HPLC-DAD Method for Simultaneous Determination of Dipyrone (Metamizole) and Caffeine in Tablets and Identification of Major Degradation Product by Direct Infusion ESI-MS

被引:11
作者
Vieira, James Cabral [1 ]
Sversut, Rubia Adriele [1 ]
Maciel, Isadora Theodoro [1 ]
Hellmann Carollo, Aline Regina [1 ]
do Amaral, Marcos Serrou [2 ]
Kassab, Najla Mohamad [1 ]
机构
[1] Univ Fed Mato Grosso do Sul, Fac Pharmaceut Sci Food & Nutr, Lab Pharmaceut Technol, Av Costa e Silva S-N, BR-79070900 Campo Grande, MS, Brazil
[2] Univ Fed Mato Grosso do Sul, Inst Phys, Av Costa e Silva S-N, BR-79070900 Campo Grande, MS, Brazil
关键词
High-performance liquid chromatography; Quality control; Caffeine; Dipyrone; 4-Methylaminoantipyrine; Validation method; LIQUID-CHROMATOGRAPHY; WASTE-WATER; DRUGS;
D O I
10.1007/s10337-017-3263-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new chromatographic method for simultaneous determination of dipyrone (metamizole) and caffeine in tablets was developed and validated. Excellent resolution and quantification were obtained using a reverse-phase Acclaim (R) C18 column (250.0 x 4.6 mm; 5.0 mu m particles) with acetonitrile/water (65: 35 v/v) as mobile phase, adjusted to pH 7.5 using drops of water: triethylamine (99: 1 v/v). The elution mode was isocratic with flow rate of 1.0 mL min(-1), and ultraviolet (UV) detection was performed at 273 nm. The ranges of linearity for dipyrone and caffeine were 5.0-35.0 and 1.0-7.0 mu g mL(-1), respectively. Intra-and interday precision showed relative standard deviation (RSD) < 2% and analysis of variance (ANOVA) p value > 0.05, respectively. The method proved to be precise, sensitive, and exact with low limits of detection and quantification and average recovery of 99.3 and 100.8%. The factorial model of Youden was used to analyze the robustness of the method, while identification of critical factors was conducted by two-tailed t test with 95% confidence interval. The method was shown to be selective, detecting presence of analytes in degradation products originating from study of hydrolytic stability at different pH values (5.0, 6.0, 7.0, and 9.0) at room temperature. Identification of product degradation by direct injection electrospray ionization (ESI) mass spectroscopy (MS) revealed the presence of a fragment ion at m/z 187 and ions corresponding to [M + H]+ and [M + Na]+ at m/z 218 and 240, respectively, confirming the identity of the 4-methylaminoantipyrine product related to dipyrone.
引用
收藏
页码:489 / 495
页数:7
相关论文
共 14 条
[11]   Rapid, simple and accurate liquid chromatography-diode array detection validated method for the determination of dipyrone in solid and liquid dosage forms [J].
Senyuva, HZ ;
Aksahin, I ;
Ozcan, S ;
Kabasakal, BV .
ANALYTICA CHIMICA ACTA, 2005, 547 (01) :73-77
[12]   Guidance for robustness/ruggedness tests in method validation [J].
Vander Heyden, Y ;
Nijhuis, A ;
Smeyers-Verbeke, J ;
Vandeginste, BGM ;
Massart, DL .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 24 (5-6) :723-753
[13]  
Youden W.J., 1975, STAT TECHNIQUES COLL
[14]   Determination of methylxanthines in urine by liquid chromatography with diode array UV detection [J].
Zambonin, CG ;
Aresta, A ;
Palmisano, F .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 36 (03) :621-624