Effect of distances between lens and sample surface on laser-induced breakdown spectroscopy with spatial confinement

被引:5
作者
Jiang, Zhenhua [1 ]
Shao, Junfeng [1 ]
Wang, Tingfeng [1 ]
Guo, Jin [1 ]
Zhang, Dan [2 ,3 ]
Chen, Anmin [2 ,3 ]
Jin, Mingxing [2 ,3 ]
机构
[1] Chinese Acad Sci, Changchun Inst Opt Fine Mech & Phys, State Key Lab Laser Interact, Matter & Innovat Lab Electroopt Countermeasures T, Changchun 130033, Jilin, Peoples R China
[2] Jilin Univ, Inst Atom & Mol Phys, Changchun 130012, Jilin, Peoples R China
[3] Jilin Univ, Jilin Prov Key Lab Appl Atom & Mol Spect, Changchun 130012, Jilin, Peoples R China
基金
中国国家自然科学基金;
关键词
laser-induced breakdown spectroscopy; LIBS; spatial confinement; distance of lens-to-sample; signal enhancement; OPTICAL-EMISSION; INDUCED PLASMAS; CU PLASMA; ABLATION; ENHANCEMENT; SPECTROMETRY; SPECTRA; ARGON;
D O I
10.1088/2058-6272/aabc5e
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
Spatial confinement can significantly enhance the spectral intensity of laser-induced plasma in air. It is attributed to the compression of plasma plume by the reflected shockwave. In addition, optical emission spectroscopy of laser-induced plasma can also be affected by the distance between lens and sample surface. In order to obtain the optimized spectral intensity, the distance must be considered. In this work, spatially confined laser-induced silicon plasma by using a Nd: YAG nanosecond laser at different distances between lens and sample surface was investigated. The laser energies were 12 mJ, 16 mJ, 20 mJ, and 24 mJ. All experiments were carried out in an atmospheric environment. The results indicated that the intensity of Si (I) 390.55 nm line firstly rose and then dropped with the increase of lens-to-sample distance. Moreover, the spectral peak intensity with spatial confinement was higher than that without spatial confinement. The enhancement ratio was approximately 2 when laser energy was 24 mJ.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Plasma shielding effect in laser ablation of metallic samples and its influence on LIES analysis
    Aguilera, JA
    Aragon, C
    Penalba, F
    [J]. APPLIED SURFACE SCIENCE, 1998, 127 : 309 - 314
  • [2] Spatial characterization of laser induced plasmas obtained in air and argon with different laser focusing distances
    Aguilera, JA
    Bengoechea, J
    Aragón, C
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (04) : 461 - 469
  • [3] DETERMINATION OF CARBON CONTENT IN STEEL USING LASER-INDUCED BREAKDOWN SPECTROSCOPY
    AGUILERA, JA
    ARAGON, C
    CAMPOS, J
    [J]. APPLIED SPECTROSCOPY, 1992, 46 (09) : 1382 - 1387
  • [4] [Anonymous], 2017, AIP ADV, DOI DOI 10.1063/1.4994983
  • [5] Comparison of plasma temperature and electron density on nanosecond laser ablation of Cu and nano-Cu
    Chen, Anmin
    Jiang, Yuanfei
    Wang, Tingfeng
    Shao, Junfeng
    Jin, Mingxing
    [J]. PHYSICS OF PLASMAS, 2015, 22 (03)
  • [6] Hot electron generation via vacuum heating process in femtosecond laser-solid interactions
    Chen, LM
    Zhang, J
    Dong, QL
    Teng, H
    Liang, TJ
    Zhao, LZ
    Wei, ZY
    [J]. PHYSICS OF PLASMAS, 2001, 8 (06) : 2925 - 2929
  • [7] Femtosecond laser ablation of copper at high laser fluence: Modeling and experimental comparison
    Cheng, C. W.
    Wang, S. Y.
    Chang, K. P.
    Chen, J. K.
    [J]. APPLIED SURFACE SCIENCE, 2016, 361 : 41 - 48
  • [8] Influence of distances between the lens and the target on the characteristic of laser induced lead plasma
    Diao, C. Y.
    Chen, C. S.
    Man, B. Y.
    Wang, C.
    Fu, H. B.
    [J]. EUROPEAN PHYSICAL JOURNAL D, 2011, 63 (01) : 123 - 128
  • [9] Physical insights of cavity confinement enhancing effect in laser-induced breakdown spectroscopy
    Fu, Yangting
    Hou, Zongyu
    Wang, Zhe
    [J]. OPTICS EXPRESS, 2016, 24 (03): : 3055 - 3066
  • [10] Ablation of solids by femtosecond lasers: Ablation mechanism and ablation thresholds for metals and dielectrics
    Gamaly, EG
    Rode, AV
    Luther-Davies, B
    Tikhonchuk, VT
    [J]. PHYSICS OF PLASMAS, 2002, 9 (03) : 949 - 957