Electrospray ionization stability and concentration sensitivity in capillary electrophoresis-mass spectrometry using a flow-through microvial interface

被引:8
|
作者
Wang, Lingyu [1 ]
Li, Yueyang [1 ]
Chen, Dazhou [2 ]
Chen, David Da Yong [1 ]
机构
[1] Univ British Columbia, Dept Chem, Vancouver, BC V6T 1Z1, Canada
[2] Natl Inst Metrol, Dept Analyt Chem & Stoichiometry, Beijing, Peoples R China
基金
加拿大自然科学与工程研究理事会;
关键词
Capillary electrophoresis‐ mass spectrometry; Concentration sensitivity; Electrospray ionization stability; Flow‐ through microvial interface; INJECTION; CE;
D O I
10.1002/elps.202000239
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Concentration sensitivity is a key performance indicator for analytical techniques including for capillary electrophoresis-mass spectrometry (CE-MS) with electrospray ionization (ESI). In this study, a flow-through microvial interface was used to couple CE with MS and improve the ESI stability and detection sensitivity. By infusing a peptide mixture through the interface into an MS detector at a typical flow rate for CE-MS analysis, the spatial region near the interface was mapped for MS signal intensity. When the sprayer tip was within a 6 x 6.5 x 5 mm region in front of the MS inlet, the ESI was stable with no significant loss of signal intensity for ions with m/z 239. Finite element simulations showed that the average electric field strength at the emitter tip did not change significantly with minor changes in emitter tip location. Experiments were conducted with four different mass spectrometer platforms coupled to CE via the flow-through microvial interface. Key performance indicators, that is, limit of detection (LOD) and linearity of calibration curves were measured for nine amino acids and five peptides. Inter- and intraday reproducibility were also tested. The results were shown to be suitable for quantification when internal standards were used.
引用
收藏
页码:360 / 368
页数:9
相关论文
共 50 条
  • [21] A simple approach to compensate the suction caused by the electrospray ionization source in capillary electrophoresis-mass spectrometry systems
    do Lago, Claudimir Lucio
    Rajh Vidal, Denis Tadeu
    Mendonca Francisco, Kelliton Jose
    dos Santos, Vagner Bezerra
    ELECTROPHORESIS, 2014, 35 (16) : 2412 - 2416
  • [22] A new high-performance interface for capillary electrophoresis electrospray ionization mass spectrometry
    Severs, JC
    Harms, AC
    Smith, RD
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1996, 10 (10) : 1175 - 1178
  • [23] A New High-performance Interface for Capillary Electrophoresis/Electrospray Ionization Mass Spectrometry
    Severs, J. C.
    Harms, A. C.
    Smith, R. D.
    Rapid Communications in Mass Spectrometry, 10 (10):
  • [24] Advantages of pressurization in capillary electrophoresis/electrospray ionization mass spectrometry
    Hau, J
    Roberts, M
    ANALYTICAL CHEMISTRY, 1999, 71 (18) : 3977 - 3984
  • [25] Determination of isoflavones by capillary electrophoresis/electrospray ionization mass spectrometry
    Aramendia, M.A.
    Borau, V.
    Garcia, I.
    Jimenez, C.
    Lafont, F.
    Marinas, M.
    Porras, A.
    Urbano, F.J.
    Journal of Mass Spectrometry, 1995, (Special):
  • [26] Determination of isoflavones by capillary electrophoresis electrospray ionization mass spectrometry
    Aramendia, MA
    Borau, V
    Garcia, I
    Jimenez, C
    Lafont, F
    Marinas, JM
    Porras, A
    Urbano, FJ
    JOURNAL OF MASS SPECTROMETRY, 1995, : S153 - S157
  • [27] IONIZATION TECHNIQUES IN CAPILLARY ELECTROPHORESIS-MASS SPECTROMETRY: PRINCIPLES, DESIGN, AND APPLICATION
    Hommerson, Paul
    Khan, Amjad M.
    de Jong, Gerhardus J.
    Somsen, Govert W.
    MASS SPECTROMETRY REVIEWS, 2011, 30 (06) : 1096 - 1120
  • [28] Quantitative Proteomics Using Ultra low Flow Capillary Electrophoresis-Mass Spectrometry
    Faserl, Klaus
    Kremser, Leopold
    Mueller, Martin
    Teis, David
    Lindner, Herbert H.
    ANALYTICAL CHEMISTRY, 2015, 87 (09) : 4633 - 4640
  • [29] CAPILLARY ELECTROPHORESIS ELECTROSPRAY-IONIZATION ION-TRAP MASS-SPECTROMETRY USING A SHEATHLESS INTERFACE
    RAMSEY, RS
    MCLUCKEY, SA
    JOURNAL OF MICROCOLUMN SEPARATIONS, 1995, 7 (05) : 461 - 469
  • [30] Differential detection of Rhizoma coptidis by capillary electrophoresis electrospray ionization mass spectrometry with a nanospray interface
    Liu, Jing-Xin
    Zhang, Yi-Wei
    Yuan, Fang
    Chen, Hong-Xu
    Zhang, Xin-Xiang
    ELECTROPHORESIS, 2014, 35 (21-22) : 3258 - 3263