Automized procedures for the determination of ozone and ammonia contents in air by using the chromatomembrane method for gas-liquid extraction

被引:17
作者
Erxleben, H
Simon, J
Moskvin, LN
Vladimirovna, LO
Nikitina, TG
机构
[1] Free Univ Berlin, Dept Chem, Inst Inorgan & Analyt Chem, D-14195 Berlin, Germany
[2] St Petersburg State Univ, Dept Chem, St Petersburg 198904, Russia
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 2000年 / 366卷 / 04期
关键词
D O I
10.1007/s002160050067
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Chromatomembrane cells (CMC) operate as unique manifolds for extraction and preconcentration procedures in computer controlled now-injection-analysis (FIA). By coupling to an ion chromatograph and to a conductometer, respectively, instrumentation is obtained that allows the pretreatment and the detection of ozone- and ammonia-containing samples after absorption of the gaseous constituents of air inside a chromatomembrane cell. The analysis of air even in the presence of liquid aerosols is discussed.
引用
收藏
页码:332 / 335
页数:4
相关论文
共 18 条
[1]  
BECKER KH, 1985, AIR POLLUTION PHOTOC, P100
[2]   Determination of small quantities of nitrogen oxides in air by ion chromatography using a chromatomembrane cell for preconcentration [J].
Erxleben, H ;
Moskvin, LN ;
Nikitina, TG ;
Simon, J .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 361 (03) :324-325
[3]   PERMEATION DENUDER FOR SAMPLING AND CONTINUOUS ANALYSIS OF GASES .1. SYSTEM CONFIGURATION, BASIC STUDIES AND APPLICATION TO ATMOSPHERIC AMMONIA AND SULFUR-DIOXIDE [J].
FRENZEL, W .
ANALYTICA CHIMICA ACTA, 1994, 291 (03) :305-320
[4]   OZONE FADING OF NATURAL ORGANIC COLORANTS - MECHANISMS AND PRODUCTS OF THE REACTION OF OZONE WITH INDIGOS [J].
GROSJEAN, D ;
WHITMORE, PM ;
CASS, GR .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1988, 22 (03) :292-298
[5]   FLOW-INJECTION ANALYSIS WITH THE CHROMATOMEMBRANE - A NEW DEVICE FOR GASEOUS/LIQUID AND LIQUID/LIQUID EXTRACTION [J].
MOSKVIN, LN ;
SIMON, J .
TALANTA, 1994, 41 (10) :1765-1769
[6]   CHROMATOMEMBRANE METHOD FOR THE CONTINUOUS SEPARATION OF SUBSTANCES [J].
MOSKVIN, LN .
JOURNAL OF CHROMATOGRAPHY A, 1994, 669 (1-2) :81-87
[7]  
Moskvin LN, 1998, LAB ROBOTICS AUTOMAT, V10, P3, DOI 10.1002/(SICI)1098-2728(1998)10:1<3::AID-LRA2>3.0.CO
[8]  
2-8
[9]   SUMMATION METHOD FOR MONITORING OZONE IN THE ATMOSPHERE [J].
REMLER, P ;
KOSMUS, W .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1988, 329 (08) :871-874
[10]   Does the chromatomembrane cell improve the quality of environmental analysis? [J].
Simon, J ;
Moskvin, LN .
TALANTA, 1999, 49 (05) :985-988