The "perfect" reader study

被引:19
作者
Gennaro, Gisella [1 ]
机构
[1] IRCCS, IOV, Breast Imaging Unit, Via Gattamelata 64, I-35128 Padua, Italy
关键词
Reader study; Clinical performance; Diagnostic accuracy; Technology assessment; Bias; CLINICAL-TRIAL; LUNG NODULES; PERFORMANCE; PHANTOM; CURVES; DESIGN; TIME; BIAS;
D O I
10.1016/j.ejrad.2018.03.014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A reader study, i.e. a diagnostic accuracy study aiming to assess clinical performance of one technology versus another, on the basis of image interpretation by a group of human readers, requires an accurate design, with the precise definition of each element concurring to the study itself. In this paper, the main issues to take into consideration when designing reader studies are described, and the characteristics of a number of indices of diagnostic accuracy are summarized. Special care is given to the description of the multiple sources of bias, which should be controlled in order to assure study soundness and allow consistent conclusions. Although a "perfect" reader study does not exist, because bias cannot be completely eliminated, a good study would be designed to minimize the bias effects, and possible unavoidable bias should be described in study reporting and used to provide a correct interpretation of results.
引用
收藏
页码:139 / 146
页数:8
相关论文
共 37 条
[1]  
[Anonymous], 2011, STAT METHODS DIAGNOS, DOI DOI 10.1002/9780470906514
[2]   ASSESSMENT OF RADIOLOGIC TESTS - CONTROL OF BIAS AND OTHER DESIGN CONSIDERATIONS [J].
BEGG, CB ;
MCNEIL, BJ .
RADIOLOGY, 1988, 167 (02) :565-569
[3]   Correcting for exposure misclassification using an alloyed gold standard [J].
Brenner, H .
EPIDEMIOLOGY, 1996, 7 (04) :406-410
[4]   Dual-energy CT iodine overlay technique for characterization of renal masses as cyst or solid: a phantom feasibility study [J].
Brown, C. L. ;
Hartman, R. P. ;
Dzyubak, O. P. ;
Takahashi, N. ;
Kawashima, A. ;
McCollough, C. H. ;
Bruesewitz, M. R. ;
Primak, A. M. ;
Fletcher, J. G. .
EUROPEAN RADIOLOGY, 2009, 19 (05) :1289-1295
[5]   Analysis of location specific observer performance data: Validated extensions of the jackknife free-response (JAFROC) method [J].
Chakraborty, Dev P. .
ACADEMIC RADIOLOGY, 2006, 13 (10) :1187-1193
[6]   Contralateral lesions detected by preoperative MRI in patients with recently diagnosed breast cancer: Application of MR CAD in differentiation of benign and malignant lesions [J].
Cho, Nariya ;
Kim, Sun Mi ;
Park, Jeong Seon ;
Jang, Mijung ;
Kim, Soo-Yeon ;
Chang, Jung Min ;
Moon, Woo Kyung .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (07) :1520-1526
[7]   Multi-Reader Multi-Case Studies Using the Area under the Receiver Operator Characteristic Curve as a Measure of Diagnostic Accuracy: Systematic Review with a Focus on Quality of Data Reporting [J].
Dendumrongsup, Thaworn ;
Plumb, Andrew A. ;
Halligan, Steve ;
Fanshawe, Thomas R. ;
Altman, Douglas G. ;
Mallett, Susan .
PLOS ONE, 2014, 9 (12)
[8]  
DOrsi C., 2013, ACR BIRADS. atlas, breast imaging reporting and data sys-tem, V5th
[9]   THE EFFICACY OF DIAGNOSTIC-IMAGING [J].
FRYBACK, DG ;
THORNBURY, JR .
MEDICAL DECISION MAKING, 1991, 11 (02) :88-94
[10]   The prevalence effect in a laboratory environment: Changing the confidence ratings [J].
Gur, David ;
Bandos, Andriy I. ;
Fuhrman, Carl R. ;
Klym, Amy H. ;
King, Jill L. ;
Rockette, Howard E. .
ACADEMIC RADIOLOGY, 2007, 14 (01) :49-53