The Impact of Storage Time on the Wear Rates of Ultrahigh-Molecular-Weight Polyethylene Acetabular Liners in Hip Simulators

被引:4
作者
Fan Weimin [1 ]
Song Huanghe [1 ]
Li Xiang [1 ]
Liu Feng [1 ]
Wang Qing [1 ]
机构
[1] Nanjing Univ, Hosp Nanjing Med 1, Dept Orthoped, Nanjing 210029, Peoples R China
关键词
storage time; ultrahigh-molecular-weight polyethylene (UHMWPE); wear; CROSS-LINKED POLYETHYLENE; IN-VIVO; SHELF-LIFE; GAMMA-STERILIZATION; FEMORAL-HEAD; ARTHROPLASTY; UHMWPE; DEGRADATION; PROSTHESES;
D O I
10.1016/j.arth.2008.01.308
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The aim of the study is to explore the impact of storage time on wear rates. Two groups of acetabular liners with a storage time of 1 and 4 years were tested on 2 hip simulators of the same type. There were 6 liners in each group. Gravimetric analysis was performed every 500 000 cycles for a total of 3 million cycles. The mean wear rate for the group of 4-year-old liners (36.3 mg/million cycles) was significantly higher than that for the 1-year-old group (23.1 mg/million cycles) (P < .05). After the last gravimetric analysis, scanning electron microscopy was used to observe the wear patterns of the bearing surfaces. This study found that wear resistance decreased as storage time increased.
引用
收藏
页码:543 / 548
页数:6
相关论文
共 28 条
  • [1] MECHANISM OF AGING IN IRRADIATED POLYMERS
    BIRKINSHAW, C
    BUGGY, M
    DALY, S
    ONEILL, M
    [J]. POLYMER DEGRADATION AND STABILITY, 1988, 22 (03) : 285 - 294
  • [2] Bohl JR, 1999, CLIN ORTHOP RELAT R, P28
  • [3] Third-body wear of highly cross-linked polyethylene in a hip simulator
    Bragdon, CR
    Jasty, M
    Muratoglu, OK
    O'Connor, DO
    Harris, WH
    [J]. JOURNAL OF ARTHROPLASTY, 2003, 18 (05) : 553 - 561
  • [4] Impact of gamma sterilization on clinical performance of polyethylene in the knee
    Collier, JP
    Sperling, DK
    Currier, JH
    Sutula, LC
    Saum, KA
    Mayor, MB
    [J]. JOURNAL OF ARTHROPLASTY, 1996, 11 (04) : 377 - 389
  • [5] Collier JP, 1996, CLIN ORTHOP RELAT R, P76
  • [6] The basis for a second-generation highly cross-linked UHMWPE
    Dumbleton, John H.
    D'Antonio, James A.
    Manley, Michael T.
    Capello, William N.
    Wang, Aiguo
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (453) : 265 - 271
  • [7] Degradation of mechanical behavior in UHMWPE after natural and accelerated aging
    Edidin, AA
    Jewett, CW
    Kalinowski, A
    Kwarteng, K
    Kurtz, SM
    [J]. BIOMATERIALS, 2000, 21 (14) : 1451 - 1460
  • [8] The quantitative assessment of UHMWPE wear debris produced in hip simulator testing: the influence of head material and roughness, motion and loading
    Elfick, APD
    Smith, SL
    Green, SM
    Unsworth, A
    [J]. WEAR, 2001, 249 (5-6) : 517 - 527
  • [9] PRELIMINARY-STUDY OF THE EFFECT OF AGING FOLLOWING IRRADIATION ON THE WEAR OF ULTRAHIGH-MOLECULAR-WEIGHT POLYETHYLENE
    FISHER, J
    CHAN, KL
    HAILEY, JL
    SHAW, D
    STONE, M
    [J]. JOURNAL OF ARTHROPLASTY, 1995, 10 (05) : 689 - 692
  • [10] Bone-resorbing cytokines in serum of patients with aseptic loosening of hip prostheses
    Granchi, D
    Verri, E
    Ciapetti, G
    Stea, S
    Savarino, L
    Sudanese, A
    Mieti, M
    Rotini, R
    Dallari, D
    Zinghi, G
    Montanaro, L
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (05): : 912 - 917