Electrospray ionization stability and concentration sensitivity in capillary electrophoresis-mass spectrometry using a flow-through microvial interface

被引:8
|
作者
Wang, Lingyu [1 ]
Li, Yueyang [1 ]
Chen, Dazhou [2 ]
Chen, David Da Yong [1 ]
机构
[1] Univ British Columbia, Dept Chem, Vancouver, BC V6T 1Z1, Canada
[2] Natl Inst Metrol, Dept Analyt Chem & Stoichiometry, Beijing, Peoples R China
基金
加拿大自然科学与工程研究理事会;
关键词
Capillary electrophoresis‐ mass spectrometry; Concentration sensitivity; Electrospray ionization stability; Flow‐ through microvial interface; INJECTION; CE;
D O I
10.1002/elps.202000239
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Concentration sensitivity is a key performance indicator for analytical techniques including for capillary electrophoresis-mass spectrometry (CE-MS) with electrospray ionization (ESI). In this study, a flow-through microvial interface was used to couple CE with MS and improve the ESI stability and detection sensitivity. By infusing a peptide mixture through the interface into an MS detector at a typical flow rate for CE-MS analysis, the spatial region near the interface was mapped for MS signal intensity. When the sprayer tip was within a 6 x 6.5 x 5 mm region in front of the MS inlet, the ESI was stable with no significant loss of signal intensity for ions with m/z 239. Finite element simulations showed that the average electric field strength at the emitter tip did not change significantly with minor changes in emitter tip location. Experiments were conducted with four different mass spectrometer platforms coupled to CE via the flow-through microvial interface. Key performance indicators, that is, limit of detection (LOD) and linearity of calibration curves were measured for nine amino acids and five peptides. Inter- and intraday reproducibility were also tested. The results were shown to be suitable for quantification when internal standards were used.
引用
收藏
页码:360 / 368
页数:9
相关论文
共 50 条
  • [1] Capillary electrophoresis-mass spectrometry using a flow-through microvial interface for cationic metabolome analysis
    Lindenburg, Petrus W.
    Ramautar, Rawi
    Jayo, Roxana G.
    Chen, David D. Y.
    Hankemeier, Thomas
    ELECTROPHORESIS, 2014, 35 (09) : 1308 - 1314
  • [2] Sheathless capillary electrophoresis-mass spectrometry using a pulsed electrospray ionization source
    Chao, Bing-Fong
    Chen, Chao-Jung
    Li, Fu-An
    Her, Guor-Rong
    ELECTROPHORESIS, 2006, 27 (11) : 2083 - 2090
  • [3] Mass Transport in a Micro Flow-Through Vial of a Junction-at-the-Tip Capillary Electrophoresis-Mass Spectrometry Interface
    Zhong, Xuefei
    Maxwell, E. Jane
    Chen, David D. Y.
    ANALYTICAL CHEMISTRY, 2011, 83 (12) : 4916 - 4923
  • [4] Investigation of electrospray for a capillary electrophoresis-mass spectrometry interface in reverse polarity and negative ion mode
    Stickney, Morgan
    Xia, Qiangwei
    Amster, I. Jonathan
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2019, 25 (01) : 157 - 163
  • [5] A simple approach to compensate the suction caused by the electrospray ionization source in capillary electrophoresis-mass spectrometry systems
    do Lago, Claudimir Lucio
    Rajh Vidal, Denis Tadeu
    Mendonca Francisco, Kelliton Jose
    dos Santos, Vagner Bezerra
    ELECTROPHORESIS, 2014, 35 (16) : 2412 - 2416
  • [6] IONIZATION TECHNIQUES IN CAPILLARY ELECTROPHORESIS-MASS SPECTROMETRY: PRINCIPLES, DESIGN, AND APPLICATION
    Hommerson, Paul
    Khan, Amjad M.
    de Jong, Gerhardus J.
    Somsen, Govert W.
    MASS SPECTROMETRY REVIEWS, 2011, 30 (06) : 1096 - 1120
  • [7] Alignment of capillary electrophoresis-mass spectrometry datasets using accurate mass information
    Nevedomskaya, Ekaterina
    Derks, Rico
    Deelder, Andre M.
    Mayboroda, Oleg A.
    Palmblad, Magnus
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 395 (08) : 2527 - 2533
  • [8] CAPILLARY ELECTROPHORESIS ELECTROSPRAY-IONIZATION ION-TRAP MASS-SPECTROMETRY USING A SHEATHLESS INTERFACE
    RAMSEY, RS
    MCLUCKEY, SA
    JOURNAL OF MICROCOLUMN SEPARATIONS, 1995, 7 (05) : 461 - 469
  • [9] Analysis of microcystins by capillary zone electrophoresis coupling with electrospray ionization mass spectrometry
    Tong, Ping
    Zhang, Lan
    He, Yu
    Tang, Shurong
    Cheng, Jintian
    Chen, Guonan
    TALANTA, 2010, 82 (04) : 1101 - 1106
  • [10] Twenty years of interface development for capillary electrophoresis-electrospray ionization-mass spectrometry
    Maxwell, E. Jane
    Chen, David D. Y.
    ANALYTICA CHIMICA ACTA, 2008, 627 (01) : 25 - 33