Immunoassay platform with surface-enhanced resonance Raman scattering for detecting trace levels of SARS-CoV-2 spike protein

被引:23
作者
Bistaffa, Maria J. [1 ]
Camacho, Sabrina A. [1 ,2 ]
Pazin, Wallance M. [2 ,3 ]
Constantino, Carlos J. L. [3 ]
Oliveira, Osvaldo N., Jr. [2 ]
Aoki, Pedro H. B. [1 ]
机构
[1] Sao Paulo State Univ UNESP, Sch Sci Humanities & Languages, BR-19806900 Assis, SP, Brazil
[2] Univ Sao Paulo, Sao Carlos Inst Phys, IFSC, BR-13566590 Sao Carlos, SP, Brazil
[3] Sao Paulo State Univ UNESP, Sch Technol & Appl Sci, BR-19060900 Presidente Prudente, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Conjugation in gold nanoparticles; Resonant Raman molecules; Silica shell functionalization; SARS-CoV-2; antibodies; SARS-CoV-2 spike protein detection; SERRS immunoassay Platform; METHYLENE-BLUE; GOLD; FLUORESCENCE; NANOPARTICLES;
D O I
10.1016/j.talanta.2022.123381
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The early diagnosis of Coronavirus disease (COVID-19) requires either an accurate detection of genetic material or a sensitive detection of viral proteins. In this work, we designed an immunoassay platform for detecting trace levels of SARS-CoV-2 spike (S) protein. It is based on surface-enhanced resonance Raman scattering (SERRS) of methylene blue (MB) adsorbed onto spherical gold nanoparticles (AuNPs) and coated with a 6 nm silica shell. The latter shell in the SERRS nanoprobe prevented aggregation and permitted functionalization with SARS-CoV-2 antibodies. Specificity of the immunoassay was achieved by combining this functionalization with antibody immobilization on the cover slides that served as the platform support. Different concentrations of SARS-CoV-2 antigen could be distinguished and the lack of influence of interferents was confirmed by treating SERRS data with the multidimensional projection technique Sammon's mapping. With SERRS using a laser line at 633 nm, the lowest concentration of spike protein detected was 10 pg/mL, achieving a limit of detection (LOD) of 0.046 ng/mL (0.60 pM). This value is comparable to the lowest concentrations in the plasma of COVID-19 patients at the onset of symptoms, thus indicating that the SERRS immunoassay platform may be employed for early diagnosis.
引用
收藏
页数:9
相关论文
共 82 条
[11]   Immunoassay quantification using surface-enhanced fluorescence (SEF) tags [J].
Camacho, S. A. ;
Sobral-Filho, R. G. ;
Aoki, P. H. B. ;
Constantino, C. J. L. ;
Brolo, A. G. .
ANALYST, 2017, 142 (15) :2717-2724
[12]   Increasing the Enhancement Factor in Plasmon-Enhanced Fluorescence with Shell-Isolated Nanoparticles [J].
Camacho, S. A. ;
Aoki, P. H. B. ;
Albella, P. ;
Oliveira, Osvaldo N., Jr. ;
Constantino, C. J. L. ;
Aroca, R. F. .
JOURNAL OF PHYSICAL CHEMISTRY C, 2016, 120 (37) :20530-20535
[13]   The efficiency of photothermal action of gold shell-isolated nanoparticles against tumor cells depends on membrane interactions [J].
Camacho, Sabrina A. ;
Kobal, Mirella B. ;
Moreira, Lucas G. ;
Bistaffa, Maria J. ;
Roque, Thamires C. ;
Pazin, Wallance M. ;
Toledo, Karina A. ;
Oliveira Jr, Osvaldo N. ;
Aoki, Pedro H. B. .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2022, 211
[14]   Molecular-level effects on cell membrane models to explain the phototoxicity of gold shell-isolated nanoparticles to cancer cells [J].
Camacho, Sabrina A. ;
Kobal, Mirella B. ;
Almeida Jr, Alexandre M. ;
Toledo, Karina A. ;
Oliveira Jr, Osvaldo N. ;
Aoki, Pedro H. B. .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2020, 194
[15]   Zika Immunoassay Based on Surface-Enhanced Raman Scattering Nanoprobes [J].
Camacho, Sabrina A. ;
Sobral-Filho, Regivaldo Gomes ;
Aoki, Pedro Henrique B. ;
Constantino, Carlos Jose L. ;
Brolo, Alexandre G. .
ACS SENSORS, 2018, 3 (03) :587-594
[16]   Co-Deposition of Gold Nanoparticles and Metalloporphyrin Using the Langmuir Blodgett (LB) Technique for Surface-Enhanced Raman Scattering (SERS) [J].
Camacho, Sabrina A. ;
Aoki, Pedro H. B. ;
de Assis, Francisco F. ;
Pires, Ana M. ;
de Oliveira, Kleber T. ;
Aroca, Ricardo F. ;
Constantino, Carlos J. L. .
APPLIED SPECTROSCOPY, 2015, 69 (04) :451-456
[17]   Saliva-based COVID-19 detection: A rapid antigen test of SARS-CoV-2 nucleocapsid protein using an electrical-double-layer gated field-effect transistor-based biosensing system [J].
Chen, Pin-Hsuan ;
Huang, Chih-Cheng ;
Wu, Chia-Che ;
Chen, Po-Hsuan ;
Tripathi, Adarsh ;
Wang, Yu-Lin .
SENSORS AND ACTUATORS B-CHEMICAL, 2022, 357
[18]   Sensitivity of Chest CT for COVID-19: Comparison to RT-PCR [J].
Fang, Yicheng ;
Zhang, Huangqi ;
Xie, Jicheng ;
Lin, Minjie ;
Ying, Lingjun ;
Pang, Peipei ;
Ji, Wenbin .
RADIOLOGY, 2020, 296 (02) :E115-E117
[19]   Detection and quantitative analysis of carbendazim herbicide on Ag nanoparticles via surface-enhanced Raman scattering [J].
Furini, Leonardo Negri ;
Sanchez-Cortes, Santiago ;
Lopez-Tocon, Isabel ;
Carlos Otero, Juan ;
Aroca, Ricardo F. ;
Leopoldo Constantino, Carlos Jose .
JOURNAL OF RAMAN SPECTROSCOPY, 2015, 46 (11) :1095-1101
[20]   ELECTROMAGNETIC THEORY OF ENHANCED RAMAN-SCATTERING BY MOLECULES ADSORBED ON ROUGH SURFACES [J].
GERSTEN, J ;
NITZAN, A .
JOURNAL OF CHEMICAL PHYSICS, 1980, 73 (07) :3023-3037