Characterization of a modular microfluidic photoionization detector

被引:11
作者
Rezende, Gustavo Coelho [1 ]
Le Calve, Stephane [2 ,3 ]
Brandner, Jurgen J. [4 ]
Newport, David [1 ]
机构
[1] Univ Limerick, Sch Engn, Bernal Inst, Limerick V94 T9PX, Ireland
[2] Unistra, Inst Chim & Procede Energie Environm & Sante, Grp Atmospher Phys Chem, ICPEES,UMR 7515,CNRS, 25 Rue Becquerel, F-67087 Strasbourg 02, France
[3] In Air Solut, 25 Rue Becquerel, F-67000 Strasbourg, France
[4] Karlsruhe Inst Technol, Inst Microstruct Technol IMT, Karlsruhe, Germany
基金
欧盟地平线“2020”;
关键词
Photoionization detector; Miniaturization; Microfabrication; Gas chromatography; VOC detection; Air quality; GAS-CHROMATOGRAPHY; EXPOSURE; LEVEL; GC;
D O I
10.1016/j.snb.2020.128667
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Photoionization detectors with a small ionization chamber can contribute to overall gas analyser miniaturization. This work reports the characterization of a microfluidic photoionization detector prototype (mu PID) which is constructed to be modular for easy replacement of the components and maintenance. The device is fabricated by micromilling and electrical discharge machining, dispensing clean room fabrication techniques. The mu PID ionization chamber is a microchannel and four channel designs are presented and tested in experiments in order to evaluate the influence of the geometrical parameters on the detector performance. The chamber volumes of the channel designs range from 1.1 to 6.7 mu L. Experimental characterization of the prototype is performed when it is used without and with a portable gas chromatograph (GC) for volatile organic compounds (VOCs) analysis. When a sample of 100 ppm toluene is injected directly into the mu PID, it can generate a current signal up to similar to 4 nA. When used without a GC, the device showed a linear response for an injection of toluene gas concentrations ranging from 1 to 100 ppm. A combination of high illumination area and electrode area resulted in the highest signal in the mu PID with a detection limit of similar to 40 ppb of toluene. When integrated to the portable GC, the detection limit reached for toluene is similar to 140 ppb. The detection limit for toluene was further reduced to low ppb levels (similar to 5 ppb) when a preconcentrator was integrated into the sampling loop of the portable GC.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Micro Milled Microfluidic Photoionization Detector for Volatile Organic Compounds
    Rezende, Gustavo C.
    Le Calve, Stephane
    Brandner, Juergen J.
    Newport, David
    MICROMACHINES, 2019, 10 (04)
  • [2] Photoionization detector for portable rapid GC
    Peng, F. M.
    Xie, P. H.
    Shi, Y. G.
    Wang, J. D.
    Liu, W. Q.
    Liu, H. Y.
    CHROMATOGRAPHIA, 2007, 65 (5-6) : 331 - 336
  • [3] Photoionization Detector for Portable Rapid GC
    F. M. Peng
    P. H. Xie
    Y. G. Shi
    J. D. Wang
    W. Q. Liu
    H. Y. Li
    Chromatographia, 2007, 65 : 331 - 336
  • [4] Field evaluation of a portable photoionization detector for assessing exposure to solvent mixtures
    Coy, JD
    Bigelow, PL
    Buchan, RM
    Tessari, JD
    Parnell, JO
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 2000, 61 (02): : 268 - 274
  • [5] The performance of pulsed discharge helium photoionization detector for organic compounds
    Liang, B
    Li, C
    Li, RY
    Ou, QY
    Yu, WL
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (04) : 546 - 550
  • [6] Integrated microfluidic helium discharge photoionization detectors
    Li, Maxwell Wei-Hao
    Ghosh, Abhishek
    Sharma, Ruchi
    Zhu, Hongbo
    Fan, Xudong
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 332
  • [7] SELECTIVE DETERMINATION OF TRACE ARSENIC AND ANTIMONY SPECIES IN NATURAL-WATERS BY GAS-CHROMATOGRAPHY WITH A PHOTOIONIZATION DETECTOR
    YAMAMOTO, M
    TANAKA, S
    HASHIMOTO, Y
    APPLIED ORGANOMETALLIC CHEMISTRY, 1992, 6 (04) : 351 - 356
  • [8] Operating the pulsed discharged detector in both the electron-capture and photoionization modes within the same GC analysis
    Wentworth, WE
    Huang, J
    Chen, ECM
    Stearns, SD
    CHROMATOGRAPHIA, 1996, 43 (7-8) : 353 - 360
  • [9] Managing photon flux in a miniaturized photoionization detector
    Meyer, Mackenzie
    Huang, Xiaheng
    Fan, Xudong
    Kushner, Mark J.
    JOURNAL OF APPLIED PHYSICS, 2024, 135 (14)
  • [10] Development of a Novel Micro Photoionization Detector for Rapid Volatile Organic Compounds Measurement
    Zhou, Qi
    Zhang, Sixiang
    Zhang, Xu
    Ma, Xu
    Zhou, Wei
    APPLIED BIONICS AND BIOMECHANICS, 2018, 2018