Co-optimization of CMUT and receive amplifiers to suppress effects of neighbor coupling between CMUT elements

被引:9
作者
Berg, Sigrid [1 ]
Ytterdal, Trond [1 ]
Ronnekleiv, Arne [1 ]
机构
[1] Norwegian Univ Sci & Technol, NTNU, Dept Elect & Telecommun, N-7491 Trondheim, Norway
来源
2008 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 AND APPENDIX | 2008年
关键词
CMUT; receive ampliriers; neighbor coupling;
D O I
10.1109/ULTSYM.2008.0520
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Capacitive Micromachined Ultrasound Transducers (CMUTs) promise high transducer performance for several ultrasound applications. When using the CMUT array for medical applications where a focused ultrasound image with a 90 degree image sector is needed, we need a large number of individual elements. In off-axis beam steering, neighbor elements operate at different phase. This leads to unwanted acoustic effects caused by the interaction with the fluid medium outside the array. We see high-Q resonances close to the center frequency of the array at off-axis angles, which we want to reduce. We propose to use Transimpertance Amplifiers (TIAs) and Charge Sampling Amplifiers (CSAs) where we can easily adjust the input impedance, which opens up the possibility to design amplifiers that art optimized for an ultrasound system with CMUTs. Simulations show that a low impedance path results in suppression of the effects of resonances for both CSAs and TIAs and that co-optimization is important since the frequency of the CMUT array affects the Q-factor of the unwanted resonances. Even though we introduce an impedance mismatch the noise figure is still at an acceptable level. We present simulations in water, blood plasma with estimated data, and olive oil and show that the viscosity of the medium greatly influences the presence of resonances. This indicates that effects that might be present in human tissue may be much reduced in olive oil or other vegetable oils.
引用
收藏
页码:2103 / 2106
页数:4
相关论文
共 10 条
[1]  
Bayram B, 2005, ULTRASON, P601
[2]  
Bozkurt A, 1998, ULTRASON, P1025, DOI 10.1109/ULTSYM.1998.764979
[3]  
CALOR MM, IEEE ULTR S 2004, P2073
[4]   Design of a front-end integrated circuit for 3D acoustic imaging using 2D CMUT arrays [J].
Çiçek, I ;
Bozkurt, A ;
Karaman, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2005, 52 (12) :2235-2241
[5]   Annular-ring CMUT arrays for forward-looking IVUS: Transducer characterization and imaging [J].
Degertekin, FL ;
Guldiken, RO ;
Karaman, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2006, 53 (02) :474-482
[6]  
FRANCO EE, IEEE ULTR S 2006, P2257
[7]   Ultrasonic scattering in chocolate and model systems containing sucrose, tripalmitin and olive oil [J].
Holmes, Andrew K. ;
Challis, Richard E. ;
Chen, Yinghui ;
Hibberd, David J. ;
Moates, Graham K. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2007, 54 (11) :2357-2366
[8]  
REDDY CL, 2007, INT S VLSI DES AUT T, P25
[9]  
REDDY CL, 2007, 17 GREAT LAK S VLSI, P11
[10]   CMUT army modeling through free acoustic CMUT modes and analysis of the fluid CMUT interface through fourier transform methods [J].
Ronnekleiv, A .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2005, 52 (12) :2173-2184