Flat-Plate Solar Collector Thermal Performance and Optimal Operation Mode by Exergy Analysis and Numerical Simulation

被引:11
作者
Kohole, Yemeli Wenceslas [1 ,2 ]
Fohagui, Fodoup Cyrille Vincelas [1 ]
Tchuen, Ghislain [1 ,2 ]
机构
[1] Univ Dschang, UR ISIE, IUT FV Bandjoun, Dept Energet Environm & Thermal Engn, POB 134, Bandjoun, Cameroon
[2] Univ Dschang, UR 2MSP, Fac Sci, Dept Phys, POB 67, Dschang, Cameroon
关键词
Flat-plate collector; Energy; Exergy destruction; Exergy efficiency; Simulation; HEAT-TRANSFER; ENERGY; OPTIMIZATION; NANOFLUIDS;
D O I
10.1007/s13369-020-05150-w
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
In this paper, the effect of a flat-plate solar collector components exergy destruction rates on the collector performance has been examined. A theoretical model based on energy and exergy balance for glass cover, absorber plate and working fluid resulted in nonlinear ordinary differentials non-autonomous system of equations that was solved numerically. Upon verification of the accuracy of the proposed model with experimental data, the effect of parameters such as solar radiation, mass flow rate, inlet fluid temperature and insulation thickness on the exergy destruction rates and exergy efficiency has been investigated. The model was used to optimize parameters, such as inlet fluid temperature, mass flow rate and number of collector tube. The results reveal that the highest exergy destruction rate occurs in the absorber plate, which is 79.23% of the total exergy destruction rate. Increasing the mass flow rate to 0.0087 kg/s leads to a decrease in the absorber plate exergy destruction rate to a minimum value of 575.74 W/m(2) and to an increase in the exergy efficiency to a maximum value of 21.97%. When the inlet fluid temperature increases from 20 to 50 degrees C, the absorber plate exergy destruction rate reduces from 676.66 to 438.40 W/m(2) resulting in a significant increase in the collector exergy efficiency from 6.80 to 37.86%. The optimum operating condition was found to be 37 degrees C for the inlet fluid temperature, 0.0087 kg/s for mass flow rate and fifteen for the number of tubes.
引用
收藏
页码:1877 / 1897
页数:21
相关论文
共 39 条
[1]   Analog model of dynamics of a flat-plate solar collector [J].
Aleksiejuk, Joanna ;
Chochowski, Andrzej ;
Reshetiuk, Volodymyr .
SOLAR ENERGY, 2018, 160 :103-116
[2]   Effect analysis on energetic, exergetic and financial performance of a flat plate collector with heat pipes [J].
Allouhi, A. ;
Benzakour Amine, M. .
ENERGY CONVERSION AND MANAGEMENT, 2019, 195 :274-289
[3]   Forced-circulation solar water heating system using heat pipe-flat plate collectors: Energy and exergy analysis [J].
Allouhi, A. ;
Benzakour Amine, M. ;
Buker, M. S. ;
Kousksou, T. ;
Jamil, A. .
ENERGY, 2019, 180 :429-443
[4]  
Bejan A, 2006, ADV ENG THERMODYNAMI, Vthird
[5]   Economic optimization of low-flow solar domestic hot waterplants [J].
Cardinale, N ;
Piccininni, F ;
Stefanizzi, P .
RENEWABLE ENERGY, 2003, 28 (12) :1899-1914
[6]   Experimental investigation of energy and exergy performance of square and circular solar ponds [J].
Dehghan, Ali A. ;
Movahedi, Alireza ;
Mazidi, Mohsen .
SOLAR ENERGY, 2013, 97 :273-284
[7]   Modelling of a flat-plate solar collector using artificial neural networks for different working fluid (water) flow rates [J].
Diez, F. J. ;
Navas-Gracia, L. M. ;
Martinez-Rodriguez, A. ;
Correa-Guimaraes, A. ;
Chico-Santamarta, L. .
SOLAR ENERGY, 2019, 188 :1320-1331
[8]  
Dincer I, 2007, EXERGY ENERGY ENV SU, V1
[9]  
Duffie JA, 2013, SOLAR ENGINEERING OF THERMAL PROCESSES, 4TH EDITION, P1, DOI 10.1002/9781118671603
[10]   Thermal-hydraulic characteristics and exergy performance in tube-on-sheet flat plate solar collectors: Effects of nanofluids and mixed convection [J].
Edalatpour, Mojtaba ;
Solano, Juan P. .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2017, 118 :397-409