Which activity monitor to use? Validity, reproducibility and user friendliness of three activity monitors

被引:68
作者
Berendsen, Brenda A. J. [1 ]
Hendriks, Marike R. C. [1 ]
Meijer, Kenneth [1 ]
Plasqui, Guy [2 ]
Schaper, Nicolaas C. [3 ]
Savelberg, Hans H. C. M. [1 ]
机构
[1] Maastricht Univ, Med Ctr, Sch Nutr Toxicol & Metab, Dept Human Movement Sci,NUTRIM, NL-6200 MD Maastricht, Netherlands
[2] Maastricht Univ, Med Ctr, Sch Nutr Toxicol & Metab, Dept Human Biol,NUTRIM, NL-6200 MD Maastricht, Netherlands
[3] Maastricht Univ, Med Ctr, Sch Publ Hlth & Primary Care, Dept Internal Med,CAPHRI, NL-6200 MD Maastricht, Netherlands
关键词
Accelerometer; Wearing comfort; Posture classification; Sedentary; Feasibility; Reliability; Physical activity measurement; PHYSICAL-ACTIVITY; ENERGY-EXPENDITURE; METABOLIC SYNDROME; SEDENTARY TIME; ADULTS; VALIDATION; ACCELEROMETERS; RELIABILITY; POSTURE; MOTION;
D O I
10.1186/1471-2458-14-749
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: Health is associated with amount of daily physical activity. Recently, the identification of sedentary time as an independent factor, has gained interest. A valid and easy to use activity monitor is needed to objectively investigate the relationship between physical activity, sedentary time and health. We compared validity and reproducibility of physical activity measurement and posture identification of three activity monitors, as well as user friendliness. Methods: Healthy volunteers wore three activity monitors simultaneously: ActivPAL3, ActiGraphGT3X and CAM. Data were acquired under both controlled (n = 5) and free-living conditions (n = 9). The controlled laboratory measurement, that included standardized walking intensity and posture allocation, was performed twice. User friendliness was evaluated with a questionnaire. Posture classification was compared with direct observation (controlled measurement) and with diaries (free living). Accelerometer intensity accuracy was tested by correlations with walking speed. User friendliness was compared between activity monitors. Results: Reproducibility was at least substantial in all monitors. The difference between the two CAM measurements increased with walking intensity. Amount of correct posture classification by ActivPAL3 was 100.0% (kappa 0.98), 33.9% by ActiGraphGT3X (kappa 0.29) and 100.0% by CAM (kappa 0.99). Correlations between accelerometer intensity and walking speed were 0.98 for ActivPAL3, 1.00 for ActiGraphGT3X and 0.98 for CAM. ICCs between activity monitors and diary were 0.98 in ActivPAL3, 0.59 and 0.96 in ActiGraphGT3X and 0.98 in CAM. ActivPAL3 and ActiGraphGT3X had higher user friendliness scores than the CAM. Conclusions: The ActivPAL3 is valid, reproducible and user friendly. The posture classification by the ActiGraphGT3X is not valid, but reflection of walking intensity and user friendliness are good. The CAM is valid; however, reproducibility at higher walking intensity and user friendliness might cause problems. Further validity studies in free living are recommended.
引用
收藏
页数:11
相关论文
共 32 条
[1]   Objective Physical Activity Assessment in Patients With Chronic Organ Failure: A Validation Study of a New Single-Unit Activity Monitor [J].
Annegarn, Janneke ;
Spruit, Martijn A. ;
Uszko-Lencer, Nicole H. M. K. ;
Vanbelle, Sophie ;
Savelberg, Hans H. C. M. ;
Schols, Annemie M. W. J. ;
Wouters, Emiel F. M. ;
Meijer, Kenneth .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2011, 92 (11) :1852-1857
[2]  
[Anonymous], 2009, GUIDELINES HAND HYGI, P10
[3]   Sedentary Activity Associated With Metabolic Syndrome Independent of Physical Activity [J].
Bankoski, Andrea ;
Harris, Tamara B. ;
McClain, James J. ;
Brychta, Robert J. ;
Caserotti, Paolo ;
Chen, Kong Y. ;
Berrigan, David ;
Troiano, Richard P. ;
Koster, Annemarie .
DIABETES CARE, 2011, 34 (02) :497-503
[4]   Effects of placement and orientation of body-fixed accelerometers on the assessment of energy expenditure during walking [J].
Bouten, CVC ;
Sauren, AAHJ ;
Verduin, M ;
Janssen, JD .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1997, 35 (01) :50-56
[5]   Accuracy of Intensity and Inclinometer Output of Three Activity Monitors for Identification of Sedentary Behavior and Light-Intensity Activity [J].
Carr, Lucas J. ;
Mahar, Matthew T. .
JOURNAL OF OBESITY, 2012, 2012 :1-9
[6]   Assessment of Wear/Nonwear Time Classification Algorithms for Triaxial Accelerometer [J].
Choi, Leena ;
Ward, Suzanne Capen ;
Schnelle, John F. ;
Buchowski, Maciej S. .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2012, 44 (10) :2009-2016
[7]   Validity and reliability of measures of television viewing time and other non-occupational sedentary behaviour of adults: a review [J].
Clark, Bronwyn K. ;
Sugiyama, Takemi ;
Healy, Genevieve N. ;
Salmon, Jo ;
Dunstan, David W. ;
Owen, Neville .
OBESITY REVIEWS, 2009, 10 (01) :7-16
[8]   Accelerometers and pedometers: methodology and clinical application [J].
Corder, Kirsten ;
Brage, Soren ;
Ekelund, Ulf .
CURRENT OPINION IN CLINICAL NUTRITION AND METABOLIC CARE, 2007, 10 (05) :597-603
[9]   Test-retest reliability of step counts with the ActivPAL™ device in common daily activities [J].
Dahlgren, Gunilla ;
Carlsson, Daniel ;
Moorhead, Anne ;
Hager-Ross, Charlotte ;
McDonough, Suzanne M. .
GAIT & POSTURE, 2010, 32 (03) :386-390
[10]   Minimal Intensity Physical Activity (Standing and Walking) of Longer Duration Improves Insulin Action and Plasma Lipids More than Shorter Periods of Moderate to Vigorous Exercise (Cycling) in Sedentary Subjects When Energy Expenditure Is Comparable [J].
Duvivier, Bernard M. F. M. ;
Schaper, Nicolaas C. ;
Bremers, Michelle A. ;
van Crombrugge, Glenn ;
Menheere, Paul P. C. A. ;
Kars, Marleen ;
Savelberg, Hans H. C. M. .
PLOS ONE, 2013, 8 (02)