Performance parameters of a standalone PV plant

被引:39
作者
El Fathi, Amine [1 ]
Nkhaili, Lahcen [1 ]
Bennouna, Amin [1 ]
Outzourhit, Abdelkader [1 ]
机构
[1] Cadi Ayyad Univ, Fac Sci Semlalia, LPSCM, Marrakech, Morocco
关键词
PV plant; Performance ratio; Droop mode; Yields; Isolated grid; DISTRIBUTED GENERATION TECHNOLOGIES; RURAL ELECTRIFICATION; POWER-SYSTEMS; HYBRID;
D O I
10.1016/j.enconman.2014.05.045
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this work we present a detailed description of a 7.2 kWp photovoltaic power plant installed in the remote rural village Elkaria (province of Essaouira in Morocco). This plant supplies 16 households with electricity through a local grid that was installed for this purpose. The results of monitoring some performance parameters of the plant such as load curve, the yields and the performance ratio are presented and discussed. The performance ratio of the PV plant varied between 33% and 70.2%. The low values of this parameter are mainly attributed to the way the battery inverter manages the energy flow. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:490 / 495
页数:6
相关论文
共 28 条
[1]   Optimum utilization of renewable energy sources in a remote area [J].
Akella, A. K. ;
Sharma, M. P. ;
Saini, R. P. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2007, 11 (05) :894-908
[2]   Optimised model for community-based hybrid energy system [J].
Ashok, S. .
RENEWABLE ENERGY, 2007, 32 (07) :1155-1164
[3]   Economic evaluation of hybrid renewable energy systems for rural electrification in Iran-A case study [J].
Asrari, Arash ;
Ghasemi, Abolfazl ;
Javidi, Mohammad Hossein .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2012, 16 (05) :3123-3130
[4]  
Bahraoui-Buret J., 1983, GISEMENT SOLAIRE MAR
[5]  
Britich Standard, 1998, 61724 BS EN
[6]   Modeling of hybrid renewable energy systems [J].
Deshmukh, M. K. ;
Deshmukh, S. S. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2008, 12 (01) :235-249
[7]   Distributed generation technologies and optimization [J].
Dulau, Lucian Ioan ;
Abrudean, Mihail ;
Bica, Dorin .
7TH INTERNATIONAL CONFERENCE INTERDISCIPLINARITY IN ENGINEERING (INTER-ENG 2013), 2014, 12 :687-692
[8]   Comparative evaluation of different power management strategies of a stand-alone PV/Wind/PEMFC hybrid power system [J].
Dursun, Erkan ;
Kilic, Osman .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2012, 34 (01) :81-89
[9]   Parametric study of hybrid (wind plus solar plus diesel) power generating systems [J].
Elhadidy, M ;
Shaahid, SM .
RENEWABLE ENERGY, 2000, 21 (02) :129-139
[10]   Supplementing demand management programs with distributed generation options [J].
Fahrioglu, Murat ;
Alvarado, F. L. ;
Lasseter, R. H. ;
Yong, T. .