Geochemical detection of carbon dioxide in dilute aquifers

被引:96
作者
Carroll, Susan [1 ]
Hao, Yue [1 ]
Aines, Roger [1 ]
机构
[1] Lawrence Livermore Natl Lab, Chem Mat Earth & Life Sci Div, Livermore, CA 94550 USA
来源
GEOCHEMICAL TRANSACTIONS | 2009年 / 10卷
关键词
HIGH-PLAINS; STORAGE; CO2; SEQUESTRATION; LEAKAGE; GAS;
D O I
10.1186/1467-4866-10-4
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
Background: Carbon storage in deep saline reservoirs has the potential to lower the amount of CO2 emitted to the atmosphere and to mitigate global warming. Leakage back to the atmosphere through abandoned wells and along faults would reduce the efficiency of carbon storage, possibly leading to health and ecological hazards at the ground surface, and possibly impacting water quality of near-surface dilute aquifers. We use static equilibrium and reactive transport simulations to test the hypothesis that perturbations in water chemistry associated with a CO2 gas leak into dilute groundwater are important measures for the potential release of CO2 to the atmosphere. Simulation parameters are constrained by groundwater chemistry, flow, and lithology from the High Plains aquifer. The High Plains aquifer is used to represent a typical sedimentary aquifer overlying a deep CO2 storage reservoir. Specifically, we address the relationships between CO2 flux, groundwater flow, detection time and distance. The CO2 flux ranges from 10(3) to 2 x 10(6) t/yr (0.63 to 1250 t/m(2)/yr) to assess chemical perturbations resulting from relatively small leaks that may compromise long-term storage, water quality, and surface ecology, and larger leaks characteristic of short-term well failure. Results: For the scenarios we studied, our simulations show pH and carbonate chemistry are good indicators for leakage of stored CO2 into an overlying aquifer because elevated CO2 yields a more acid pH than the ambient groundwater. CO2 leakage into a dilute groundwater creates a slightly acid plume that can be detected at some distance from the leak source due to groundwater flow and CO2 buoyancy. pH breakthrough curves demonstrate that CO2 leaks can be easily detected for CO2 flux >= 10(4) t/yr within a 15-month time period at a monitoring well screened within a permeable layer 500 m downstream from the vertical gas trace. At lower flux rates, the CO2 dissolves in the aqueous phase in the lower most permeable unit and does not reach the monitoring well. Sustained pumping in a developed aquifer mixes the CO2-affected water with the ambient water and enhances pH signal for small leaks (10(3) t/yr) and reduces pH signal for larger leaks (>= 10(4) t/yr). Conclusion: The ability to detect CO2 leakage from a storage reservoir to overlying dilute groundwater is dependent on CO2 solubility, leak flux, CO2 buoyancy, and groundwater flow. Our simulations show that the most likely places to detect CO2 are at the base of the confining layer near the water table where CO2 gas accumulates and is transported laterally in all directions, and downstream of the vertical gas trace where groundwater flow is great enough to transport dissolved CO2 laterally. Our simulations show that CO2 may not rise high enough in the aquifer to be detected because aqueous solubility and lateral groundwater transport within the lower aquifer unit exceeds gas pressure build-up and buoyancy needed to drive the CO2 gas upwards.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Transport and detection of carbon dioxide in dilute aquifers
    Carroll, Susan
    Hao, Yue
    Aines, Roger
    GREENHOUSE GAS CONTROL TECHNOLOGIES 9, 2009, 1 (01): : 2111 - 2118
  • [2] Dissolution Trapping of Carbon Dioxide in Heterogeneous Aquifers
    Soltanian, Mohamad Reza
    Amooie, Mohammad Amin
    Gershenzon, Naum
    Dai, Zhenxue
    Ritzi, Robert
    Xiong, Fengyang
    Cole, David
    Moortgat, Joachim
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2017, 51 (13) : 7732 - 7741
  • [3] Effects of Carbon Dioxide on the Mobilization of Metals from Aquifers
    Terzi, Katerina
    Aggelopoulos, Christos A.
    Bountas, Ioannis
    Tsakiroglou, Christos D.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2014, 48 (08) : 4386 - 4394
  • [4] Modeling of Carbon Dioxide Leakage from Storage Aquifers
    Heidari, Parvaneh
    Hassanzadeh, Hassan
    FLUIDS, 2018, 3 (04):
  • [5] Carbon dioxide injection into deep aquifers: A geomechanical perspective
    Laloui, L.
    Li, C.
    COMPUTER METHODS AND RECENT ADVANCES IN GEOMECHANICS, 2015, : 45 - 50
  • [6] Design of carbon dioxide storage in aquifers
    Qi, Ran
    LaForce, Tara C.
    Blunt, Martin J.
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2009, 3 (02) : 195 - 205
  • [7] Numerical study on the hydrodynamic and thermodynamic properties of compressed carbon dioxide energy storage in aquifers
    Li, Yi
    Yu, Hao
    Li, Yi
    Liu, Yaning
    Zhang, Guijin
    Tang, Dong
    Jiang, Zhongming
    RENEWABLE ENERGY, 2020, 151 : 1318 - 1338
  • [8] Storage capacity comparison of hydrogen and carbon dioxide in heterogeneous aquifers
    Bai, Fuqiao
    Jia, Cunqi
    Hu, Jinchuan
    Alsousy, Abdulhamid
    Lu, Yingda
    Sepehrnoori, Kamy
    GAS SCIENCE AND ENGINEERING, 2024, 121
  • [9] Numerical investigation of the partitioning phenomenon of carbon dioxide and multiple impurities in deep saline aquifers
    Li, Didi
    Jiang, Xi
    APPLIED ENERGY, 2017, 185 : 1411 - 1423
  • [10] Multicomponent reactive transport of carbon dioxide in fluvial heterogeneous aquifers
    Soltanian, Mohamad Reza
    Hajirezaie, Sassan
    Hosseini, Seyyed Abolfazl
    Dashtian, Hassan
    Amooie, Mohammad Amin
    Meyal, Alireza
    Ershadnia, Reza
    Ampomah, William
    Islam, Akand
    Zhang, Xiaoying
    JOURNAL OF NATURAL GAS SCIENCE AND ENGINEERING, 2019, 65 : 212 - 223