Dosimetric Comparison of Real-Time MRI-Guided Tri-Cobalt-60 Versus Linear Accelerator-Based Stereotactic Body Radiation Therapy Lung Cancer Plans

被引:11
作者
Wojcieszynski, Andrzej P. [1 ]
Hill, Patrick M. [1 ]
Rosenberg, Stephen A. [1 ]
Hullett, Craig R. [1 ]
Labby, Zacariah E. [1 ]
Paliwal, Bhudatt [1 ]
Geurts, Mark W. [1 ]
Bayliss, R. Adam [1 ]
Bayouth, John E. [1 ]
Harari, Paul M. [1 ]
Bassetti, Michael F. [1 ]
Baschnagel, Andrew M. [1 ]
机构
[1] Univ Wisconsin, Dept Human Oncol, Sch Med & Publ Hlth, 600 Highland Ave,K4-B100, Madison, WI 53792 USA
关键词
stereotactic body radiation therapy; 4DCT; NSCLC; volumetric modulated; 4-D computed tomography; RADIOTHERAPY; CYBERKNIFE; CARCINOMA; TRACKING; SYSTEM; VOLUME;
D O I
10.1177/1533034617691407
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Magnetic resonance imaging-guided radiation therapy has entered clinical practice at several major treatment centers. Treatment of early-stage non-small cell lung cancer with stereotactic body radiation therapy is one potential application of this modality, as some form of respiratory motion management is important to address. We hypothesize that magnetic resonance imaging-guided tri-cobalt-60 radiation therapy can be used to generate clinically acceptable stereotactic body radiation therapy treatment plans. Here, we report on a dosimetric comparison between magnetic resonance imaging-guided radiation therapy plans and internal target volume-based plans utilizing volumetric-modulated arc therapy. Materials and Methods: Ten patients with early-stage non-small cell lung cancer who underwent radiation therapy planning and treatment were studied. Following 4-dimensional computed tomography, patient images were used to generate clinically deliverable plans. For volumetric-modulated arc therapy plans, the planning tumor volume was defined as an internal target volume + 0.5 cm. For magnetic resonance imaging-guided plans, a single mid-inspiratory cycle was used to define a gross tumor volume, then expanded 0.3 cm to the planning tumor volume. Treatment plan parameters were compared. Results: Planning tumor volumes trended larger for volumetric-modulated arc therapy-based plans, with a mean planning tumor volume of 47.4 mL versus 24.8 mL for magnetic resonance imaging-guided plans (P = .08). Clinically acceptable plans were achievable via both methods, with bilateral lung V20, 3.9% versus 4.8% (P = .62). The volume of chest wall receiving greater than 30 Gy was also similar, 22.1 versus 19.8 mL (P = .78), as were all other parameters commonly used for lung stereotactic body radiation therapy. The ratio of the 50% isodose volume to planning tumor volume was lower in volumetric-modulated arc therapy plans, 4.19 versus 10.0 (P < .001). Heterogeneity index was comparable between plans, 1.25 versus 1.25 (P = .98). Conclusion: Magnetic resonance imaging-guided tri-cobalt-60 radiation therapy is capable of delivering lung high-quality stereotactic body radiation therapy plans that are clinically acceptable as compared to volumetric-modulated arc therapy-based plans. Real-time magnetic resonance imaging provides the unique capacity to directly observe tumor motion during treatment for purposes of motion management.
引用
收藏
页码:366 / 372
页数:7
相关论文
共 14 条
[1]   Effects of breathing variation on gating window internal target volume in respiratory gated radiation therapy [J].
Cai, Jing ;
McLawhorn, Robert ;
Read, Paul W. ;
Larner, James M. ;
Yin, Fang-fang ;
Benedict, Stanley H. ;
Sheng, Ke .
MEDICAL PHYSICS, 2010, 37 (08) :3927-3934
[2]   Radical stereotactic radiosurgery with real-time tumor motion tracking in the treatment of small peripheral lung tumors [J].
Collins, Brian T. ;
Erickson, Kelly ;
Reichner, Cristina A. ;
Collins, Sean P. ;
Gagnon, Gregory J. ;
Dieterich, Sonja ;
McRae, Don A. ;
Zhang, Ying ;
Yousefi, Shadi ;
Levy, Elliot ;
Chang, Thomas ;
Jamis-Dow, Carlos ;
Banovac, Filip ;
Anderson, Eric D. .
RADIATION ONCOLOGY, 2007, 2 (1)
[3]   STEREOTACTIC BODY RADIATION THERAPY FOR EARLY-STAGE NON-SMALL-CELL LUNG CARCINOMA: FOUR-YEAR RESULTS OF A PROSPECTIVE PHASE II STUDY [J].
Fakiris, Achilles J. ;
McGarry, Ronald C. ;
Yiannoutsos, Constantin T. ;
Papiez, Lech ;
Williams, Mark ;
Henderson, Mark A. ;
Timmerman, Robert .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03) :677-682
[4]   To gate or not to gate - dosimetric evaluation comparing Gated vs. ITV-based methodologies in stereotactic ablative body radiotherapy (SABR) treatment of lung cancer [J].
Kim, Joshua ;
Wu, Qixue ;
Zhao, Bo ;
Wen, Ning ;
Ajlouni, Munther ;
Movsas, Benjamin ;
Chetty, Indrin J. .
RADIATION ONCOLOGY, 2016, 11
[5]   Dose-Volume Metrics Associated With Radiation Pneumonitis After Stereotactic Body Radiation Therapy for Lung Cancer [J].
Matsuo, Yukinori ;
Shibuya, Keiko ;
Nakamura, Mitsuhiro ;
Narabayashi, Masaru ;
Sakanaka, Katsuyuki ;
Ueki, Nami ;
Miyagi, Ken ;
Norihisa, Yoshiki ;
Mizowaki, Takashi ;
Nagata, Yasushi ;
Hiraoka, Masahiro .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (04) :E545-E549
[6]   The ViewRay System: Magnetic Resonance-Guided and Controlled Radiotherapy [J].
Mutic, Sasa ;
Dempsey, James F. .
SEMINARS IN RADIATION ONCOLOGY, 2014, 24 (03) :196-199
[7]   Lung tumor tracking during stereotactic radiotherapy treatment with the CyberKnife:: Marker placement and early results [J].
Nuyttens, J. J. ;
Prevost, J. -B. ;
Praag, J. ;
Hoogeman, M. ;
Van Klaveren, R. J. ;
Levendag, P. C. ;
Pattynama, P. M. T. .
ACTA ONCOLOGICA, 2006, 45 (07) :961-965
[8]   A dose homogeneity and conformity evaluation between ViewRay and pinnacle-based linear accelerator IMRT treatment plans [J].
Saenz, Daniel L. ;
Paliwal, Bhudatt R. ;
Bayouth, John E. .
JOURNAL OF MEDICAL PHYSICS, 2014, 39 (02) :64-70
[9]   Stereotactic Body Radiation Therapy for Inoperable Early Stage Lung Cancer [J].
Timmerman, Robert ;
Paulus, Rebecca ;
Galvin, James ;
Michalski, Jeffrey ;
Straube, William ;
Bradley, Jeffrey ;
Fakiris, Achilles ;
Bezjak, Andrea ;
Videtic, Gregory ;
Johnstone, David ;
Fowler, Jack ;
Gore, Elizabeth ;
Choy, Hak .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2010, 303 (11) :1070-1076
[10]   Stereotactic radiotherapy with real-time tumor tracking for non-small cell lung cancer: Clinical outcome [J].
van Zyp, Noelle C. van der Voort ;
Prevost, Jean-Briac ;
Hoogeman, Mischa S. ;
Praag, John ;
van der Holt, Bronno ;
Levendag, Peter C. ;
van Klaveren, Robertus J. ;
Pattynama, Peter ;
Nuyttens, Joost J. .
RADIOTHERAPY AND ONCOLOGY, 2009, 91 (03) :296-300