
共 12 条
[1]   Coronary artery bypass grafting without cardiopulmonary bypass and without interruption of native coronary flow using a novel anastomosis site restraining device (''Octopus'') [J].
Borst, C ;
Jansen, EWL ;
Tulleken, CAF ;
Grundeman, PF ;
Beck, HJM ;
vanDongen, JWF ;
Hodde, KC ;
Bredee, JJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (06) :1356-1364
[2]   Current evidence of coronary artery bypass grafting off-pump versus on-pump: a systematic review with meta-analysis of over 16 900 patients investigated in randomized controlled trialsaEuro [J].
Deppe, Antje-Christin ;
Arbash, Wasim ;
Kuhn, Elmar W. ;
Slottosch, Ingo ;
Scherner, Maximilian ;
Liakopoulos, Oliver J. ;
Choi, Yeong-Hoon ;
Wahlers, Thorsten .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2016, 49 (04) :1031-1041
[3]   Current outcomes of off-pump versus on-pump coronary artery bypass grafting: evidence from randomized controlled trials [J].
Fudulu, Daniel ;
Benedetto, Umberto ;
Pecchinenda, Gustavo Guida ;
Chivasso, Pierpaolo ;
Bruno, Vito Domenico ;
Rapetto, Filippo ;
Bryan, Alan ;
Angelini, Gianni Davide .
JOURNAL OF THORACIC DISEASE, 2016, 8 :S758-S771
[4]   Coronary artery bypass grafting without cardiopulmonary bypass using the octopus method:: Results in the first one hundred patients [J].
Jansen, EWL ;
Borst, C ;
Lahpor, JR ;
Gründeman, PF ;
Eefting, FD ;
Nierich, A ;
de Medina, EOR ;
Bredée, JJ .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1998, 116 (01) :60-67
[5]   The uncalibrated pulse contour cardiac output during off-pump coronary bypass surgery: performance in patients with a low cardiac output status and a reduced left ventricular function [J].
Jo, Youn Yi ;
Song, Jong Wook ;
Yoo, Young Chul ;
Park, Ji Young ;
Shim, Jae Kwang ;
Kwak, Young Lan .
KOREAN JOURNAL OF ANESTHESIOLOGY, 2011, 60 (04) :237-243
[6]   Accuracy and precision of non-invasive cardiac output monitoring devices in perioperative medicine: a systematic review and meta-analysis [J].
Joosten, A. ;
Desebbe, O. ;
Suehiro, K. ;
Murphy, L. S. -L. ;
Essiet, M. ;
Alexander, B. ;
Fischer, M. -O. ;
Barvais, L. ;
Van Obbergh, L. ;
Maucort-Boulch, D. ;
Cannesson, M. .
BRITISH JOURNAL OF ANAESTHESIA, 2017, 118 (03) :298-310
[7]   Off-pump coronary artery bypass grafting improves short-term outcomes in high-risk patients compared with on-pump coronary artery bypass grafting: Meta-analysis [J].
Kowalewski, Mariusz ;
Pawliszak, Wojciech ;
Malvindi, Pietro Giorgio ;
Bokszanski, Marek Pawel ;
Perlinski, Damian ;
Raffa, Giuseppe Maria ;
Kowalkowska, Magdalena Ewa ;
Zaborowska, Katarzyna ;
Navarese, Eliano Pio ;
Kolodziejczak, Michalina ;
Kowalewski, Janusz ;
Tarelli, Giuseppe ;
Taggart, David Paul ;
Anisimowicz, Lech .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2016, 151 (01) :60-+
[8]   Change in right ventricular function during off-pump coronary artery bypass graft surgery [J].
Kwak, YL ;
Oh, YJ ;
Jung, SM ;
Yoo, KJ ;
Lee, JH ;
Hong, YW .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2004, 25 (04) :572-577
[9]   Analysis of hemodynamic changes during beating heart surgical procedures [J].
Mathison, M ;
Edgerton, JR ;
Horswell, JL ;
Akin, JJ ;
Mack, MJ .
ANNALS OF THORACIC SURGERY, 2000, 70 (04) :1355-1360
[10]   Heart displacement during off-pump CABG: How well is it tolerated? [J].
Nierich, AP ;
Diephuis, J ;
Jansen, EWL ;
Borst, C ;
Knape, JTA .
ANNALS OF THORACIC SURGERY, 2000, 70 (02) :466-472