A competitive immunoassay for ultrasensitive detection of Hg2+ in water, human serum and urine samples using immunochromatographic test based on surface-enhanced Raman scattering

被引:43
|
作者
She, Pei [1 ]
Chu, Yanxin [1 ]
Liu, Chunwei [2 ]
Guo, Xun [2 ]
Zhao, Kang [1 ]
Li, Jianguo [1 ]
Du, Haijing [1 ]
Zhang, Xiang [1 ]
Wang, Hong [2 ]
Deng, Anping [1 ]
机构
[1] Soochow Univ, Coll Chem Chem Engn & Mat Sci, Key Lab Hlth Chem & Mol Diag Suzhou, Suzhou 215123, Peoples R China
[2] OptoTrace Suzhou Technol Inc, Suzhou 215123, Peoples R China
基金
中国国家自然科学基金;
关键词
Immunochromatographic test; Competitive immunoassay; Mercury(II) ion; Surface-enhanced Raman scattering; Colloidal gold nanoparticles; HIGHLY SENSITIVE DETECTION; GOLD NANOPARTICLES; ELECTROCHEMILUMINESCENCE DETECTION; ELECTROCHEMICAL BIOSENSOR; LABELED SSDNA; QUANTUM DOTS; TEST STRIP; IONS; MERCURY; SENSOR;
D O I
10.1016/j.aca.2015.12.021
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An immunochromatographic test (ICT) strip was developed for ultrasensitive competitive immunoassay of Hg2+. This strategy was achieved by combining the easy-operation and rapidity of ICT with the high sensitivity of surface-enhanced Raman scattering (SERS). Monoclonal antibody (mAb) against Hg2+ and Raman active substance 4-mercaptobenzoic acid (MBA) dual labelled gold nanoparticles (GNPs) were prepared as an immunoprobe. The Raman scattering intensity of MBA on the test line of the ICT strip was measured for quantitative determination of Hg2+. The ICT was able to directly detect Hg2+ without complexing due to the specific recognition of the mAb with Hg2+. The IC50 and limit of detection (LOD) of the assay for Hg2+ detection were 0.12 ng mL(-1) and 0.45 pg mL(-1), respectively. There was no cross-reactivity (CR) of the assay with other nineteen ions and the ICT strips could be kept for 5 weeks without loss of activity. The recoveries of the assay for water, human serum and urine samples spiked with Hg2+ were in range of 88.3-107.3% with the relative standard deviations (RSD) of 1.5-9.5% (n = 3). The proposed ICT was used for the detection of Hg2+ in urine samples collected from Occupational Disease Hospital and the results were confirmed by cold-vapor atomic fluorescence spectroscopy (CV-AFS). The assay exhibited high sensitivity, selectivity, stability, precision and accuracy, demonstrating a promising method for the detection of trace amount of Hg2+ in environmental water samples and biological serum and urine samples. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:139 / 147
页数:9
相关论文
共 50 条
  • [21] Ag-decorated polymer chip for the determination of the respective concentrations of TTD and Hg2+ by surface-enhanced raman scattering
    Yang, Bo
    Wang, Ye
    Jin, Sila
    Guo, Shuang
    Park, Eungyeong
    Shin, Jin Y.
    Zhang, Weiyu
    Jung, Young Mee
    ANALYST, 2022, 147 (04) : 597 - 603
  • [22] A terpyridine-based test strip for the detection of Hg2+ in various water samples and drinks
    Wang, Junjun
    Rao, Qingpeng
    Wang, Haiyan
    Zhang, Qiong
    Liu, Gang
    Wu, Zhichao
    Yu, Jianhua
    Zhu, Xiaojiao
    Tian, Yupeng
    Zhou, Hongping
    ANALYTICAL METHODS, 2019, 11 (02) : 227 - 231
  • [23] Immunoassay using surface-enhanced Raman scattering based on aggregation of reporter-labeled immunogold nanoparticles
    Ji-Wei Chen
    Yong Lei
    Xiang-Jiang Liu
    Jian-Hui Jiang
    Guo-Li Shen
    Ru-Qin Yu
    Analytical and Bioanalytical Chemistry, 2008, 392 : 187 - 193
  • [24] Rapid detection of whole active ricin using a surface-enhanced Raman scattering-based sandwich immunoassay
    Wang, Jiang
    Xu, Hua
    Luo, Li
    Li, Nannan
    Qiao, Chunxia
    Wu, Jianfeng
    Guo, Lei
    Xie, Jianwei
    JOURNAL OF RAMAN SPECTROSCOPY, 2023, 54 (02) : 137 - 149
  • [25] Selective and Quantitative Detection of Trace Amounts of Mercury(II) Ion (Hg2+) and Copper(II) Ion (Cu2+) Using Surface-Enhanced Raman Scattering (SERS)
    Tang, Wenqiong
    Chase, D. Bruce
    Sparks, Donald L.
    Rabolt, John F.
    APPLIED SPECTROSCOPY, 2015, 69 (07) : 843 - 849
  • [26] Immunoassay using surface-enhanced Raman scattering based on aggregation of reporter-labeled immunogold nanoparticles
    Chen, Ji-Wei
    Lei, Yong
    Liu, Xiang-Jiang
    Jiang, Jian-Hui
    Shen, Guo-Li
    Yu, Ru-Qin
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 392 (1-2) : 187 - 193
  • [27] Surface-enhanced resonance Raman scattering for the sensitive detection of a tuberculosis biomarker in human serum
    Owens, Nicholas A.
    Pinter, Abraham
    Porter, Marc D.
    JOURNAL OF RAMAN SPECTROSCOPY, 2019, 50 (01) : 15 - 25
  • [28] Surface-enhanced Raman Scattering-based Competitive Immunoassay of Poly-γ-D-Glutamic Acid for Highly Sensitive Detection of Anthrax Biomarker
    Ko, Juhui
    Cha, Kiweon
    Jeon, Jun Ho
    Rhie, Gi-eun
    Choi, Jonghoon
    Choo, Jaebum
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2015, 36 (03): : 822 - 826
  • [29] Surface-enhanced Raman scattering spectroscopy as a sensitive and selective technique for the detection of folic acid in water and human serum
    Stokes, Robert J.
    McBride, Eileen
    Wilson, Clive G.
    Girkin, John M.
    Smith, W. Ewen
    Graham, Duncan
    APPLIED SPECTROSCOPY, 2008, 62 (04) : 371 - 376
  • [30] Ultrasensitive Detection of Hepatotoxic Microcystin Production from Cyanobacteria Using Surface-Enhanced Raman Scattering Immunosensor
    Li, Ming
    Paidi, Santosh Kumar
    Sakowski, Eric
    Preheim, Sarah
    Barman, Ishan
    ACS SENSORS, 2019, 4 (05): : 1203 - 1210