In vivo muscle morphology comparison in post-stroke survivors using ultrasonography and diffusion tensor imaging

被引:14
作者
Korting, Clara [1 ]
Schlippe, Marius [1 ]
Petersson, Sven [2 ,3 ]
Pennati, Gaia Valentina [4 ]
Tarassova, Olga [5 ]
Arndt, Anton [5 ,6 ]
Finni, Taija [7 ]
Zhao, Kangqiao [1 ]
Wang, Ruoli [1 ,8 ,9 ]
机构
[1] Royal Inst Technol, Dept Mech, Stockholm, Sweden
[2] Karolinska Univ Hosp, Dept Med Radiat Phys & Nucl Med, Stockholm, Sweden
[3] Karolinska Inst, Dept Clin Sci Intervent & Technol, Stockholm, Sweden
[4] Karolinska Inst, Danderyd Hosp, Dept Clin Sci, Div Rehabil Med, Stockholm, Sweden
[5] Swedish Sch Sport & Hlth Sci, Stockholm, Sweden
[6] Karolinska Inst, Dept CLINTEC, Stockholm, Sweden
[7] Univ Jyvaskyla, Fac Sport & Hlth Sci, Jyvaskyla, Finland
[8] Karolinska Inst, Dept Childrens & Womens Hlth, Stockholm, Sweden
[9] Royal Inst Technol, KTH Biomex Ctr, Stockholm, Sweden
关键词
GASTROCNEMIUS-MUSCLE; ULTRASOUND MEASUREMENTS; STROKE; ARCHITECTURE; SPASTICITY; PARAMETERS; THICKNESS; REFLEX;
D O I
10.1038/s41598-019-47968-x
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Skeletal muscle architecture significantly influences the performance capacity of a muscle. A DTI-based method has been recently considered as a new reference standard to validate measurement of muscle structure in vivo. This study sought to quantify muscle architecture parameters such as fascicle length (FL), pennation angle (PA) and muscle thickness (t(m)) in post-stroke patients using diffusion tensor imaging (DTI) and to quantitatively compare the differences with 2D ultrasonography (US) and DTI. Muscle fascicles were reconstructed to examine the anatomy of the medial gastrocnemius, posterior soleus and tibialis anterior in seven stroke survivors using US- and DTI-based techniques, respectively. By aligning the US and DTI coordinate system, DTI reconstructed muscle fascicles at the same scanning plane of the US data can be identified. The architecture parameters estimated based on two imaging modalities were further compared. Significant differences were observed for PA and t m between two methods. Although mean FL was not significantly different, there were considerable intra-individual differences in FL and PA. On the individual level, parameters measured by US agreed poorly with those from DTI in both deep and superficial muscles. The significant differences in muscle parameters we observed suggested that the DTI-based method seems to be a better method to quantify muscle architecture parameters which can provide important information for treatment planning and to personalize a computational muscle model.
引用
收藏
页数:11
相关论文
共 35 条
[1]  
[Anonymous], 2016 38 ANN INT C IE
[2]  
[Anonymous], AM J PHYSL HEART CIR
[3]  
[Anonymous], AM J PHYSL HEART CIR
[4]  
[Anonymous], 2004, J REHABILITATION RES
[5]  
[Anonymous], STROKE RES TREATMENT
[6]  
[Anonymous], BIOMED RESEARCH INTE
[7]   ANATOMICAL INFORMATION IS NEEDED IN ULTRASOUND IMAGING OF MUSCLE TO AVOID POTENTIALLY SUBSTANTIAL ERRORS IN MEASUREMENT OF MUSCLE GEOMETRY [J].
Benard, Menno R. ;
Becher, Jules G. ;
Harlaar, Jaap ;
Huijing, Peter A. ;
Jaspers, Richard T. .
MUSCLE & NERVE, 2009, 39 (05) :652-665
[8]   Matrix metabolism rate differs in functionally distinct tendons [J].
Birch, Helen L. ;
Worboys, Sarah ;
Eissa, Sabry ;
Jackson, Brendan ;
Strassburg, Sandra ;
Clegg, Peter D. .
MATRIX BIOLOGY, 2008, 27 (03) :182-189
[9]   Three-dimensional architecture of the whole human soleus muscle in vivo [J].
Bolsterlee, Bart ;
Finni, Taija ;
D'Souza, Arkiev ;
Eguchi, Junya ;
Clarke, Elizabeth C. ;
Herbert, Robert D. .
PEERJ, 2018, 6
[10]   Ultrasound imaging of the human medial gastrocnemius muscle: how to orient the transducer so that muscle fascicles lie in the image plane [J].
Bolsterlee, Bart ;
Gandevia, Simon C. ;
Herbert, Robert D. .
JOURNAL OF BIOMECHANICS, 2016, 49 (07) :1002-1008