High-rate gamma spectroscopy

被引:0
|
作者
Westphal, GP
机构
来源
关键词
high-rate gamma spectroscopy; preloaded filter; gated integrator; high-purity Germanium detector;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An overview is given of high-rate gamma spectroscopy as it is related to the field of activation analysis of short-lived isomeric transitions. The transistor reset preamplifier is a prerequisite for HRGS and gives optimum performance together with n-type HPGe detectors. Gated integrators are replaced as pulse processors for HRGS by the recently developed Preloaded Filter. A digital implementation of the PLF guarantees very good resolution, excellent stability and high throughput rate without A/D-conversion dead-time.
引用
收藏
页码:57 / 65
页数:9
相关论文
共 50 条
  • [1] High-rate Germanium Gamma Spectroscopy: A Sensitivity Study
    Gilbert, Andrew J.
    Fast, James E.
    Myjak, Mitchell J.
    VanDevender, Brent A.
    Wood, Lynn S.
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [2] PERFORMANCE OF A HIGH-RATE GAMMA-SPECTROSCOPY SYSTEM
    WESTPHAL, GP
    NUCLEAR INSTRUMENTS & METHODS, 1976, 138 (03): : 467 - 470
  • [3] HIGH-RATE GAMMA-SPECTROSCOPY AND RELATED PROBLEMS
    WESTPHAL, GP
    JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1981, 61 (1-2): : 111 - 119
  • [4] DIGITAL SIGNAL-PROCESSING FOR HIGH-RATE GAMMA-RAY SPECTROSCOPY
    DRNDAREVIC, V
    RYGE, P
    GOZANI, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 277 (2-3): : 532 - 536
  • [5] ACTIVATION-ANALYSIS WITH A HIGH-RESOLUTION HIGH-RATE GAMMA-SPECTROSCOPY SYSTEM
    GRASS, F
    JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1982, 70 (1-2): : 411 - 425
  • [6] A digital pulse processor for high-rate high-resolution X and gamma-ray spectroscopy
    Alberti, R.
    Frizzi, T.
    Moser, S.
    Abba, A.
    Geraci, A.
    Caponio, F.
    Baruzzi, P.
    Ripamonti, G.
    Bombelli, L.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 858 - 861
  • [7] REFINING A HIGH-RATE GAMMA-SPECTROMETRY SYSTEM
    WESTPHAL, GP
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1994, 179 (01): : 45 - 54
  • [8] SDDs for high-rate and high-resolution electron spectroscopy
    Nava, A.
    Biassoni, M.
    Pozzi, S.
    Carminati, M.
    Lechner, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1046
  • [9] A novel VLSI processor for high-rate, high resolution spectroscopy
    Pullia, A
    Fiorini, C
    Gatti, E
    Longoni, A
    Buttler, W
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 439 (2-3): : 385 - 390
  • [10] HIGH-RATE GAMMA SPECTROSCOPY SYSTEM FOR ACTIVATION-ANALYSIS OF SHORT-LIVED ISOMERIC TRANSITIONS
    WESTPHAL, GP
    NUCLEAR INSTRUMENTS & METHODS, 1976, 136 (02): : 271 - 283