Second-trimester genetic sonogram for detection of fetal chromosomal abnormalities in a community-based antenatal testing unit

被引:26
作者
Bottalico, J. N. [1 ]
Chen, X.
Tartaglia, M.
Rosario, B.
Yarabothu, D.
Nelson, L.
机构
[1] Univ Med & Dent New Jersey, Sch Osteopath Med, Dept Obstet & Gynecol, Stratford, NJ 08084 USA
关键词
chromosomal anomaly; Down syndrome; genetic sonogram; pregnancy; ultrasonography; DOWN-SYNDROME; PRENATAL ULTRASOUND; NUCHAL FOLD; RISK; FETUSES; ULTRASONOGRAPHY; PREGNANCIES; EFFICACY;
D O I
10.1002/uog.6220
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective To evaluate the efficacy of the second-trimester genetic sonogram for the detection of Down syndrome and other chromosomal abnormalities in a community-based antenatal testing unit. Methods This was a retrospective study using data from two community hospital antenatal ultrasound units. Six hundred and sixty fetal ultrasound examinations in both at-risk (n = 581) and low-risk (n = 79) pregnancies were performed from 15 + 0 to 22 + 6 weeks' gestation and all cases were verified for outcome data. The sonographic detection of a major congenital anomaly or a sonographic marker (increased nuchal skinfold, short humerus, short femur, echogenic bowel, pyelectasis, echogenic intracardiac focus, absence or hypoplasia of fifth mid phalanx or choroid plexus cyst) was recorded. The entire group of 660 ultrasound examinations as well as subgroups with and without non-ultrasound risk factors for a fetal chromosomal abnormality were analyzed to determine the sensitivity, specificity, positive and negative predictive values and positive likelihood ratio for the detection of Down syndrome and other fetal chromosomal abnormalities. Results There were 32 (4.85%) chromosomal abnormalities in our study population. Twelve (3.75%) of these were Down syndrome, of which eight (66.6%) had a positive ultrasound examination in the second trimester. Six of seven (85.7%) of the trisomy 18 fetuses, 212 of the trisomy 13 fetuses and 213 of the non-mosaic 45,X fetuses had positive sonograms. The overall detection rate for chromosomal abnormalities was 20/32 (sensitivity, 62.5%; specificity, 80.7%; negative predictive value, 97.7%; positive predictive value, 14.2%; positive likelihood ratio, 3.24). Major structural defects and sonographic markers, excluding hypoplastic fifth digit and choroid plexus cyst, occurred significantly more frequently in Down syndrome cases compared with normal ones. Conclusions In a community-based antenatal testing unit we have demonstrated a detection rate for fetal Down syndrome with the second-trimester genetic sonogram that is comparable to the range of sensitivities reported by larger centers involving primarily high-risk patients. However, only 12 of the 32 fetal chromosomal abnormalities that we encountered were Down syndrome. Copyright (C) 2009 ISUOG. Published by John Wiley & Sons, Ltd.
引用
收藏
页码:161 / 168
页数:8
相关论文
共 22 条
[1]  
*AM MED ASS, 2003, INT CLASS DIS
[2]   The mid-trimester genetic sonogram [J].
Bahado-Singh, RO ;
Oz, UA ;
Mendilcioglu, I ;
Mahoney, MJ .
SEMINARS IN PERINATOLOGY, 2005, 29 (04) :209-214
[3]   The significance of the nuchal fold in the second trimester fetus [J].
Benacerraf, B .
PRENATAL DIAGNOSIS, 2002, 22 (09) :798-801
[4]   CAN SONOGRAPHERS RELIABLY IDENTIFY ANATOMIC FEATURES ASSOCIATED WITH DOWN SYNDROME IN FETUSES [J].
BENACERRAF, BR ;
CNANN, A ;
GELMAN, R ;
LABODA, LA ;
FRIGOLETTO, FD .
RADIOLOGY, 1989, 173 (02) :377-380
[5]   HUMERAL SHORTENING IN 2ND-TRIMESTER FETUSES WITH DOWN-SYNDROME [J].
BENACERRAF, BR ;
NEUBERG, D ;
FRIGOLETTO, FD .
OBSTETRICS AND GYNECOLOGY, 1991, 77 (02) :223-227
[6]   SOFT-TISSUE NUCHAL FOLD IN THE 2ND-TRIMESTER FETUS - STANDARDS FOR NORMAL MEASUREMENTS COMPARED WITH THOSE IN DOWN-SYNDROME [J].
BENACERRAF, BR ;
FRIGOLETTO, FD .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1987, 157 (05) :1146-1149
[7]   Second trimester prenatal ultrasound and screening for Down syndrome [J].
Benn, Peter A. ;
Egan, James F. X. .
PRENATAL DIAGNOSIS, 2007, 27 (09) :884-884
[8]   Choroid plexus cysts: Not associated with Down syndrome [J].
Bromley, B ;
Lieberman, E ;
Benacerraf, BR .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1996, 8 (04) :232-235
[9]   Efficacy of screening for fetal Down syndrome in the United States from 1974 to 1997 [J].
Egan, JFX ;
Benn, P ;
Borgida, AF ;
Rodis, JF ;
Campbell, WA ;
Vintzileos, AM .
OBSTETRICS AND GYNECOLOGY, 2000, 96 (06) :979-985
[10]   The genetic sonogram in second trimester Down syndrome screening [J].
Egan, JFX .