Energetic and economic evaluation of membrane-based carbon capture routes for power plant processes

被引:32
作者
Maas, P. [1 ]
Nauels, N. [2 ]
Zhao, L. [3 ]
Markewitz, P. [3 ]
Scherer, V. [1 ]
Modigell, M. [2 ]
Stolten, D. [3 ]
Hake, J. -F. [3 ]
机构
[1] Ruhr Univ Bochum, Dept Energy Plant Technol, Univ Str 150, D-44780 Bochum, Germany
[2] Rhein Westfal TH Aachen, Mech Proc Engn, Aachener Verfahrenstech AVT, Turmstr 46, D-52056 Aachen, Germany
[3] Forschungszentrum Julich, Inst Energy & Climate Res, D-52425 Julich, Germany
关键词
Carbon capture and storage (CCS); Economic evaluation; Membranes; Oxyfuel; Pre-combustion CO2-capture; Post-combustion CO2-capture; POLYMER MEMBRANES; DIOXIDE CAPTURE; CO2; SEPARATION; PILOT-PLANT; COMBUSTION; IGCC; PERFORMANCE; INTEGRATION; SIMULATION; PEROVSKITE;
D O I
10.1016/j.ijggc.2015.11.018
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The application of CCS technology involves considerable efficiency losses and significant additional investments. The aim is therefore to reduce these efficiency losses and to cut costs. Against this background, membrane-based carbon capture routes for the post-combustion, oxyfuel and pre-combustion technology lines will be analyzed in the following for hard-coal-fired power plants. To the best knowledge of the authors, this paper is the first one comparing membrane based capture routes on common technical and economic boundary conditions. The post-combustion process involves a cascade arrangement of polymer membranes. In the optimum case, the efficiency losses for this concept amount to 9.6 percentage points. In comparison, efficiency losses for the other two membrane-based concepts, i.e. oxyfuel (oxygen transport membrane (OTM) with vacuum pump) and pre-combustion (water-gas shift reactor-WGSMR), are considerably lower (5.3/5.5 percentage points). The main goal of this paper is to assess levelized cost of electricity (LCOE) for the process routes under consideration and their sensitivity on CO2 allowance costs, yearly operating hours, membrane costs and membrane lifetime. The specific investment costs for the capture plants are 2410(sic)/kWh (oxyfuel), 2572(sic)/kW h (post-combustion) and 2660(sic)/kWh (pre-combustion). This is 66% (post-combustion), 55% (oxyfuel) and 33% (pre-combustion) above the specific investment costs for the corresponding reference case without carbon capture. Allowance prices in a range from (sic)20 (pre-combustion) to (sic)39 (post-combustion) per tonne of CO2 would be necessary to compensate for the additional investments. Since it can be assumed that the membranes have a limited lifetime, the influence on electricity generation costs was calculated for different lifetimes. The results show that a technical service life of more than 3 years does not have a significant impact on generation costs. This applies to all the technological concepts investigated. In terms of LCOE and CO2 avoidance costs ((sic)/t(co2)) it turns out that oxyfuel and pre-combustion based membrane power plants are favorable compared to the post-combustion route. However, it has to be kept in mind that the uncertainty in membrane costs are higher for the oxyfuel membranes (ceramic oxygen transport membranes) and the pre-combustion membranes (microporous ceramic membranes) compared to the polymeric post-combustion membranes which already have achieved a commercial level. (C) 2015 Published by Elsevier Ltd.
引用
收藏
页码:124 / 139
页数:16
相关论文
共 58 条
[31]   Operation Experiences of Oxyfuel Power Plant in Callide Oxyfuel Project [J].
Komaki, Akihiro ;
Gotou, Takahiro ;
Uchida, Terutoshi ;
Yamada, Toshihiko ;
Kiga, Takashi ;
Spero, Chris .
12TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, GHGT-12, 2014, 63 :490-496
[32]  
Konstantin P., 2007, PRAXISBUCH ENERGIWIR
[33]   Assessment of oxy-fuel, pre- and post-combustion-based carbon capture for future IGCC plants [J].
Kunze, Christian ;
Spliethoff, Hartmut .
APPLIED ENERGY, 2012, 94 :109-116
[34]   Oxygen permeability and phase stability of Ba0.5Sr0.5Co0.8Fe0.2O3-δ perovskite at intermediate temperatures [J].
Li, Xiaoyu ;
Kerstiens, Thomas ;
Markus, Torsten .
JOURNAL OF MEMBRANE SCIENCE, 2013, 438 :83-89
[36]   A parametric study of the impact of membrane materials and process operating conditions on carbon capture from humidified flue gas [J].
Low, Bee Ting ;
Zhao, Li ;
Merkel, Timothy C. ;
Weber, Michael ;
Stolten, Detlef .
JOURNAL OF MEMBRANE SCIENCE, 2013, 431 :139-155
[37]   The role of membranes in post-combustion CO2 capture [J].
Luis, Patricia ;
Van der Bruggen, Bart .
GREENHOUSE GASES-SCIENCE AND TECHNOLOGY, 2013, 3 (05) :318-337
[38]   Lignite fired IGCC with ceramic membranes for CO2 separation [J].
Maas, Pascal ;
Scherer, Viktor .
12TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, GHGT-12, 2014, 63 :1976-1985
[39]  
Matthes F., 2012, WIRTSCHAFTLICHKEIT K
[40]   Carbon dioxide capture with membranes at an IGCC power plant [J].
Merkel, Tim C. ;
Zhou, Meijuan ;
Baker, Richard W. .