Comparison of the shaping abilities of three nickel-titanium instrumentation systems using micro-computed tomography

被引:5
作者
Baek, Jin Yi [1 ]
Yoo, Hyun Mi [1 ]
Park, Dong Sung [1 ]
Oh, Tae Seok [1 ]
Kum, Kee Yeon [2 ,3 ]
Shin, Seung Yun [4 ]
Chang, Seok Woo [5 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Conservat Dent,Inst Oral Hlth Sci, Seoul, South Korea
[2] Seoul Natl Univ, Sch Dent, Dent Hosp, Dept Conservat Dent,Dent Res Inst, Seoul, South Korea
[3] Seoul Natl Univ, Sch Dent, Program BK21, Dent Hosp, Seoul, South Korea
[4] Kyung Hee Univ, Sch Dent, Dept Periodontol, Seoul 130701, South Korea
[5] Kyung Hee Univ, Sch Dent, Dept Conservat Dent, Seoul 130701, South Korea
基金
新加坡国家研究基金会;
关键词
canal shaping; centering ratio; micro-computed tomography; nickel-titanium instruments; transportation; ROOT-CANAL PREPARATION; SELF-ADJUSTING FILE; ROTARY INSTRUMENTS; TRANSPORTATION; PROTAPER; GEOMETRY; WAVEONE; MOLARS;
D O I
10.1016/j.jds.2013.12.002
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background/purpose: The purpose of this study was to compare the canal transportation (CTR) and centering ratio (CR) of Pro File (PF), Twisted File (IF), and Wave One (WO) nickel-titanium instrument systems and evaluate canal volume (CV) and surface area (SA) using micro-computed tomography (CT). Materials and methods: Eighteen extracted human mandibular molars with two separate mesial canals were selected. The specimens were randomly divided into three groups of six teeth. Therefore, twelve root canals were allocated for each group (n = 12): group 1, PF(#30/.06); group 2, TF(#30/.06); group 3, WO (primary) instrument systems. Working lengths were determined 0.5 mm short of the apical foramen. Specimens were scanned before and after root canal preparation. Scanned images were reconstructed and the effects of root canal preparation on the CV and SA were evaluated. Pre- and post-instrumentation cross-sectional images of 1, 3, 5, and 7 mm from the anatomical apex were obtained and the CTR and CR were compared. The data were analyzed by the Kruskal-Wallis test and linear mixed model with Bonferroni's correction. A P < 0.05 was considered to be significant. Results: Postoperative canals were larger and had greater SA, although these changes were not statistically significant (P > 0.05). At any levels (1-, 3-, 5-, and 7-mm), no significant difference was found in the amount of CTR among the groups (P > 0.05). At the 1-, 3-, and 7-mm levels there was no significant difference in the CR among the groups (P > 0.05). However, at the 5-mm level, WO group showed significantly smaller CR than PF group (P < 0.05). Conclusion: Within the limitations of this study, WO showed smaller CR than PF, which imply that careful use of WO in curved canals is recommended. Copyright (C) 2014, Association for Dental Sciences of the Republic of China. Published by Elsevier Taiwan LLC. All rights reserved.
引用
收藏
页码:111 / 117
页数:7
相关论文
共 24 条
  • [1] THE ANTI-CURVATURE FILING METHOD TO PREPARE THE CURVED ROOT-CANAL
    ABOURASS, M
    FRANK, AL
    GLICK, DH
    [J]. JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1980, 101 (05) : 792 - 794
  • [2] American Association Of Endodontists, 2003, AM ASS END GLOSS END
  • [3] Bergmans L, 2001, AM J DENT, V14, P324
  • [4] Root Canal Anatomy Preservation of WaveOne Reciprocating Files with or without Glide Path
    Berutti, Elio
    Paolino, Davide Salvatore
    Chiandussi, Giorgio
    Alovisi, Mario
    Cantatore, Giuseppe
    Castellucci, Arnaldo
    Pasqualini, Damiano
    [J]. JOURNAL OF ENDODONTICS, 2012, 38 (01) : 101 - 104
  • [5] Shaping ability and cleaning effectiveness of two single-file systems in severely curved root canals of extracted teeth: Reciproc and WaveOne versus Mtwo and ProTaper
    Buerklein, S.
    Hinschitza, K.
    Dammaschke, T.
    Schaefer, E.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2012, 45 (05) : 449 - 461
  • [6] Microscopic computerized tomographic evaluation of root canal transportation prepared with twisted or ground nickel-titanium rotary instruments
    Freire, Laila Gonzales
    Gavini, Giulio
    Branco-Barletta, Fernando
    Sanches-Cunha, Rodrigo
    dos Santos, Marcelo
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2011, 112 (06): : E143 - E148
  • [7] Mechanical properties of a new and improved nickel-titanium alloy for endodontic use: an evaluation of file flexibility
    Gambarini, Gianluca
    Gerosa, Roberto
    De Luca, Massimo
    Garala, Manish
    Testarelli, Luca
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2008, 105 (06): : 798 - 800
  • [8] Comparison of nickel-titanium and stainless steel hand-file instrumentation using computed tomography
    Gambill, JM
    Alder, M
    delRio, CE
    [J]. JOURNAL OF ENDODONTICS, 1996, 22 (07) : 369 - 375
  • [9] Comparison of Canal Transportation and Centering Ability of Twisted Files, Pathfile-ProTaper System, and Stainless Steel Hand K-Files by Using Computed Tomography
    Gergi, Richard
    Abou Rjeily, Joe
    Sader, Joseph
    Naaman, Alfred
    [J]. JOURNAL OF ENDODONTICS, 2010, 36 (05) : 904 - 907
  • [10] Hulsmann M., 2005, Endodontic Topics, V10, P30, DOI [10.1111/j.1601-1546.2005.00152.x, DOI 10.1111/J.1601-1546.2005.00152.X]